0102030405
Industrial Water Cooled Screw Chiller Suppliers and Factory in China - High Efficiency Cooling Solutions
Machine Future
❄
Temperature Range
-80℃ to 35℃
⚡
Power Range
Cooling Power 100KW - 1500KW
⚙
High-Efficiency Compressor
High efficiency imported high quality screw compressor, such as Hanbell, Bitzer, etc.
🔄
Evaporator & Condenser
Shell and tube evaporator and condenser, high efficiency, stable operation
🏷
Premium Components
OMRON, FUJI, TE, LG, ABB, SIEMENS and other brand accessories
🛡
Self-Diagnostic System
Perfect safety protection and fault display system, no professional person needed for repair and maintenance
💻
PLC Control
PLC control, high reliability, strong anti-interference ability. Explosion-proof design of electric control cabinet and pipeline
🔒
Safety Features
High and low voltage protection, phase sequence protection, Overload Protection, Medium Liquid Level Monitoring, etc.
📶
Special Features
Remote communication function (TCP/RTU), Explosion proof design
Core Features & Advantages
Compared to centrifugal and scroll compressors, screw compressors demonstrate irreplaceable advantages in industrial applications:
✔ 1. Outstanding Reliability and Durability:
• Robust Construction: The meshing movement of the twin screw rotors involves pure metal contact. With no reciprocating parts, wear is minimal, vibration is low, and service life is extended.
• High Tolerance to Liquid Slugging: Insensitive to minor liquid flood-back, capable of adapting to rapid load changes, making it suitable for industrial sites with significant load fluctuations.
✔ 2. Wide-Ranging and Efficient Capacity Modulation:
• Continuous Modulation: Utilizing a sliding vane (slide valve) mechanism, it enables continuous capacity control from 10% to 100%, offering high efficiency at part-load conditions—ideal for matching the variable thermal loads of industrial production lines.
• Excellent Start-Up Characteristics: Typically equipped with star-delta or soft starters, minimizing grid impact.
✔ 3. Superior Stability and Adaptability:
• Smooth Operation: Continuous compression ensures stable output and high precision in water temperature control.
• Broad Refrigerant Compatibility: Suitable not only for conventional R134a and R410A but also for natural working fluids like Ammonia (R717) and Propane (R290), meeting special industrial requirements.
✔ 4. Ease of Maintenance:
• Fewer major moving parts result in longer maintenance intervals. Core components (e.g., bearings, shaft seals) can be serviced on-site without factory return, minimizing downtime.
Typical System Composition
A typical industrial water-cooled screw chiller features a system enhanced beyond standard configurations:
⚙ Core Four Components:
1. Screw Compressor: Typically employs twin-screw, semi-hermetic, or open-type designs. Industrial units often feature multiple compressor circuits in parallel (e.g., 2, 3, or 4 compressors) for redundancy and finer capacity control.
2. Water-Cooled Shell-and-Tube Condenser: Utilizes high-efficiency heat transfer tubes for enhanced heat dissipation. Industrial designs incorporate a larger fouling factor allowance.
3. Dry-Expansion or Flooded Evaporator:
- Dry-Expansion Evaporator: Commonly used for standard temperature ranges, easier to maintain.
- Flooded Evaporator: Offers higher heat transfer efficiency (typically 5-8% higher than dry-expansion), often used in large or high-efficiency units, but demands more sophisticated oil return design.
- Dry-Expansion Evaporator: Commonly used for standard temperature ranges, easier to maintain.
- Flooded Evaporator: Offers higher heat transfer efficiency (typically 5-8% higher than dry-expansion), often used in large or high-efficiency units, but demands more sophisticated oil return design.
4. Expansion Device: Electronic Expansion Valves (EXV) are mainstream, providing precise control. Large units may use orifice plates or thermal expansion valve assemblies.
⚡ Industrial-Grade Auxiliary Systems:
• High-Efficiency Oil Separator and Oil Management System: Multi-stage, high-efficiency oil separators ensure reliable oil return, which is critical for stable screw compressor operation.
• Enhanced Electrical Control System: Employs industrial-grade PLC controllers with comprehensive sensor monitoring (pressure, temperature, oil level, current), fault diagnostics, integration capabilities, and remote communication interfaces (Modbus, BACnet).
• Multi-Layer Protection System: Beyond basic protections, special emphasis is placed on oil pressure differential protection, oil temperature protection, and motor winding over temperature protection.
🏭 Primary Application Scenarios
Covers virtually all industrial sectors requiring stable, continuous, and high-capacity process cooling:
• Manufacturing: Plastic injection molding & extrusion (mold cooling), die-casting, automotive manufacturing (paint line, welding equipment cooling).
• Chemical & Pharmaceutical: Reactor vessel cooling, distillation condensation, process gas cooling, cleanroom environmental control.
• Central Air Conditioning Cooling Source: Comfort cooling for large factory workshops and logistics centers.
• Food & Beverage: Fermentation tank cooling, production line cooling, central kitchens.
• Energy & Metallurgy: Equipment cooling water systems, auxiliary equipment cooling.
Application Industries
Industrial refrigeration, central air conditioning systems, data centers, ship building industry, etc;
Schematic Diagram
Specification
| ITEM | UNIT | TCS-140WS | TCS-180WS | TCS-260WS | TCS-340WS | TCS-410WS | TCS-470WS | TCS-510WS | TCS-580WS | TCS-710WS | TCS-790WS | TCS-830WS | TCS-930WS | |
| Cooling Capacity | kcal/h | 103458 | 135794 | 197800 | 269524 | 321124 | 382184 | 403512 | 478504 | 5788608 | 746571 | 805141 | 298474 | |
| kW | 120.3 | 157.9 | 230 | 313.4 | 373.4 | 444.4 | 469.2 | 556.4 | 672.8 | 868 | 936 | 1045 | ||
| Total Power Input | kW | 28.5 | 36.1 | 52.4 | 67.7 | 83 | 96.4 | 101.7 | 118.7 | 142.5 | 157 | 167 | 185 | |
| Maximum Running Current | A | 91 | 121 | 171 | 220 | 268 | 310 | 336 | 377 | 453 | 498 | 534 | 620 | |
| Refrigerant | R22/R407C | |||||||||||||
| Steps Control | % | 0/33/66/100 | 0/25/50/75/100 | |||||||||||
| Temperature Control Range | ℃ | +5-+35 | ||||||||||||
| Control Type | Siemens PLC Automatic Control, Color LCD Touch Screen | |||||||||||||
| Power Supply Type | 3N, 380V.50Hz | |||||||||||||
| Safety Protection Device | Overload, Inverse Phase, High/Low Pressure, Safety Valve, Water Flow, Oil Level, Exhaust Temperature, Antifreeze Protection, etc. | |||||||||||||
| Compressor | Type | / | Semi-hermetic Screw | |||||||||||
| Start Type | / | Y-△ | ||||||||||||
| Amount | Sets | 1 | ||||||||||||
| Condenser | Type | / | Shell And Tube Type | |||||||||||
| Water Flow | m³/h | 26 | 34 | 49 | 67 | 80 | 98 | 100 | 118 | 143 | 187 | 201 | 225 | |
| Water Pressure Drop | kPa | 95 | 95 | 98 | 35 | 35 | 35 | 35 | 35 | 35 | 95 | 95 | 95 | |
| In/Out Pipe Size | DN | 65 | 80 | 80 | 100 | 125 | 125 | 125 | 125 | 150 | 150 | 200 | 200 | |
| Evaporator | Type | / | Dry Shell And Tube Type | Flood type | ||||||||||
| Water Flow | m³/h | 21 | 27 | 40 | 54 | 64 | 76 | 81 | 96 | 116 | 149 | 161 | 180 | |
| Water Pressure Drop | kPa | 85 | 85 | 85 | 32 | 32 | 32 | 32 | 32 | 32 | 90 | 90 | 90 | |
| In/Out Pipe Size | DN | 86 | 80 | 80 | 130 | 125 | 125 | 125 | 125 | 150 | 150 | 200 | 200 | |
| LxWxH | cm | 266*71*142 | 267*78*154 | 292*81*169 | 297*91*184 | 328*91*189 | 330*99*195 | 330*99*201 | 356*108*210 | 358*113*225 | 376*118*230 | 379*127*238 | ||
| Net Weight | kg | 970 | 1130 | 1460 | 1790 | 2060 | 2320 | 2490 | 2770 | 3310 | 3392 | 3050 | 2060 | |
| Refrigerant Charge | kg | 23 | 30 | 43 | 59 | 70 | 84 | 89 | 105 | 127 | 156 | 168 | 187 | |
Products Detail
Frequently Asked Questions
Q: What is the operating temperature range of this industrial screw chiller?
The unit offers a broad temperature range from -80℃ to 35℃, making it suitable for both ultra-low temperature chemical processing and standard industrial cooling operations.
Q: Which compressor brands are integrated into these chillers?
Our systems utilize high-efficiency imported semi-hermetic screw compressors from world-leading brands such as Hanbell and Bitzer to guarantee optimal energy efficiency and continuous running stability.
Q: Can the chiller be integrated into an automated Building Management System (BMS)?
Yes, the unit is fitted with a Siemens PLC control system supporting industrial remote communication protocols such as Modbus TCP/RTU and BACnet, allowing seamless integration into automated factory setups.
Q: What are the differences between dry-expansion and flooded evaporators in this series?
Dry-expansion evaporators are standard, cost-effective, and easy to maintain. Flooded evaporators, offered on larger models (such as TCS-790WS and above), provide 5-8% higher heat transfer efficiency for maximum cooling performance.
Q: Is explosion-proof customization available for hazardous environments?
Yes, we provide explosion-proof design options for electrical control cabinets and pipelines, making the unit compliant and safe for chemical, pharmaceutical, and offshore oil and gas sectors.
Q: What safety systems protect the compressor against sudden failures?
The chiller incorporates multi-tier protections including high/low pressure monitoring, phase sequence protection, oil differential pressure, oil temperature limiters, anti-freeze detection, and motor winding over-temperature sensors.