0102030405
Industrial Water Cooled Chiller from China Suppliers - Reliable Cooling Solutions for Factories
⚙️ Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
🗂️ Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
🌡️ 1. Standard Temperature Type
- Outlet Temperature: Typically > 5°C
- Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
❄️ 2. Low-Temperature Type
- Outlet Temperature: Typically ranging from -20°C to +5°C
- Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
- Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
🔥 3. Explosion-Proof Type
- Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
- Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
🛡️ 4. Corrosion-Resistant Type
- Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
- Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
🔩 Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
⚙️ 1. Compressor
- Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
- Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
🔄 2. Heat Exchangers
- Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
- Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
🖥️ 3. Control System
- Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault logging, data logging, and energy management.
- Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
🛡️ 4. Protection Systems
- Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
🏭 Typical Industrial Applications
🧱
Plastics Industry: Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical: Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔬
Machining & Lasers: Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍔
Food & Beverage: Cooling for mixing, fermentation, and packaging processes in production lines.
💻
Electronics Industry: Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy: Transformer oil cooling, blast furnace auxiliary system cooling.
📐 Schematic Diagram
📋 Specification
| Parameter Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×10⁴kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power (kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp (A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power (kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current (A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Control Mode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power (kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current (A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head (m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length (mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width (mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height (mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume (L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight (kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
🖼️ Products Detail
❓ Frequently Asked Questions (FAQ)
Q What is the difference between a standard temperature and a low-temperature industrial water-cooled chiller?
A standard temperature chiller typically delivers outlet water above 5°C and is used for general cooling applications such as injection molding and laser equipment. A low-temperature chiller operates between -20°C and +5°C, using two-stage compression or cascade refrigeration cycles, and is designed for pharmaceutical, chemical, or food quick-freezing applications that require sub-zero cooling.
Q What type of compressor is used in industrial water-cooled chillers?
Industrial water-cooled chillers commonly use screw compressors for their stability, durability, and wide modulation range. For very large capacity requirements, centrifugal compressors are used. Some large low-temperature models employ cascade compressor systems. Multiple compressors are often installed in parallel to ensure redundancy and uninterrupted operation.
Q Can the chiller be integrated with existing factory automation systems?
Yes. The control system features advanced PLCs with touchscreen HMIs and supports RS485 communication. It can be seamlessly integrated with production line control systems such as SCADA and DCS platforms, enabling remote monitoring, fault alerts, data logging, and energy management for fully automated operation.
Q Which industries are best suited for industrial water-cooled chillers?
Industrial water-cooled chillers are widely used across plastics and rubber manufacturing, chemical and pharmaceutical processing, CNC machining and laser cutting, food and beverage production, electronics and semiconductor fabrication, as well as energy and metallurgical industries including transformer cooling and blast furnace auxiliary systems.
Q What safety protection features are included?
The units are equipped with comprehensive protection systems including high and low pressure protection, overcurrent protection, oil pressure differential protection, freeze protection, low-flow protection, and phase protection. Fault codes are displayed on the control panel, allowing maintenance without the need for professional technicians in most cases.
Q Are corrosion-resistant or explosion-proof models available?
Yes. Corrosion-resistant models feature stainless steel or specially treated anti-corrosion materials for the casing, heat exchangers, and piping, making them suitable for electroplating, chemical plants, and high-humidity environments. Explosion-proof models use fully certified explosion-proof electrical components and are designed for use in petrochemical plants, coal mines, and painting workshops where flammable gases or dust may be present.