Leave Your Message

Electric Thermal Oil Heater - High-Temperature Industrial Heating System from China Suppliers and Factory

Introducing our Electric Thermal Oil Heater, a cutting-edge industrial heating system designed for superior thermal efficiency. This advanced heater utilizes electric heating elements to elevate the temperature of a specialized heat transfer fluid, known as thermal oil, within a sealed and pressurized loop. As a leading manufacturer in China, our factory produces heaters that circulate heated oil through a pump, delivering precise, high-temperature thermal energy to various process equipment. Ideal for applications requiring temperatures ranging from 150°C to over 350°C, our Electric Thermal Oil Heater provides a clean and controllable heat source without the emissions associated with traditional combustion-based systems. Trust our factory to supply you with a reliable and efficient heating solution tailored to your industrial needs.

    Part I: Working Principle

    The system operates as a closed-loop circuit:
    STEP 01
    Heating

    Electrical energy is converted into thermal energy via electric heating elements, which directly transfer heat to the organic heat transfer fluid (thermal oil).

    STEP 02
    Circulation

    The high-temperature thermal oil is driven by a circulating pump and flows through the piping system.

    STEP 03
    Heat Release

    The high-temperature thermal oil passes through the user's heat-consuming equipment (e.g., reaction kettles, heated platens, drying ovens), transferring its heat to the process medium.

    STEP 04
    Return

    The cooled thermal oil returns to the heater to be reheated, thus beginning the next cycle.

    Part II: Core System Components

    1. Heating System
    Electric Heating Elements
    The core heating components, typically made of stainless steel or high-temperature resistant alloy, directly immersed in the oil.
    Electrical Control Cabinet
    Contains circuit breakers, contactors, SCR power regulators (for power modulation), protective devices, etc., for controlling and distributing electrical power.
    2. Thermal Oil Circulation System
    Circulating Pump
    Provides the motive force to ensure forced circulation of the thermal oil throughout the system.
    Expansion Tank
    Accommodates the volumetric expansion of the thermal oil when heated and isolates it from air to prevent oxidation.
    Storage Tank
    Used for storing the thermal oil during system maintenance.
    3. Control and Safety Protection Systems
    (1) Temperature Control
    Utilizes PID intelligent temperature controllers for precise control of the outlet oil temperature.
    (2) Multiple Safety Protections
    • Over temperature Protection: Monitors oil temperature and automatically cuts power if it exceeds the set value.
    • Low Oil Level Protection: Prevents dry-firing of the heating elements.
    • Flow/Pressure Protection: Monitors the operating status of the circulating pump; alarms and stops heating in case of insufficient flow.
    • Overpressure Protection: Relieves pressure via a safety valve.
    • Electrical Protection: Over current, short circuit, phase loss, and leakage protection.

    Part III: Main Advantages

    1. Environmentally Friendly & Clean

    Zero emissions, no combustion exhaust, smoke, dust, or noise pollution. Suitable for areas with strict environmental regulations and for indoor installation within workshops.

    2. High Thermal Efficiency

    Direct conversion of electrical energy to thermal energy results in a high inherent equipment efficiency, often exceeding 95%.

    3. Precise Temperature Control

    Advanced PID control enables temperature regulation accuracy within ±1°C, allowing for smooth heating and stable temperature holding.

    4. Stable Operation

    Fully automatic control, simple operation, and relatively low maintenance workload.

    5. Simple Installation

    No need for a boiler room, chimney, or fuel storage facilities. Requires a small footprint and has low infrastructure costs.

    6. Good Safety Profile

    Operates at atmospheric or low pressure, eliminating explosion risks (compared to steam boilers).

    Part V: Typical Application Industries

    Chemical Industry

    Heating for reaction kettles, distillation, concentration, polymerization.

    Plastics & Rubber Industry

    Heating for hot pressing, extrusion, vulcanization molding.

    Textile & Dyeing Industry

    Heat supply for heat setting machines, dryers, dyeing machines.

    Food Industry

    Heat supply for ovens, fryers, sterilizers.

    Building Materials Industry

    Asphalt heating, concrete curing.

    Wood Processing

    Timber drying, hot platen heating.

    Specification

    Parameter UNIT MODEL
    YWDR0.12 YWDR0.18 YWDR0.24 YWDR0.4 YWDR0.6 YWDR0.8 YWDR1.2
    Temp control range ℃ Inlet water temperature +45℃-300℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating
    Heating power KW 120 180 240 400 600 800 1200
    Motor power KW 5.5 7.5 7.5 11 22 22 37
    Pump flow m3/h 25 30 30 45 100 100 160
    Pump head m 35 48 48 40 55 55 50
    Power Input KW 125.5 187.5 247.5 411 622 822 1237
    Circulating oil pipe Inch 2"(DN50) 2.5"(DN65) 2.5"(DN65) 3"(DN80) 4"(DN100) 4"(DN125) 6"(DN150)
    Distribution Cabinet Installation Formats integration integration integration Single Single Single Single
    Size(LxWxH) mm 2400*1150*1800 2400*1200*2000 2400*1250*2000 2900*1500*2600 2900*1900*2900 3000*2000*3100 2600*1900*2900
    3000*1900*1600

    Flowchart

    flow

    Products Detail

    Electric Heating Thermal Oil Boiler (1)
    Electric Heating Thermal Oil Boiler (2)
    Electric Heating Thermal Oil Boiler (3)

    Frequently Asked Questions (FAQ)

    Q1 What is the maximum operating temperature range of the electric thermal oil heater?

    The system provides precise temperature control ranging from inlet water temperature +45℃ up to 300℃, managed seamlessly by intelligent PID controllers.

    Q2 How accurate is the temperature regulation?

    With advanced PID intelligent temperature control systems, the temperature regulation accuracy is maintained within ±1°C, providing stable temperature holding for sensitive thermal processes.

    Q3 What safety protection systems are included in the unit?

    The unit includes multi-tier protection: over-temperature cutoff, low oil level dry-firing prevention, pump flow/pressure monitoring, safety valve overpressure relief, and complete electrical fault safeguards (overcurrent, phase loss, short circuit, and leakage).

    Q4 Why choose an electric thermal oil boiler over a traditional steam boiler?

    Electric thermal oil systems operate under atmospheric or low pressures, eliminating explosion risks. Additionally, they produce zero emissions, operate at over 95% thermal efficiency, and require no dedicated boiler room or chimney infrastructure.

    Q5 What heating capacities (power ranges) are available?

    Standard models offer heating powers ranging from 120 KW (model YWDR0.12) up to 1200 KW (model YWDR1.2), accommodating diverse industrial scale applications.

    Q6 Which industries commonly adopt this electric heating system?

    It is widely used across chemical reaction kettles, plastics & rubber vulcanization/extrusion, textile heat setting, food processing ovens/fryers, building materials (asphalt/concrete curing), and timber drying processes.