Leave Your Message

Electric Thermal Oil Heater - High-Temperature Heating Solutions from China Suppliers and Factory

Introducing our Electric Thermal Oil Heater, an advanced industrial heating solution designed by leading China suppliers. This innovative system employs electric heating elements to elevate the temperature of specialized heat transfer fluids—thermal oils—within a sealed, pressurized loop. Our heaters efficiently circulate this heated oil through a pump, delivering precise, high-temperature thermal energy essential for various process equipment. Operating effectively in a range from 150°C to over 350°C, our Electric Thermal Oil Heater provides a clean and controllable heat source, free from the emissions commonly associated with combustion-based heating systems. Partner with our factory for a reliable and efficient thermal energy solution tailored to your industrial needs

    Part I: Working Principle
    The system operates as a closed-loop circuit:
    • 1 Heating: Electrical energy is converted into thermal energy via electric heating elements, which directly transfer heat to the organic heat transfer fluid (thermal oil).
    • 2 Circulation: The high-temperature thermal oil is driven by a circulating pump and flows through the piping system.
    • 3 Heat Release: The high-temperature thermal oil passes through the user's heat-consuming equipment (e.g., reaction kettles, heated platens, drying ovens), transferring its heat to the process medium.
    • 4 Return: The cooled thermal oil returns to the heater to be reheated, thus beginning the next cycle.
    Part II: Core System Components
    1. Heating System
    • Electric Heating Elements: The core heating components, typically made of stainless steel or high-temperature resistant alloy, directly immersed in the oil.
    • Electrical Control Cabinet: Contains circuit breakers, contactors, SCR power regulators (for power modulation), protective devices, etc., for controlling and distributing electrical power.
    2. Thermal Oil Circulation System
    • Circulating Pump: Provides the motive force to ensure forced circulation of the thermal oil throughout the system.
    • Expansion Tank: Accommodates the volumetric expansion of the thermal oil when heated and isolates it from air to prevent oxidation.
    • Storage Tank: Used for storing the thermal oil during system maintenance.
    3. Control and Safety Protection Systems
    • Temperature Control: Utilizes PID intelligent temperature controllers for precise control of the outlet oil temperature.
    • Multiple Safety Protections:
      • Over Temperature Protection: Monitors oil temperature and automatically cuts power if it exceeds the set value.
      • Low Oil Level Protection: Prevents dry-firing of the heating elements.
      • Flow / Pressure Protection: Monitors the operating status of the circulating pump; alarms and stops heating in case of insufficient flow.
      • Overpressure Protection: Relieves pressure via a safety valve.
      • Electrical Protection: Over current, short circuit, phase loss, and leakage protection.
    Part III: Main Advantages
    🌿
    Environmentally Friendly & Clean
    Zero emissions, no combustion exhaust, smoke, dust, or noise pollution. Suitable for strict environmental regulations and indoor workshop installation.
    ⚡
    High Thermal Efficiency
    Direct conversion of electrical energy to thermal energy results in high equipment efficiency, often exceeding 95%.
    🎯
    Precise Temperature Control
    Advanced PID control enables temperature regulation accuracy within ±1°C, allowing smooth heating and stable temperature holding.
    ⚙️
    Stable Operation
    Fully automatic control, simple operation, and relatively low maintenance workload.
    🏗️
    Simple Installation
    No boiler room, chimney, or fuel storage required. Small footprint and low infrastructure costs.
    🛡️
    Good Safety Profile
    Operates at atmospheric or low pressure, eliminating explosion risks compared to steam boilers.
    Part V: Typical Application Industries
    🧪
    Chemical Industry
    Heating for reaction kettles, distillation, concentration, polymerization.
    🏭
    Plastics & Rubber Industry
    Heating for hot pressing, extrusion, vulcanization molding.
    🧵
    Textile & Dyeing Industry
    Heat supply for heat setting machines, dryers, dyeing machines.
    🍞
    Food Industry
    Heat supply for ovens, fryers, sterilizers.
    🧱
    Building Materials Industry
    Asphalt heating, concrete curing.
    🪵
    Wood Processing
    Timber drying, hot platen heating.
    Specification
    Parameter UNIT MODEL
    YWDR0.12 YWDR0.18 YWDR0.24 YWDR0.4 YWDR0.6 YWDR0.8 YWDR1.2
    Temp control range ℃ Inlet water temperature +45℃–300℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Heating power KW 120 180 240 400 600 800 1200
    Motor power KW 5.5 7.5 7.5 11 22 22 37
    Pump flow m³/h 25 30 30 45 100 100 160
    Pump head m 35 48 48 40 55 55 50
    Power Input KW 125.5 187.5 247.5 411 622 822 1237
    Circulating oil pipe Inch 2" (DN50) 2.5" (DN65) 2.5" (DN65) 3" (DN80) 4" (DN100) 4" (DN125) 6" (DN150)
    Distribution Cabinet Installation Formats Integration Integration Integration Single Single Single Single
    Size (L×W×H) mm 2400×1150×1800 2400×1200×2000 2400×1250×2000 2900×1500×2600 2900×1900×2900 3000×2000×3100 2600×1900×2900
    3000×1900×1600
    Flowchart
    flow
    Products Detail
    Electric Heating Thermal Oil Boiler (1)
    Electric Heating Thermal Oil Boiler (2)
    Electric Heating Thermal Oil Boiler (3)
    Frequently Asked Questions (FAQ)
    Q What is the maximum operating temperature of the electric heating thermal oil boiler?
    The electric heating thermal oil boiler supports a temperature control range from inlet water temperature +45°C up to 300°C, with PID precision control accuracy within ±1°C, making it suitable for a wide range of industrial heating processes.
    Q What type of heat transfer medium is used in the system?
    The system uses thermo conductive oil (thermal oil) as the heat transfer medium. The thermal oil circulates in a closed-loop circuit, delivering heat efficiently to the connected process equipment while being isolated from air to prevent oxidation.
    Q What safety protection features are included?
    The system is equipped with comprehensive safety protections, including over temperature protection, low oil level protection, flow/pressure protection, overpressure relief via safety valve, and full electrical protection (over current, short circuit, phase loss, and leakage). Alarm functions cover pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating conditions.
    Q Does the electric thermal oil boiler require a dedicated boiler room?
    No. Unlike traditional fuel or gas boilers, the electric heating thermal oil boiler does not require a boiler room, chimney, or fuel storage facilities. It has a small footprint and low infrastructure requirements, making it ideal for installation directly within workshops or production areas.
    Q What industries are best suited for this type of heating system?
    The electric heating thermal oil boiler is widely used across multiple industries including chemical processing (reaction kettles, distillation), plastics and rubber (extrusion, vulcanization), textile and dyeing (heat setting, drying), food processing (ovens, fryers), building materials (asphalt heating, concrete curing), and wood processing (timber drying, hot platen heating).
    Q What heating power options are available and what is the power supply requirement?
    The system is available in seven models with heating power ranging from 120 KW (YWDR0.12) up to 1200 KW (YWDR1.2). All models operate on AC 380V / 50Hz power supply. Smaller models (up to YWDR0.24) feature an integrated distribution cabinet, while larger models (YWDR0.4 and above) use a separate single distribution cabinet configuration.