Leave Your Message

High-Quality Oil Mold Temperature Controller from China Manufacturers, Suppliers, and Factory for Precision Temperature Control

The Oil Temperature Machine, also known as an oil heater, oil temperature heater, or oil circulation temperature controller, is a specialized mold temperature machine that utilizes heat-conducting oil as its medium. This advanced temperature controller is designed for precise temperature management, reaching a maximum temperature of 300℃, making it ideal for various applications, Manufactured in China, our oil temperature machines are widely used in industries such as hot pressing dies, laminating machines, FRP production, automotive interior parts, carbon fiber applications, composite materials, as well as the plastic and rubber industry. Additionally, they are perfectly suited for use with equipment like clenders, coater rollers, and kneaders, As a leading supplier and factory in the industry, we take pride in delivering high-quality oil temperature solutions that meet the diverse needs of our clients. Choose our Oil Temperature Machine for reliable performance and outstanding results in your manufacturing processes

    Machine Features
    • Return oil temperature display
    • Heating power gear adjustment
    • Start up automatic exhaust
    • PC board self-optimization microprocessor, PID automatic adjustment, simple operation
    • By-pass pressure relief loop for hot oil
    • The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
    • Imported electrical accessories: WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
    • Perfect safety protection and fault display system
    • Professional personnel needed for repair and maintenance

    ⚙ Optional Features
    • Multi-point temperature control unit can be customized professionally
    • RS485 communication for automatic management
    • PLC control, high reliability, strong anti-interference ability
    • Time switch machine, cooling shut down function
    • Blow back function
    • Explosion-proof design of electric control cabinet and pipeline

    Core Working Principle and System Composition

    Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium:

    1 Operating Cycle
    • High-Temperature Media Circulation: A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
    • High-Temperature Heat Output: The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
    • Oil Return & Temperature Control: After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
    2 Core System Components (Enhanced Design)
    🔥 High-Temperature Heating System
    • Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
    • Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
    • High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
    • High-Temperature Control System — Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
    • Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
    🛡️ Safety & Auxiliary Systems (Critical)
    • Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
    • Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
    • Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
    • Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.

    Industrial Applications
    Industrial Application 1
    Industrial Application 2
    Industrial Application 3

    Flowchart
    Flowchart

    Specification
    Parameter UNIT MODEL
    SOS-05 SOS-10 SOS-20 SOS-30 SOS-40
    Temp control range ℃ Inlet water temperature +45℃–180℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m³/h 6 6 10 14 16
    Pump head m 18 18 20 18 20
    Power Input KW 6.33 9.75 13.5 26.2 39
    Expansion tank capacity L 20 20 20 30 50
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size (L×W×H) mm 850×325×700 850×325×700 850×325×700 1170×450×950 1500×500×1100

    Products Detail
    HG9A2109
    HG9A2110
    HG9A2117

    Frequently Asked Questions
    Q What is the maximum operating temperature of this thermal oil temperature control unit?
    The unit supports a temperature control range from inlet water temperature +45°C up to 180°C, with high-temperature heater configurations capable of reaching up to 350°C or higher depending on the thermal oil selected and system design.
    Q What type of heat transfer medium is used, and how is it selected?
    The system uses thermal (conductive) oil as its heat transfer medium. The specific oil grade is selected based on the maximum operating temperature, thermal stability requirements, and safety considerations. Common grades include L-QB and L-QC series thermal oils.
    Q What safety protection features are built into the system?
    The unit is equipped with comprehensive safety protections including pump reversal detection, oil shortage alarm, overheating protection (with independent mechanical thermostat), overload protection, oil overflow alarm, abnormal heating detection, as well as phase loss and reverse phase protection to ensure safe and reliable operation.
    Q Can the unit be integrated into an automated production management system?
    Yes. The unit offers optional RS485 communication support for automatic management and remote monitoring. Additionally, optional PLC control is available for high reliability and strong anti-interference capability, making it suitable for integration into automated production environments.
    Q What models are available and how do I choose the right heating power?
    Five standard models are available: SOS-05 (6 KW), SOS-10 (9 KW), SOS-20 (12 KW), SOS-30 (24 KW), and SOS-40 (36 KW). Selection should be based on your required heating capacity, mold or equipment volume, target temperature, and cycle time. Our technical team can assist with sizing recommendations.
    Q Is explosion-proof design available for hazardous environments?
    Yes. Explosion-proof design for both the electric control cabinet and pipeline is available as an optional feature. This makes the unit suitable for use in flammable, explosive, or chemically hazardous industrial environments where standard electrical enclosures are not sufficient.