0102030405
High and Low Temperature Chamber - Reliable Testing Solutions from Trusted China Suppliers and Factory
Main Features and Advantages
-
🔧1. Integrated Design Combines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
-
🌡️2. Wide Temperature Range Typical temperature ranges span from -80°C to +300°C (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
- Low-Temperature Type: e.g., -80°C to +200°C
- High-Temperature Type: e.g., -40°C to +300°C
- Standard Type: e.g., -25°C to +200°C
-
🎯3. High-Precision Temperature Control Utilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
-
🔒4. Fully Enclosed Circulation The medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
-
⚡5. High Efficiency and Speed Powerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
-
🔄6. Versatility A single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
⚗️1. Chemistry and Pharmaceuticals
- Temperature control for reactors and glass reaction vessels.
- Temperature management during synthesis, crystallization, extraction, and distillation processes.
- Pilot-scale and industrial-scale production.
🧬2. Biotechnology and Laboratories
- Temperature regulation for fermenters and bioreactors.
- Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
- Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
🔋3. Materials Testing and New Energy
- Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
- Testing of semiconductor components and chips.
- Research and performance testing of new materials (e.g., polymer materials).
🚗4. Automotive and Aerospace
- Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
- Testing of lubricants and fuels.
🏭5. Petrochemical Industry
- Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide — Key Parameters to Consider When Purchasing
🌡️1. Temperature Range
Select based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
🎯2. Temperature Control Accuracy and Stability
Higher precision requirements typically correspond to higher equipment costs.
⚡3. Heating and Cooling Capacity
The power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
💧4. Pump Flow Rate and Head
- Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
- Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
🧪5. Heat Transfer Fluid
- Silicone Oil: Most commonly used, wide range (-40°C to 200°C), stable performance.
- Water/Ethylene Glycol Solution: Suitable for above 0°C, environmentally friendly.
- Special High-Temperature Oil: For use above 300°C.
- Special Low-Temperature Fluid: For use below -80°C.
🔄6. Internal vs. External Circulation
- Internal Circulation: Circulates fluid within the device itself, primarily for maintaining internal bath temperature.
- External Circulation: Connects to external equipment. Ensure compatibility of interface dimensions and materials.
🛡️7. Safety and Protection Features
Over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
📋8. Programming Capabilities
Determine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
Products Detail
Frequently Asked Questions (FAQ)
❓What is the typical temperature range of a Dynamic Temperature Control System (TCU)?
Most TCU models cover a temperature range from -80°C to +300°C, though the exact range depends on the specific model and heat transfer fluid used. Low-temperature types can reach as low as -80°C, while high-temperature types can go up to +300°C or beyond.
❓What heat transfer fluids are compatible with TCU systems?
Common heat transfer fluids include silicone oil (suitable for -40°C to 200°C), water/ethylene glycol solutions (for temperatures above 0°C), special high-temperature oils (for above 300°C), and special low-temperature fluids (for below -80°C). The choice depends on your required temperature range and process requirements.
❓What level of temperature control accuracy can a TCU achieve?
TCU systems utilize PID intelligent control algorithms, achieving temperature stability of ±0.1°C in standard configurations and as precise as ±0.01°C in high-accuracy models, making them suitable for demanding laboratory and industrial processes.
❓What is the difference between internal and external circulation modes?
Internal circulation keeps the heat transfer fluid circulating within the TCU unit itself, primarily used to maintain the temperature of the internal bath. External circulation connects the TCU to external equipment (such as reactors or test chambers) via hoses or piping, which is the primary function for most industrial and laboratory applications.
❓What safety protection features are built into TCU systems?
TCU systems are typically equipped with comprehensive safety features including over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions to ensure safe and reliable continuous operation.
❓Can a TCU be used for automated temperature cycling programs?
Yes. Many TCU models support multi-segment temperature programming, allowing users to set automated sequences of heating, holding, and cooling stages. This is particularly useful for battery testing, material aging tests, and other cyclic thermal processes that require precise, repeatable temperature profiles.

