Leave Your Message

Industrial Water Cooled Screw Chiller

Screw chillers get their name because they use screw compressors. lts refrigeration power is greater than scroll chiller. According to the different way of heat dissipation, it can be divided into water cooling, air cooling and evaporation cooling screw chiller.

Water - cooled screw chiller mainly consists of compressor, evaporator, condenser, freezing parts, electric control system and so on. It will be equipped with additional auxiliary equipment for heat transfer to provide water cooling screw. The circulating cooling water required by type ll chiller. Supporting auxiliary equipment includes: cooling tower, circulating water pump, double layer stainless steel insulation water tank.

    Machine Future

    1.Temperature Range:-80℃-35℃; 
    2.Power Range: CoolingPower100KW-1500KW; 
    3.High efficiency imported high quality screw compressor, such as handbell, bitzer etc.
    4.Shell and tube evaporator and condenser, high efficiency, stable operation
    5.OMRON, FUJI, TE, LG, ABB, SIEMENS and other brand accessories
    6.Perfect safety protection and fault display system,no professional person needed for repair and maintenance
    7.PLC control, high reliability, strong anti-interference ability Explosion-proof design of electric control cabinet and pipeline
    8. Safety Features: high and low voltage protection, phase sequence 
    protection, Overload Protection, Medium Liquid Level Monitoring, etc; 
    9.Special Features: Remote communication function (TCP/RTU), Explosion proof design.

    Core Features & Advantages 

    Compared to centrifugal and scroll compressors, screw compressors demonstrate irreplaceable advantages in industrial applications:
    1. Outstanding Reliability and Durability:
    • Robust Construction: The meshing movement of the twin screw rotors involves pure metal contact. With no reciprocating parts, wear is minimal, vibration is low, and service life is extended.
    • High Tolerance to Liquid Slugging: Insensitive to minor liquid flood-back, capable of adapting to rapid load changes, making it suitable for industrial sites with significant load fluctuations.
    2.  Wide-Ranging and Efficient Capacity Modulation:
    • Continuous Modulation:Utilizing a sliding vane (slide valve) mechanism, it enables continuous capacity control from 10% to 100%, offering high efficiency at part-load conditions—ideal for matching the variable thermal loads of industrial production lines.
    • Excellent Start-Up Characteristics:Typically equipped with star-delta or soft starters, minimizing grid impact.
    3.  Superior Stability and Adaptability:
    • Smooth Operation:Continuous compression ensures stable output and high precision in water temperature control.
    • Broad Refrigerant Compatibility:Suitable not only for conventional R134a and R410A but also for natural working fluids like Ammonia (R717) and Propane (R290), meeting special industrial requirements.
    4. Ease of Maintenance:
    • Fewer major moving parts result in longer maintenance intervals. Core components (e.g., bearings, shaft seals) can be serviced on-site without factory return, minimizing downtime.

    Typical System Composition 

    A typical industrial water-cooled screw chiller features a system enhanced beyond standard configurations:
    Core Four Components:
    1. Screw Compressor:Typically employs twin-screw, semi-hermetic, or open-type designs. Industrial units often feature multiple compressor circuits in parallel (e.g., 2, 3, or 4 compressors) for redundancy and finer capacity control.
    2. Water-Cooled Shell-and-Tube Condenser:Utilizes high-efficiency heat transfer tubes for enhanced heat dissipation. Industrial designs incorporate a larger fouling factor allowance.
    3. Dry-Expansion or Flooded Evaporator:
    Dry-Expansion Evaporator:Commonly used for standard temperature ranges, easier to maintain.
    Flooded Evaporator:Offers higher heat transfer efficiency (typically 5-8% higher than dry-expansion), often used in large or high-efficiency units, but demands more sophisticated oil return design.
    4.Expansion Device: Electronic Expansion Valves (EXV) are mainstream, providing precise control. Large units may use orifice plates or thermal expansion valve assemblies.
    Industrial-Grade Auxiliary Systems:
    High-Efficiency Oil Separator and Oil Management System: Multi-stage, high-efficiency oil separators ensure reliable oil return, which is critical for stable screw compressor operation.
    Enhanced Electrical Control System:Employs industrial-grade PLC controllers with comprehensive sensor monitoring (pressure, temperature, oil level, current), fault diagnostics, integration capabilities, and remote communication interfaces (Modbus, BACnet).
    Multi-Layer Protection System:Beyond basic protections, special emphasis is placed on oil pressure differential protection, oil temperature protection, and motor winding over temperature protection
    Primary Application Scenarios
    • Covers virtually all industrial sectors requiring stable, continuous, and high-capacity process cooling:
    • Manufacturing:Plastic injection molding & extrusion (mold cooling), die-casting, automotive manufacturing (paint line, welding equipment cooling).
    • Chemical & Pharmaceutical:Reactor vessel cooling, distillation condensation, process gas cooling, cleanroom environmental control.
    • Central Air Conditioning Cooling Source: Comfort cooling for large factory workshops and logistics centers.
    • Food & Beverage: Fermentation tank cooling, production line cooling, central kitchens.
    • Energy & Metallurgy: Equipment cooling water systems, auxiliary equipment cooling.

    Application Industries

    Industrial refrigeration, central air conditioning systems, data centers, ship building industry, etc; 
    16
    15
    14

    Schematic Diagram

    Schematic Diagram

    specification

    ITEM UNIT TCS- 140WS TCS- 180WS TCS- 260WS TCS- 340WS TCS- 410WS TCS- 470WS TCS- 510WS TCS- 580WS TCS- 710WS TCS- 790WS TCS- 830WS TCS- 930WS
    Cooling Capacity kcal/h 103458 135794 197800 269524 321124 382184 403512 478504 5788608 746571 805141 298474
    kW 120.3 157.9 230 313.4 373.4 444.4 469.2 556.4 672.8 868 936 1045
    Toral Power Input kW 28.5 36.1 52.4 67.7 83 96.4 101.7 118.7 142.5 157 167 185
    Maximum Running Current A 91 121 171 220 268 310 336 377 453 498 534 620
    Refrigerant R22/R407C
    Steps Control % 0/33/66/100 0/25/50/75/100
    Temperature Control Range ℃ +5-+35
    Control Type Siemens PLC Automatic Control, Color LCD Touch Screen
    Power Supply Type 3N, 380V.50Hz
    Safety Protection Device Overload、Inverse Phase、High/Low Pressure、Safety Valve、Water Flow Oi Level、Exhaust Temperature Antifreeze Protection, etc
    Compressor Type / Semi-hermetic Screw
    Start Type / Y-△
    Amount Sels 1
    Condenser Type / Shell And Tube Type
    Water Flow m³/h 26 34 49 67 80 98 100 118 143 187 201 225
    Water Pressure Drop kPa 95 95 98 35 35 35 35 35 35 95 95 95
    In/Out Pipe Size DN 65 80 80 100 125 125 125 125 150 150 200 200
    Evaporator Type / Dry Shell And Tube Type Flood type
    Water Flow m³/h 21 27 40 54 64 76 81 96 116 149 161 180
    Water Pressure Drop kPa 85 85 85 32 32 32 32 32 32 90 90 90
    In/Out Pipe Size DN 86 80 80 130 125 125 125 125 150 150 200 200
    LxWxH cm 266*71*142 267*78*154 292*81*169 297*91*184 328*91*189 330*99*195 330*99*201 356*108*210 358*113*225 376*118*230 379*127*238
    Net weight kg 970 1130 1460 1790 2060 2320 2490 2770 3310 3392 3050 2060
    Refrigerant Charge kg 23 30 43 59 70 84 89 105 127 156 168 187

    Products Detail

    HG9A2138
    HG9A2140
    HG9A2141

    Leave Your Message