0102030405
High-Quality Oil Temperature Controller from China Suppliers | Factory Direct Heating Solutions for Industrial Applications
Machine Future
- Return oil temperature display
- Heating power gear adjustment
- Start up automatic exhaust
- PC board self-optimization microprocessor, PID automatic adjustment, simple
- By-pass pressure relief loop for hot oil
- The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
- Imported electrical accessories — WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
- Perfect safety protection and fault display system
- Professional personnel needed for repair and maintenance
⚙ Optional Features
- Multi-point temperature control unit can be customized professionally
- RS485 communication for automatic management
- PLC control, high reliability, strong anti-interference ability
- Time switch machine, cooling shut down function
- Blow back function
- Explosion-proof design of electric control cabinet and pipeline
Core Working Principle and System Composition
Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium:
1. Operating Cycle
- High-Temperature Media Circulation: A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
- High-Temperature Heat Output: The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
- Oil Return & Temperature Control: After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
2. Core System Components (Enhanced Design)
🔧 High-Temperature Heating System:
- Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
- Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
- High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
- High-Temperature Control System — Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
- Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
🛡 Safety & Auxiliary Systems (Critical):
- Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
- Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
- Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
- Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
| Temp control range | ℃ | Inlet water temperature +45℃–180℃ | ||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Thermo conductive oil | ||||
| Cooling method | / | Indirect Cooling | ||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m³/h | 6 | 6 | 10 | 14 | 16 |
| Pump head | m | 18 | 18 | 20 | 18 | 20 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Expansion tank capacity | L | 20 | 20 | 20 | 30 | 50 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating oil pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size (L×W×H) | mm | 850×325×700 | 850×325×700 | 850×325×700 | 1170×450×950 | 1500×500×1100 |
Products Detail
Frequently Asked Questions (FAQ)
What is the maximum operating temperature of this thermal oil temperature control unit?
The unit supports a temperature control range from inlet water temperature +45°C up to 180°C, with high-temperature configurations capable of reaching up to 350°C or higher depending on the selected thermal oil and system design.
What type of heat transfer medium is used in the system?
The system uses thermo conductive oil (thermal oil) as the heat transfer medium. The specific oil grade is selected based on the maximum operating temperature, thermal stability, and safety requirements — common models include L-QB and L-QC.
What safety protection features are built into the unit?
The unit is equipped with comprehensive safety protections including pump reversal alarm, oil shortage alarm, overheating protection, overload protection, oil overflow alarm, abnormal heating detection, phase loss/reverse phase protection, and an independent mechanical thermostat for over-temperature safety.
Can the unit be integrated into an automated production management system?
Yes. The unit optionally supports RS485 communication for automatic management, as well as PLC control with high reliability and strong anti-interference capability, making it suitable for integration into modern automated production lines.
What models are available and how do they differ in heating power?
Five standard models are available: SOS-05 (6 KW), SOS-10 (9 KW), SOS-20 (12 KW), SOS-30 (24 KW), and SOS-40 (36 KW). Each model differs in heating power, motor power, pump flow rate, expansion tank capacity, and overall dimensions to suit different production scale requirements.
Is a cooling function available, and how does it work?
Yes, a cooling system is available as an optional but commonly integrated feature. It uses an oil/water heat exchanger or oil/air cooler to enable rapid cool-down after process completion or to assist in temperature control during processes that require cooling phases. The cooling water pipe connection is 1/2 inch across all models.



