A TCU (Temperature Control Unit) is a temperature control unit that, by utilizing existing thermal energy infrastructure (such as high-temperature thermal oil, steam, cooling water, ultra-low temperature media), integrates into the control system or secondary circuit system used to control process equipment temperature. This allows the heat transfer medium to achieve cold/heat energy transfer in reactors or reaction kettles.

    Product Feature

    A complete Temperature Control Unit (TCU) typically consists of the following components and operates according to a specific workflow
    1. Core Components
    • Circulation Pump: Drives the heat transfer fluid to circulate between the TCU and the user's equipment.
    • Heater: Typically electric heating elements, used to precisely heat the fluid when heat is required.
    • Heat Exchangers:
    • Cooling Heat Exchanger: Transfers excess heat from the process fluid to a cooling medium, such as cooling water or a cryogenic fluid.
    • Steam Heat Exchanger: (If a steam heat source is used).
    • Control System: The "brain" of the unit. It includes temperature sensors, a PID controller, and a Human-Machine Interface (HMI) for setting and maintaining the target temperature.
    • Expansion Tank: Accommodates the volumetric expansion and contraction of the fluid due to temperature changes, thereby stabilizing system pressure.
    2. Typical Workflow
    • Heating Mode: When the process requires heating, the TCU activates the circulation pump and the heater. The heat transfer fluid is heated to the set temperature and then pumped into the reactor jacket or coil.
    • Cooling Mode: When the reaction is exothermic or cooling is required, the TCU turns off the heater and opens the valve for the cooling water or cryogenic medium. The heat is removed from the fluid via the heat exchanger, and the cooled fluid is pumped back to the reactor to lower its temperature.
    • Temperature Maintenance Mode: The PID controller dynamically adjusts the input of both heating and cooling to maintain a constant temperature.

    Key Advantages of TCUs

    • High-Precision Control: Capable of achieving temperature control accuracy of ±0.5°C or even higher.
    • Wide Temperature Range: Depending on the fluid used, the operating range can span from -120°C (using special fluids) to +400°C (using thermal oil).
    • High Safety: A closed-loop system prevents the fluid from contacting the atmosphere, reducing the risks of oxidation and contamination.
    • Improved Process Reproducibility: Precise temperature control is key to ensuring product quality and batch-to-batch consistency.
    • Increased Efficiency: Compared to directly feeding steam and cooling water to a reactor jacket, a TCU offers faster response times, more stable control, and lower energy consumption.

    Application Scenarios (Additional Examples)

    Beyond chemical reactors, TCUs are widely used in:
    Pharmaceutical Industry: Temperature control for synthesis reactions, crystallization, and fermenters.
    New Energy: Battery material production and fuel cell testing.
    Plastics and Rubber: Mold temperature control, and for extruders and calenders.
    Laboratories: Precise temperature control for small-scale reactors, bioreactors, viscometers, and other equipment.
    16
    15
    14

    Flowchart

    tcu

    specification

    Parameter UNIT MODEL
    TCU-20 TCU-30 TCU-40 TCU-50 TCU-75
    Temp control range ℃ Based on the temperature of the heat source and cold source provided by the customer
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil or water
    Heating method / Indirect Heating or direct heating
    Cooling method / Indirect Cooling or direct cooling
    Alarm function / Pump reversal/Overload/Abnormal heating
    Heating power m2 Non standard customization
    Cooling power m2 Non standard customization
    Motor power KW 1.5 2.2 3 4 5.5
    Pump flow m³/h 6 10 12.5 16 25
    Pump head m 28 28 30 32 35
    Power Input KW 1.5 2.2 3 4 5.5
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil or water pipe Inch 1" 1" 1-1/4" 1-1/2" 2"
    Size(LxWxH) mm Non-standard integrated design