Introducing our advanced TCU (Temperature Control Unit), a pivotal solution designed for efficient temperature management in industrial processes. As a leading supplier in China, our factory leverages existing thermal energy infrastructure, including high-temperature thermal oil, steam, cooling water, and ultra-low temperature media. This innovative unit seamlessly integrates into your control system or secondary circuit, ensuring precise temperature control for reactors and reaction kettles. Experience optimal heat transfer capabilities with our TCU, tailored to enhance your process efficiency and reliability. Choose us as your trusted partner in temperature control solutions

    Product Feature

    A complete Temperature Control Unit (TCU) typically consists of the following components and operates according to a specific workflow.

    1. Core Components
    • Circulation Pump: Drives the heat transfer fluid to circulate between the TCU and the user's equipment.
    • Heater: Typically electric heating elements, used to precisely heat the fluid when heat is required.
    • Heat Exchangers:
      • Cooling Heat Exchanger: Transfers excess heat from the process fluid to a cooling medium, such as cooling water or a cryogenic fluid.
      • Steam Heat Exchanger: (If a steam heat source is used).
    • Control System: The "brain" of the unit. It includes temperature sensors, a PID controller, and a Human-Machine Interface (HMI) for setting and maintaining the target temperature.
    • Expansion Tank: Accommodates the volumetric expansion and contraction of the fluid due to temperature changes, thereby stabilizing system pressure.
    2. Typical Workflow
    • Heating Mode: When the process requires heating, the TCU activates the circulation pump and the heater. The heat transfer fluid is heated to the set temperature and then pumped into the reactor jacket or coil.
    • Cooling Mode: When the reaction is exothermic or cooling is required, the TCU turns off the heater and opens the valve for the cooling water or cryogenic medium. The heat is removed from the fluid via the heat exchanger, and the cooled fluid is pumped back to the reactor to lower its temperature.
    • Temperature Maintenance Mode: The PID controller dynamically adjusts the input of both heating and cooling to maintain a constant temperature.
    Key Advantages of TCUs
    🎯
    High-Precision Control

    Capable of achieving temperature control accuracy of ±0.5°C or even higher.

    🌡️
    Wide Temperature Range

    Depending on the fluid used, the operating range can span from -120°C (using special fluids) to +400°C (using thermal oil).

    🔒
    High Safety

    A closed-loop system prevents the fluid from contacting the atmosphere, reducing the risks of oxidation and contamination.

    🔁
    Improved Process Reproducibility

    Precise temperature control is key to ensuring product quality and batch-to-batch consistency.

    ⚡
    Increased Efficiency

    Compared to directly feeding steam and cooling water to a reactor jacket, a TCU offers faster response times, more stable control, and lower energy consumption.

    Application Scenarios

    Beyond chemical reactors, TCUs are widely used in:

    💊 Pharmaceutical Industry Temperature control for synthesis reactions, crystallization, and fermenters.
    🔋 New Energy Battery material production and fuel cell testing.
    🏭 Plastics and Rubber Mold temperature control, and for extruders and calenders.
    🔬 Laboratories Precise temperature control for small-scale reactors, bioreactors, viscometers, and other equipment.
    16
    15
    14
    Flowchart
    tcu
    Specification
    Parameter UNIT MODEL
    TCU-20 TCU-30 TCU-40 TCU-50 TCU-75
    Temp control range ℃ Based on the temperature of the heat source and cold source provided by the customer
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil or water
    Heating method / Indirect Heating or direct heating
    Cooling method / Indirect Cooling or direct cooling
    Alarm function / Pump reversal / Overload / Abnormal heating
    Heating power m² Non standard customization
    Cooling power m² Non standard customization
    Motor power KW 1.5 2.2 3 4 5.5
    Pump flow m³/h 6 10 12.5 16 25
    Pump head m 28 28 30 32 35
    Power Input KW 1.5 2.2 3 4 5.5
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil or water pipe Inch 1" 1" 1-1/4" 1-1/2" 2"
    Size (L×W×H) mm Non-standard integrated design
    Products Detail
    tcu1
    tcu2
    Frequently Asked Questions (FAQ)
    What is a Temperature Control Unit (TCU) and how does it work?
    A Temperature Control Unit (TCU) is a closed-loop system that precisely controls the temperature of process equipment such as reactors, molds, or bioreactors. It works by circulating a heat transfer fluid (water or thermal oil) through the equipment, using heaters to raise the temperature and heat exchangers to lower it, all regulated by a PID controller.
    What temperature range can a TCU achieve?
    Depending on the heat transfer medium selected, a TCU can operate across a very wide range — from as low as -120°C using special cryogenic fluids, up to +400°C using thermal oil. The specific range for each unit is based on the heat source and cold source conditions provided by the customer.
    What is the temperature control accuracy of your TCU models?
    Our TCU models utilize PID control technology to achieve a temperature control accuracy of ±1°C as standard, with high-precision configurations capable of reaching ±0.5°C or better, ensuring consistent and repeatable process results.
    What heat transfer media are compatible with the TCU?
    The TCU is compatible with both thermo-conductive oil and water as heat transfer media. The choice depends on the required temperature range and the specific application. Thermal oil is recommended for high-temperature applications, while water is suitable for moderate-temperature processes.
    Can the TCU be customized for specific industrial requirements?
    Yes. Our TCU systems support non-standard customization for heating power, cooling power, and overall dimensions (L×W×H). The integrated design can be tailored to meet specific process requirements across industries including pharmaceuticals, new energy, plastics, rubber, and laboratory applications.
    What safety features are built into the TCU?
    The TCU includes multiple built-in alarm and protection functions, including pump reversal detection, motor overload protection, and abnormal heating alerts. The closed-loop design also prevents the heat transfer fluid from contacting the atmosphere, minimizing risks of oxidation, contamination, and fluid degradation.