Leave Your Message

High-Quality Oil Mold Temperature Controller from China Suppliers | Reliable Factory Supply

,

The Oil Temperature Machine is an advanced mold temperature control system that utilizes heat-conducting oil as its medium. Also known as an oil heater, oil temperature heater, or oil circulation temperature controller, this machine offers precise temperature management with easy operation and a maximum temperature capability of up to 300°C. It is widely utilized across various industries, including hot pressing dies, laminating machines, FRP production, automotive interior components, carbon fiber processing, composite materials, as well as plastic and rubber manufacturing. As a leading supplier and factory for industrial temperature control solutions in China, we are committed to delivering high-quality machinery that meets the demands of modern manufacturing.

,

    Machine Future
    • Return oil temperature display
    • Heating power gear adjustment
    • Start up automatic exhaust
    • PC board self-optimization microprocessor, PID automatic adjustment, simple
    • By-pass pressure relief loop for hot oil
    • The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
    • Imported electrical accessories — WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
    • Perfect safety protection and fault display system
    • Professional personnel needed for repair and maintenance
    ⚙ Optional Features
    • Multi-point temperature control unit can be customized professionally
    • RS485 communication for automatic management
    • PLC control, high reliability, strong anti-interference ability
    • Time switch machine, cooling shut down function
    • Blow back function
    • Explosion-proof design of electric control cabinet and pipeline
    Core Working Principle and System Composition
    Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium.
    1 Operating Cycle
    • High-Temperature Media Circulation: A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
    • High-Temperature Heat Output: The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
    • Oil Return & Temperature Control: After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
    2 Core System Components (Enhanced Design)
    🔧 High-Temperature Heating System
    • Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
    • Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
    • High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
    • High-Temperature Control System — Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
    • Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
    🛡 Safety & Auxiliary Systems (Critical)
    • Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
    • Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
    • Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
    • Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
    Industrial Applications
    Industrial Application 1
    Industrial Application 2
    Industrial Application 3
    Flowchart
    Flowchart
    Specification
    Parameter UNIT MODEL
    SOS-05 SOS-10 SOS-20 SOS-30 SOS-40
    Temp control range ℃ Inlet water temperature +45℃–180℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m³/h 6 6 10 14 16
    Pump head m 18 18 20 18 20
    Power Input KW 6.33 9.75 13.5 26.2 39
    Expansion tank capacity L 20 20 20 30 50
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size (L×W×H) mm 850×325×700 850×325×700 850×325×700 1170×450×950 1500×500×1100
    Products Detail
    HG9A2109
    HG9A2110
    HG9A2117
    Frequently Asked Questions (FAQ)
    Q What is the maximum operating temperature of this thermal oil temperature control unit?
    The unit supports a temperature control range from inlet water temperature +45°C up to 180°C as standard, with high-temperature models capable of reaching up to 350°C or higher depending on the selected thermal oil grade and system configuration.
    Q What type of heat transfer fluid is used, and how should it be selected?
    The system uses thermal conductive oil (thermo oil) as the heat transfer medium. The appropriate grade should be selected based on the maximum operating temperature, required thermal stability, and safety standards. Common grades include L-QB and L-QC. Always consult the manufacturer for the correct specification.
    Q What safety protection features are built into the unit?
    The unit is equipped with comprehensive safety protections including pump reversal detection, oil shortage alarm, overheating protection, overload protection, oil overflow alarm, abnormal heating detection, phase loss/reverse phase protection, and an independent mechanical thermostat over-temperature protection separate from the main control system.
    Q Can the unit be integrated with a factory automation or PLC system?
    Yes. The unit supports optional RS485 communication for automatic management and can be configured with PLC control for high reliability and strong anti-interference capability. This makes it suitable for integration into automated production lines and smart factory environments.
    Q What industries and applications is this thermal oil temperature control unit suitable for?
    This unit is widely used in industries requiring precise high-temperature process control, including plastic molding, rubber vulcanization, chemical reactors, pharmaceutical processing, food production equipment, laminating presses, and other applications involving high-temperature molds, platens, or reactor jackets.
    Q Is cooling functionality available, and how does it work?
    Yes. An optional cooling system is available, using an integrated oil/water heat exchanger or oil/air cooler. This enables rapid cool-down after process completion or assists in temperature control during processes that require cooling phases. The cooling water pipe connection is 1/2" across all standard models (SOS-05 to SOS-40).