0102030405
High and Low Temperature Chamber - Reliable Testing Solutions from China Suppliers and Factory
Main Features and Advantages
1. Integrated Design
Combines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
2. Wide Temperature Range
Typical temperature ranges span from -80°C to +300°C** (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
Low-Temperature Type: e.g., -80°C to +200°C
High-Temperature Type: e.g., -40°C to +300°C
Standard Type: e.g., -25°C to +200°C
3. High-Precision Temperature Control
Utilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
4. Fully Enclosed Circulation
The medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
5. High Efficiency and Speed
Powerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
6. Versatility
A single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
1. Chemistry and Pharmaceuticals
Temperature control for reactors and glass reaction vessels.
Temperature management during synthesis, crystallization, extraction, and distillation processes.
Pilot-scale and industrial-scale production.
2. Biotechnology and Laboratories
Temperature regulation for fermenters and bioreactors.
Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
3. Materials Testing and New Energy
Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
Testing of semiconductor components and chips.
Research and performance testing of new materials (e.g., polymer materials).
4. Automotive and Aerospace
Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
Testing of lubricants and fuels.
5. Petrochemical Industry
Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide (Key Parameters to Consider When Purchasing)
1. Temperature Range
Select based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
2. Temperature Control Accuracy and Stability
Higher precision requirements typically correspond to higher equipment costs.
3. Heating and Cooling Capacity
The power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
4. Pump Flow Rate and Head
Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
5. Heat Transfer Fluid
Silicone Oil: The most commonly used option, with a wide temperature range (-40°C to 200°C) and stable performance.
Water/Ethylene Glycol Solution: Suitable for temperatures above 0°C, environmentally friendly and clean.
Special High-Temperature Oil: For use above 300°C.
Special Low-Temperature Fluid: For use below -80°C.
6. Internal Circulation vs. External Circulation
Internal Circulation: Circulates the fluid within the device itself, primarily for maintaining the temperature of the internal bath.
External Circulation: Connects to external equipment for fluid circulation. This is the main function. Ensure compatibility of external circulation interface dimensions and materials during selection.
7. Safety and Protection Features
Over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
8. Programming Capabilities
Determine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
Products Detail
Frequently Asked Questions (FAQ)
What is the typical temperature range of these integrated systems?
The temperature ranges typically span from -80°C to +300°C (or higher), depending on the specific model and the heat transfer fluid used. We offer Low-Temperature, High-Temperature, and Standard models to suit various application requirements.
How does the fully enclosed circulation system improve safety?
By circulating the thermal medium in a completely sealed system, the fluid avoids contact with ambient air. This significantly reduces fluid oxidation, evaporation, and contamination, which ensures high operational safety and extends the service life of the fluid.
What type of heat transfer fluid should I select for my application?
Silicone oil is the most common choice due to its wide range (-40°C to 200°C) and stability. A water/ethylene glycol solution is suitable for temperatures above 0°C. For extreme conditions, choose specialized high-temperature oil (above 300°C) or low-temperature fluid (below -80°C).
What is the temperature control accuracy of these units?
Our systems utilize intelligent PID control. The temperature stability can reach up to ±0.1°C or even ±0.01°C depending on the model, meeting the strict requirements of precise laboratory experiments and industrial processes.
Can these systems be integrated into automated processes?
Yes. Models equipped with programming capabilities support multi-segment temperature programming. This allows you to automate cyclic testing processes involving heating, holding, and cooling stages.
How do I calculate the required heating and cooling capacity?
The required capacity depends on the volume and material of your reactor vessel, the properties of the reaction medium, and your desired temperature ramp rate. Our team can assist you with precise calculations based on these parameters.