Leave Your Message

High-Low Temperature Chamber Manufacturers in China - Reliable Environmental Test Equipment Suppliers & Factory

Introducing our High-Low Temperature Chamber, a state-of-the-art environmental test device proudly manufactured in China. This specialized chamber is designed by leading suppliers in the industry to create accurately controlled high and low temperature conditions within a sealed environment. It serves the critical purpose of testing the performance, reliability, and durability of various products, components, and materials under extreme thermal stress. Whether you are a factory looking to enhance product quality or a business seeking thorough testing solutions, our High-Low Temperature Chamber stands as the ideal choice for meeting your rigorous testing demands

    Main Features and Advantages

    1. Integrated Design
    Combines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
    2. Wide Temperature Range
    Typical temperature ranges span from -80°C to +300°C (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
    - Low-Temperature Type: e.g., -80°C to +200°C
    - High-Temperature Type: e.g., -40°C to +300°C
    - Standard Type: e.g., -25°C to +200°C
    3. High-Precision Temperature Control
    Utilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
    4. Fully Enclosed Circulation
    The medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
    5. High Efficiency and Speed
    Powerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
    6. Versatility
    A single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.

    Core Application Areas

    1. Chemistry and Pharmaceuticals
    - Temperature control for reactors and glass reaction vessels.
    - Temperature management during synthesis, crystallization, extraction, and distillation processes.
    - Pilot-scale and industrial-scale production.
    2. Biotechnology and Laboratories
    - Temperature regulation for fermenters and bioreactors.
    - Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
    - Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
    3. Materials Testing and New Energy
    - Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
    - Testing of semiconductor components and chips.
    - Research and performance testing of new materials (e.g., polymer materials).
    4. Automotive and Aerospace
    - Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
    - Testing of lubricants and fuels.
    5. Petrochemical Industry
    - Temperature control for analytical instruments such as viscometers and rheometers.

    Selection Guide (Key Parameters to Consider When Purchasing)

    1. Temperature Range
    Select based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
    2. Temperature Control Accuracy and Stability
    Higher precision requirements typically correspond to higher equipment costs.
    3. Heating and Cooling Capacity
    The power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
    4. Pump Flow Rate and Head
    - Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
    - Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
    5. Heat Transfer Fluid
    - Silicone Oil: The most commonly used option, with a wide temperature range (-40°C to 200°C) and stable performance.
    - Water/Ethylene Glycol Solution: Suitable for temperatures above 0°C, environmentally friendly and clean.
    - Special High-Temperature Oil: For use above 300°C.
    - Special Low-Temperature Fluid: For use below -80°C.
    6. Internal Circulation vs. External Circulation
    - Internal Circulation: Circulates the fluid within the device itself, primarily for maintaining the temperature of the internal bath.
    - External Circulation: Connects to external equipment for fluid circulation. This is the main function. Ensure compatibility of external circulation interface dimensions and materials during selection.
    7. Safety and Protection Features
    Over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
    8. Programming Capabilities
    Determine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.

    Typical Industrial Applications

    16
    15
    14

    Flowchart

    High-and-Low-Temperature-Series

    specification

    Parameter UNIT MODEL
    SOS-05 SOS-10 SOS-20 SOS-30 SOS-40

    Products Detail

    HG9A2109
    HG9A2110
    HG9A2117

    Frequently Asked Questions (FAQ)

    Q: What typical temperature range do these integrated systems cover?
    Typical temperature ranges span from -80°C to +300°C (or higher), depending on the specific system configuration, such as Low-Temperature, High-Temperature, or Standard types.
    Q: How accurate is the temperature control mechanism?
    The systems utilize PID intelligent control, achieving temperature stability reaching ±0.1°C or even ±0.01°C for high-precision experimentation.
    Q: What are the benefits of a fully enclosed circulation system?
    The fully enclosed circulation prevents fluid contact with air, which significantly reduces oxidation, evaporation, and contamination while ensuring high operational safety and fluid savings.
    Q: Which heat transfer fluid should I choose for my application?
    Selection depends on operational temperature: Silicone Oil (-40°C to 200°C), Water/Ethylene Glycol (above 0°C), Special High-Temperature Oil (above 300°C), or Special Low-Temperature Fluid (below -80°C).
    Q: What key industries utilize these temperature control systems?
    Primary industries include Chemistry & Pharmaceuticals, Biotechnology & Laboratories, Materials Testing & New Energy, Automotive & Aerospace, and the Petrochemical Industry.