Leave Your Message

Industrial Water Cooled Chillers from China Suppliers | Reliable Factory Solutions for Process Cooling

,

Discover top-quality industrial water-cooled chillers from leading suppliers in China. Our heavy-duty refrigeration systems are engineered for continuous and precise process cooling, making them ideal for demanding manufacturing environments. With robust construction and high-efficiency components, these chillers are designed to deliver reliable temperature control for your industrial equipment. Our factory offers customization options to meet your specific operational requirements, ensuring optimal performance and efficiency.

,

    Product Feature
    ⭐ Engineered with imported premium components and advanced control systems for maximum reliability and energy efficiency.
    • Adopt compressor imported from Europe and America
    • The copper pipe adopts oxygen free welding method
    • RS485 communication function to realize automatic management (optional)
    • Imported advanced components with long service life
    • Siemens, SCHNEIDER, LG, MOELLER, West is adopted for electrical appliances
    • Control mode: imported microcomputer or PLC control (optional)
    • Perfect safety protection, fault display, repair and maintenance without professional personnel
    • High efficiency evaporator and condenser can save energy by more than 30%
    Main Types

    Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:

    1 Standard Temperature Type
    • Outlet Temperature: Typically > 5°C
    • Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
    2 Low-Temperature Type
    • Outlet Temperature: Typically ranging from -20°C to +5°C
    • Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
    • Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
    3 Explosion-Proof Type
    • Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
    • Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
    4 Corrosion-Resistant Type
    • Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
    • Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
    Key Components & Industrial-Grade Features

    Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:

    01 Compressor
    • Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
    • Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
    02 Heat Exchangers (Evaporator / Condenser)
    • Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
    • Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
    03 Control System
    • Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
    • Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
    04 Protection Systems
    • Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
    Typical Industrial Applications
    🏭
    Plastics Industry

    Cooling for injection molding machine molds, directly impacting product quality and cycle time.

    ⚗️
    Chemical & Pharmaceutical

    Cooling exothermic reactions in process vessels, controlling reaction rates and safety.

    🔧
    Machining & Lasers

    Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.

    🍔
    Food & Beverage

    Cooling for mixing, fermentation, and packaging processes in production lines.

    💡
    Electronics Industry

    Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.

    ⚡
    Energy & Metallurgy

    Transformer oil cooling, blast furnace auxiliary system cooling.

    16
    15
    14
    Schematic Diagram
    Schematic Diagram
    Specification
    Parameter / Model 03WS 05WS 06WS 08WS 10WD 12WS 15WD 20WD 25WS 30WF 40WF 50WD
    Refrigeration Capacity kW 7.7 14.2 8.98 18.95 28.4 33.5 37.9 58.2 67 75.8 116.4 135.6
    ×10⁴kcal/hr 0.66 1.22 1.45 1.63 2.44 2.88 3.26 5 5.76 6.52 10.01 11.66
    Consumed Power (kW) 2.49 3.81 4.29 5.29 7.62 8.78 10.98 15.34 17.95 21.96 30.28 35.50
    Running Amp (A) 4.73 7.79 7.76 10.9 15.58 17.1 22.6 32.38 33.26 45.2 64.06 65.82
    Compressor Number 1 1 1 1 2 1 2 2 1 4 4 2
    Power (kW) 1.94 3.26 3.74 4.74 6.52 7.68 9.48 13.14 15.75 18.96 26.28 31.5
    Current (A) 3.63 6.69 6.66 9.80 13.38 14.90 19.6 27.98 28.86 39.2 55.96 57.72
    Refrigerant Type R22 R410A R22 R410A
    Control Mode External Balance Type Thermal Expansion Valve
    Pump Type High-Efficiency Low-Noise Centrifugal Pump
    Power (kW) 0.55 0.55 0.55 0.55 1.1 1.1 1.5 2.2 2.2 3 4 4
    Current (A) 1.1 1.1 1.1 1.1 2.2 2.2 3 4.4 4.4 6 8.1 8.1
    Head (m) 22 21 21 20.5 25.5 24.5 23.5 27.5 27 33 29 29
    Condenser Water Pipe DN25 DN40 DN50 DN65
    Water Flow Rate (m³/h) 1.73 3.11 3.70 4.25 6.22 7.32 8.51 12.74 14.99 17.01 25.47 29.99
    Evaporator Water Pipe DN25 DN40   DN50 DN65
    Water Flow Rate (m³/h) 1.40 2.55 3.06 3.44 5.10 5.99 6.87 10.47 12.28 13.75 20.95 24.56
    Size Length (mm) 900 900 900 1300 1300 1450 1450 1800 1800 2200 2500 2500
    Width (mm) 650 650 650 800 800 900 900 1000 1000 1350 1350 1350
    Height (mm) 1090 1090 1090 1750 1750 1750 1750 1800 1800 1400 1800 1800
    Tank Volume (L) 50 75 90 120 120 160 160 250 300 300 500 500
    Total Weight (kg) 150 220 260 310 360 450 650 850 1050 1250 1350 1400
    Products Detail
    Industrial Water Cooled Chiller (1)
    Industrial Water Cooled Chiller (4)
    Industrial Water Cooled Chiller (2)
    Industrial Water Cooled Chiller (3)
    Frequently Asked Questions (FAQ)
    Q What is the difference between a standard temperature and a low-temperature industrial water-cooled chiller?
    A standard temperature chiller delivers outlet water temperatures above 5°C and is suitable for general industrial cooling such as injection molding and laser equipment. A low-temperature chiller operates between -20°C and +5°C using two-stage compression or cascade refrigeration cycles, and is designed for applications like pharmaceutical reactions, food quick-freezing, and low-temperature laboratory environments.
    Q What compressor types are used in industrial water-cooled chillers?
    Industrial water-cooled chillers commonly use screw compressors imported from Europe and America, valued for their stability, durability, and wide modulation range. Centrifugal compressors are employed for very large capacity requirements. For redundancy, multiple compressors in parallel are often used so that the system continues to operate even if one unit fails.
    Q How much energy can the high-efficiency evaporator and condenser save?
    The high-efficiency evaporator and condenser design used in these industrial chillers can reduce energy consumption by more than 30% compared to conventional designs. This is achieved through optimized heat transfer surfaces and advanced refrigerant circuit engineering.
    Q Are these chillers suitable for use in hazardous or corrosive environments?
    Yes. The explosion-proof type features fully explosion-proof electrical components to prevent ignition in environments with flammable gases or dust, such as petrochemical plants and painting workshops. The corrosion-resistant type uses stainless steel or special anti-corrosion materials for its casing, heat exchangers, and piping, making it suitable for electroplating shops, chemical plants, and high-salinity offshore environments.
    Q What control and communication options are available?
    These chillers support imported microcomputer or PLC control (optional), featuring advanced touchscreen HMIs with remote monitoring, fault display, data logging, and energy management. RS485 communication is available (optional) for integration with production line control systems such as SCADA and DCS, enabling fully automated management without the need for professional maintenance personnel on-site.
    Q What safety protection features are included in the industrial water-cooled chiller?
    The chillers are equipped with a comprehensive protection system that goes beyond standard high/low pressure and overcurrent protection. Additional safeguards include oil pressure differential protection, freeze protection, low-flow protection, and phase protection. Fault codes are displayed directly on the control panel, allowing operators to identify and address issues quickly, even without specialized technical expertise.