Main Features and Advantages
-
🔧
1. Integrated DesignCombines compressor refrigeration, electric heating, circulation pump, expansion tank, and control system into a single unit, saving space and simplifying installation.
-
🌡️
2. Wide Temperature RangeTypical temperature ranges span from -80°C to +300°C (or even higher), covering the majority of experimental and industrial needs. Specific ranges depend on the model and heat transfer fluid.
- Low-Temperature Type: e.g., -80°C to +200°C
- High-Temperature Type: e.g., -40°C to +300°C
- Standard Type: e.g., -25°C to +200°C
-
🎯
3. High-Precision Temperature ControlUtilizes PID intelligent control, with temperature stability reaching ±0.1°C or even ±0.01°C, meeting the requirements of precise experiments.
-
🔒
4. Fully Enclosed CirculationThe medium circulates in a sealed system, avoiding contact with air, which reduces oxidation, evaporation, and contamination, ensuring high safety and saving fluid.
-
⚡
5. High Efficiency and SpeedPowerful heating and cooling capacities enable rapid achievement of target temperatures, shortening process waiting times.
-
🔄
6. VersatilityA single unit can replace traditional setups such as "oil bath + low-temperature coolant circulation pump," enabling automated and continuous temperature ramp processes.
Core Application Areas
⚗️
1. Chemistry and Pharmaceuticals
- Temperature control for reactors and glass reaction vessels.
- Temperature management during synthesis, crystallization, extraction, and distillation.
- Pilot-scale and industrial-scale production.
🧬
2. Biotechnology and Laboratories
- Temperature regulation for fermenters and bioreactors.
- Cell culture, enzymatic reactions, and thermal source for PCR instruments.
- Cooling/heating for rotary evaporators, cold traps, and freeze dryers.
🔋
3. Materials Testing and New Energy
- Environmental simulation for battery testing (lithium-ion, fuel cells), high-low temperature cycling.
- Testing of semiconductor components and chips.
- Research and testing of new materials (e.g., polymer materials).
🚗
4. Automotive and Aerospace
- Environmental simulation testing for automotive components (motors, battery packs, sensors).
- Testing of lubricants and fuels.
🏭
5. Petrochemical Industry
- Temperature control for analytical instruments such as viscometers and rheometers.
Selection Guide — Key Parameters to Consider When Purchasing
-
🌡️ 1. Temperature RangeSelect based on the maximum and minimum temperature requirements of your experiment or process, with some allowance for margin.
-
🎯 2. Temperature Control Accuracy and StabilityHigher precision requirements typically correspond to higher equipment costs.
-
⚡ 3. Heating and Cooling CapacityThe power rating determines the rate of heating and cooling. This should be calculated based on the volume and material of the reactor, as well as the desired temperature ramp rate.
-
💧 4. Pump Flow Rate and Head
- Flow Rate (L/min): Determines the circulation speed and affects heat exchange efficiency.
- Head (m): Determines the ability to overcome pipeline resistance, especially when the reactor is elevated or the piping is long.
-
🧪 5. Heat Transfer Fluid
- Silicone Oil: Most commonly used, wide temperature range (-40°C to 200°C), stable performance.
- Water/Ethylene Glycol Solution: Suitable for temperatures above 0°C, environmentally friendly and clean.
- Special High-Temperature Oil: For use above 300°C.
- Special Low-Temperature Fluid: For use below -80°C.
-
🔄 6. Internal Circulation vs. External Circulation
- Internal Circulation: Circulates the fluid within the device itself, primarily for maintaining the temperature of the internal bath.
- External Circulation: Connects to external equipment for fluid circulation. Ensure compatibility of external circulation interface dimensions and materials during selection.
-
🛡️ 7. Safety and Protection FeaturesOver-temperature protection, low-liquid-level protection, over-current protection, leakage protection, and self-diagnostic functions.
-
📋 8. Programming CapabilitiesDetermine whether multi-segment temperature programming is needed for automated cyclic testing involving heating, holding, and cooling stages.
Typical Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
Products Detail
Frequently Asked Questions (FAQ)
-
❓ What is the typical temperature range of a dynamic temperature control system?Most dynamic temperature control systems (TCUs) offer a working range from -80°C to +300°C, though the exact range varies by model and the heat transfer fluid used. Low-temperature models typically cover -80°C to +200°C, while high-temperature models can reach up to +300°C or beyond.
-
❓ What heat transfer fluid should I use for my application?The choice depends on your temperature range: Silicone oil is ideal for -40°C to +200°C general use; water/ethylene glycol solutions work well above 0°C for clean and eco-friendly applications; special high-temperature oil is required above 300°C; and special low-temperature fluids are needed below -80°C.
-
❓ What is the difference between internal and external circulation modes?Internal circulation keeps the fluid cycling within the unit's own bath — ideal for maintaining the temperature of the internal reservoir. External circulation pumps the fluid out to connected external equipment such as reactors, autoclaves, or test chambers, which is the primary function for most industrial and laboratory applications.
-
❓ How precise is the temperature control, and is it suitable for sensitive experiments?Yes. These systems use PID intelligent control algorithms, achieving temperature stability of ±0.1°C in standard configurations and as fine as ±0.01°C in high-precision models. This level of accuracy is well-suited for demanding applications such as pharmaceutical synthesis, enzymatic reactions, and semiconductor testing.
-
❓ What safety features are included in the system?The system incorporates multiple protection mechanisms including over-temperature protection, low-liquid-level alarm, over-current protection, leakage protection, and a self-diagnostic function — ensuring safe and reliable operation in both laboratory and industrial environments.
-
❓ Can the system run automated temperature cycling programs?Yes. Models with multi-segment programming capability allow users to pre-set complex temperature profiles involving sequential heating, holding, and cooling stages. This is especially useful for automated cyclic testing in battery research, materials testing, and pharmaceutical process development.