0102030405
Industrial Water Cooled Chiller from China Suppliers - High-Efficiency Solutions for Factory Process Cooling
Product Feature
Adopt compressor imported from Europe and America;
The copper pipe adopts oxygen free welding method;
RS485 communication function to realize automatic management(optional);
Imported advanced components with long service life;
Siemens SCHNEIDER.LG.MOELLER. Westis adopted for electrical appliances;
Control mode: imported microcomputer or PLC control (optional);
Perfect safety protection, fault display, repair and maintenance without professional personnel;
High efficiency evaporator and condenser can save energy by more than 30%.
Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
1. Standard Temperature Type
Outlet Temperature:
Typically > 5°C
Applications:
Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
2. Low-Temperature Type
Outlet Temperature:
Typically ranging from -20°C to +5°C
Features:
Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
Applications:
Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
3. Explosion-Proof Type
Features:
All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
Applications:
Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
4. Corrosion-Resistant Type
Features:
The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
Applications:
Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
1. Compressor
Types:
Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
Redundancy:
Multiple compressor parallel design is common, ensuring continued operation if one fails.
2. Heat Exchangers (Evaporator/Condenser)
Design:
Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
Materials:
May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
3. Control System
Intelligence:
Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
Integration:
Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
4. Protection Systems
Comprehensive:
Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
Typical Industrial Applications
• Plastics Industry:
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
• Chemical & Pharmaceutical:
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
• Machining & Lasers:
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
• Food & Beverage:
Cooling for mixing, fermentation, and packaging processes in production lines.
• Electronics Industry:
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
• Energy & Metallurgy:
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×104kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power(kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp(A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power(kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current(A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Controlmode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power(kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current(A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head(m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| WaterFlowRate(m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| WaterFlowRate(m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length(mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width(mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height(mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume(L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight(kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
Products Detail
Frequently Asked Questions (FAQ)
What is the difference between standard and low-temperature industrial chillers?
Standard temperature chillers typically provide outlet water temperatures above 5°C, making them ideal for injection molding, laser equipment, and central air systems. Low-temperature chillers operate from -20°C to +5°C using two-stage compression and specialized refrigerants, designed for chemical crystallization, pharmaceutical kettles, and food freezing.
Where should explosion-proof industrial chillers be applied?
Explosion-proof chillers are designed with sealed, spark-free electrical components (motors, switches, and controllers) to ensure safe operation in hazardous environments containing flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
How do the high-efficiency components contribute to energy saving?
Our chillers utilize imported compressors from leading European and American brands, combined with oversized shell-and-tube evaporators and condensers. This advanced design optimizes heat transfer efficiency, enabling energy savings of more than 30% compared to standard systems.
What communication and control system options are available?
The units feature advanced PLC or microcomputer control systems with touchscreens. They also support optional RS485 communication interfaces, allowing seamless integration with factory automation and primary control systems (like SCADA or DCS) for remote monitoring and data logging.
What built-in safety protections do these chillers offer?
To ensure safe and reliable operation under harsh industrial conditions, our chillers are equipped with high/low pressure protection, overcurrent protection, oil pressure differential protection, freeze protection, low-flow protection, phase protection, and an automatic fault display.