0102030405
High-Low Temperature Chamber from China Suppliers | Reliable Testing Solutions from a Leading Factory
Main Features and Advantages
-
🔧
1. Integrated DesignCombines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
-
🌡️
2. Wide Temperature RangeTypical temperature ranges span from -80°C to +300°C (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
- Low-Temperature Type: e.g., -80°C to +200°C
- High-Temperature Type: e.g., -40°C to +300°C
- Standard Type: e.g., -25°C to +200°C
-
🎯
3. High-Precision Temperature ControlUtilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
-
🔒
4. Fully Enclosed CirculationThe medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
-
⚡
5. High Efficiency and SpeedPowerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
-
🔄
6. VersatilityA single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
⚗️ Chemistry and Pharmaceuticals
- Temperature control for reactors and glass reaction vessels.
- Temperature management during synthesis, crystallization, extraction, and distillation processes.
- Pilot-scale and industrial-scale production.
🧬 Biotechnology and Laboratories
- Temperature regulation for fermenters and bioreactors.
- Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
- Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
🔬 Materials Testing and New Energy
- Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
- Testing of semiconductor components and chips.
- Research and performance testing of new materials (e.g., polymer materials).
🚗 Automotive and Aerospace
- Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
- Testing of lubricants and fuels.
🏭 Petrochemical Industry
- Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide — Key Parameters to Consider When Purchasing
1 Temperature Range
Select based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
2 Temperature Control Accuracy and Stability
Higher precision requirements typically correspond to higher equipment costs.
3 Heating and Cooling Capacity
The power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
4 Pump Flow Rate and Head
- Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
- Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
5 Heat Transfer Fluid
- Silicone Oil: The most commonly used option, with a wide temperature range (-40°C to 200°C) and stable performance.
- Water/Ethylene Glycol Solution: Suitable for temperatures above 0°C, environmentally friendly and clean.
- Special High-Temperature Oil: For use above 300°C.
- Special Low-Temperature Fluid: For use below -80°C.
6 Internal vs. External Circulation
- Internal Circulation: Circulates the fluid within the device itself, primarily for maintaining the temperature of the internal bath.
- External Circulation: Connects to external equipment for fluid circulation. Ensure compatibility of external circulation interface dimensions and materials during selection.
7 Safety and Protection Features
Over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
8 Programming Capabilities
Determine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
Products Detail
Frequently Asked Questions (FAQ)
Q What is the typical temperature range of a dynamic temperature control system?
Dynamic temperature control systems typically cover a wide range from -80°C to +300°C, depending on the model and heat transfer fluid selected. Low-temperature models may reach as low as -80°C, while high-temperature models can exceed 300°C with special thermal fluids.
Q What heat transfer fluid should I choose for my application?
The choice depends on your temperature range and application requirements. Silicone oil is the most versatile option (-40°C to 200°C). Water/ethylene glycol solutions are suitable for above 0°C applications. Special high-temperature oils are used above 300°C, and dedicated low-temperature fluids are required below -80°C.
Q What is the difference between internal and external circulation modes?
Internal circulation maintains the temperature of the fluid within the unit's own bath. External circulation connects to outside equipment (such as reactors or test chambers) and pumps the temperature-controlled fluid through external piping — this is the primary working mode for most industrial and laboratory applications.
Q How precise is the temperature control, and is it suitable for sensitive laboratory experiments?
Yes. These systems use PID intelligent control algorithms to achieve temperature stability of ±0.1°C or even ±0.01°C, making them well-suited for demanding laboratory experiments such as chemical synthesis, enzymatic reactions, and cell culture.
Q What safety protection features are included in these systems?
Standard safety features include over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions. These ensure safe and reliable operation even during long-duration automated processes.
Q Can the system be programmed for automated heating and cooling cycles?
Yes. Models with multi-segment programming capabilities allow users to set automated temperature profiles including heating, holding, and cooling stages. This is especially useful for battery cycling tests, material aging studies, and other processes that require repeatable thermal cycling.