0102030405
High and Low Temperature Chamber - Reliable Testing Equipment from China Suppliers and Factory
Main Features and Advantages
-
Integrated DesignCombines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
-
Wide Temperature RangeTypical temperature ranges span from -80°C to +300°C** (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
- Low-Temperature Type: e.g., -80°C to +200°C
- High-Temperature Type: e.g., -40°C to +300°C
- Standard Type: e.g., -25°C to +200°C
-
High-Precision Temperature ControlUtilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
-
Fully Enclosed CirculationThe medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
-
High Efficiency and SpeedPowerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
-
VersatilityA single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
1. Chemistry and Pharmaceuticals
- Temperature control for reactors and glass reaction vessels.
- Temperature management during synthesis, crystallization, extraction, and distillation processes.
- Pilot-scale and industrial-scale production.
2. Biotechnology and Laboratories
- Temperature regulation for fermenters and bioreactors.
- Applications in cell culture, enzymatic reactions, and as a thermal source for PCR instruments.
- Cooling/heating support for rotary evaporators, cold traps, and freeze dryers.
3. Materials Testing and New Energy
- Environmental simulation for battery testing (e.g., lithium-ion batteries, fuel cells), including high-low temperature cycling tests.
- Testing of semiconductor components and chips.
- Research and performance testing of new materials (e.g., polymer materials).
4. Automotive and Aerospace
- Environmental simulation testing for automotive components (e.g., motors, battery packs, sensors).
- Testing of lubricants and fuels.
5. Petrochemical Industry
- Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide (Key Parameters to Consider When Purchasing)
-
1. Temperature RangeSelect based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
-
2. Temperature Control Accuracy and StabilityHigher precision requirements typically correspond to higher equipment costs.
-
3. Heating and Cooling CapacityThe power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
-
4. Pump Flow Rate and Head
- Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
- Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
-
5. Heat Transfer Fluid
- Silicone Oil: The most commonly used option, with a wide temperature range (-40°C to 200°C) and stable performance.
- Water/Ethylene Glycol Solution: Suitable for temperatures above 0°C, environmentally friendly and clean.
- Special High-Temperature Oil: For use above 300°C.
- Special Low-Temperature Fluid: For use below -80°C.
-
6. Internal Circulation vs. External Circulation
- Internal Circulation: Circulates the fluid within the device itself, primarily for maintaining the temperature of the internal bath.
- External Circulation: Connects to external equipment for fluid circulation. This is the main function. Ensure compatibility of external circulation interface dimensions and materials during selection.
-
7. Safety and Protection FeaturesOver-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
-
8. Programming CapabilitiesDetermine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
|---|---|---|---|---|---|---|
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
| - | - | - | - | - | - | - |
Products Detail
Frequently Asked Questions
What is the typical temperature range for these dynamic temperature control systems?
The typical temperature range spans from -80°C to +300°C (or higher). The exact range depends on the specific model chosen (low-temperature, high-temperature, or standard type) and the heat transfer fluid used.
How does the fully enclosed circulation system benefit my process?
A fully enclosed circulation system ensures the thermal fluid does not contact the air. This prevents fluid oxidation, evaporation, and contamination, which increases safety, extends fluid life, and saves operational costs.
Which heat transfer fluid should I select for my application?
Silicone oil is recommended for a wide range of -40°C to 200°C. For clean, eco-friendly processes above 0°C, a water/ethylene glycol solution is ideal. For extreme temperatures, specialized low-temperature fluids (below -80°C) or high-temperature oils (above 300°C) should be used.
What is the difference between internal and external circulation?
Internal circulation cycles the fluid within the device to maintain the temperature of its own bath. External circulation, which is the system's primary function, pumps the fluid out to external equipment (like reactors) for direct heat exchange.
Can these units support automated temperature profiling?
Yes, units equipped with programming capabilities support multi-segment temperature programming. This allows you to set automated cycles for heating, holding, and cooling stages during testing or synthesis.