0102030405
High and Low Temperature Chamber - Reliable Testing Equipment from China Suppliers and Factory
Main Features and Advantages
-
1
Integrated Design Combines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
-
2
Wide Temperature Range Typical temperature ranges span from -80°C to +300°C (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
- Low-Temperature Type: e.g., -80°C to +200°C
- High-Temperature Type: e.g., -40°C to +300°C
- Standard Type: e.g., -25°C to +200°C
-
3
High-Precision Temperature Control Utilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
-
4
Fully Enclosed Circulation The medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
-
5
High Efficiency and Speed Powerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
-
6
Versatility A single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
🧪 Chemistry and Pharmaceuticals
- Temperature control for reactors and glass reaction vessels.
- Temperature management during synthesis, crystallization, extraction, and distillation processes.
- Pilot-scale and industrial-scale production.
🔬 Biotechnology and Laboratories
- Temperature regulation for fermenters and bioreactors.
- Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
- Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
⚡ Materials Testing and New Energy
- Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
- Testing of semiconductor components and chips.
- Research and performance testing of new materials (e.g., polymer materials).
🚗 Automotive and Aerospace
- Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
- Testing of lubricants and fuels.
🏭 Petrochemical Industry
- Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide — Key Parameters to Consider When Purchasing
1 Temperature Range
Select based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
2 Temperature Control Accuracy and Stability
Higher precision requirements typically correspond to higher equipment costs.
3 Heating and Cooling Capacity
The power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
4 Pump Flow Rate and Head
- Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
- Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
5 Heat Transfer Fluid
- Silicone Oil: Most commonly used, wide range (-40°C to 200°C), stable performance.
- Water/Ethylene Glycol: Suitable above 0°C, environmentally friendly and clean.
- Special High-Temperature Oil: For use above 300°C.
- Special Low-Temperature Fluid: For use below -80°C.
6 Internal vs. External Circulation
- Internal Circulation: Circulates fluid within the device itself, primarily for maintaining the internal bath temperature.
- External Circulation: Connects to external equipment for fluid circulation. Ensure compatibility of interface dimensions and materials.
7 Safety and Protection Features
Over-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
8 Programming Capabilities
Determine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the typical temperature range of a dynamic temperature control system (TCU)?
Most dynamic TCU systems cover a temperature range from -80°C to +300°C, though specific ranges vary by model. Low-temperature types typically operate from -80°C to +200°C, high-temperature types from -40°C to +300°C, and standard types from -25°C to +200°C. Always confirm the required temperature range before selecting a model, leaving a suitable safety margin.
Q
What heat transfer fluids are compatible with TCU systems?
The most common options include: Silicone Oil (wide temperature range, -40°C to 200°C, chemically stable); Water/Ethylene Glycol solution (suitable for above 0°C, eco-friendly); Special high-temperature oil (for applications above 300°C); and Special low-temperature fluid (for applications below -80°C). The choice depends on your required temperature range and process requirements.
Q
What is the difference between internal circulation and external circulation in a TCU?
Internal circulation keeps the heat transfer fluid circulating within the unit's own bath, primarily used to maintain a stable temperature inside the device. External circulation pumps the fluid out to connected external equipment (such as reactors, test chambers, or other instruments) for precise temperature control. For most industrial and laboratory applications, external circulation is the primary function. Ensure the external circulation interfaces are compatible with your equipment.
Q
How do I select the right heating and cooling capacity for my application?
The required heating and cooling capacity depends on several factors: the volume and thermal mass of the reactor or equipment being controlled, the desired temperature ramp rate (how quickly you need to reach the target temperature), and any heat generated or absorbed by the process itself. It is recommended to consult with the manufacturer and provide these parameters to ensure the selected model meets your process demands without being over- or under-powered.
Q
What safety protection features should a TCU include?
A well-designed TCU should include multiple layers of protection: over-temperature protection to prevent overheating, low-liquid-level protection to avoid dry-run damage to the pump and heater, over-current and leakage protection for electrical safety, and self-diagnostic functions that alert operators to faults in real time. These features are critical for safe, unattended long-term operation in laboratory and industrial environments.
Q
Can a TCU be used for automated temperature cycling programs?
Yes. Most advanced TCU models support multi-segment temperature programming, allowing users to pre-set complex sequences of heating, holding, and cooling stages. This is especially useful for battery cycle testing, material aging studies, and pharmaceutical process validation, where precise and repeatable temperature profiles are essential. Check the model's programming capabilities and number of programmable segments before purchase.