0102030405
Electric Thermal Oil Heater from China Suppliers - High-Efficiency Industrial Heating Solutions from Factory
Part I: Working Principle
The system operates as a closed-loop circuit:
-
1
Heating: Electrical energy is converted into thermal energy via electric heating elements, which directly transfer heat to the organic heat transfer fluid (thermal oil).
-
2
Circulation: The high-temperature thermal oil is driven by a circulating pump and flows through the piping system.
-
3
Heat Release: The high-temperature thermal oil passes through the user's heat-consuming equipment (e.g., reaction kettles, heated platens, drying ovens), transferring its heat to the process medium.
-
4
Return: The cooled thermal oil returns to the heater to be reheated, thus beginning the next cycle.
Part II: Core System Components
1. Heating System
- Electric Heating Elements: The core heating components, typically made of stainless steel or high-temperature resistant alloy, directly immersed in the oil.
- Electrical Control Cabinet: Contains circuit breakers, contactors, SCR power regulators (for power modulation), protective devices, etc., for controlling and distributing electrical power.
2. Thermal Oil Circulation System
- Circulating Pump: Provides the motive force to ensure forced circulation of the thermal oil throughout the system.
- Expansion Tank: Accommodates the volumetric expansion of the thermal oil when heated and isolates it from air to prevent oxidation.
- Storage Tank: Used for storing the thermal oil during system maintenance.
3. Control and Safety Protection Systems
- Temperature Control: Utilizes PID intelligent temperature controllers for precise control of the outlet oil temperature.
⚙️ Multiple Safety Protections:
🌡️
Over Temperature Protection: Monitors oil temperature and automatically cuts power if it exceeds the set value.
💧
Low Oil Level Protection: Prevents dry-firing of the heating elements.
🔄
Flow/Pressure Protection: Monitors the operating status of the circulating pump; alarms and stops heating in case of insufficient flow.
⚠️
Overpressure Protection: Relieves pressure via a safety valve.
⚡
Electrical Protection: Over current, short circuit, phase loss, and leakage protection.
Part III: Main Advantages
🌿
Environmentally Friendly & Clean
Zero emissions, no combustion exhaust, smoke, dust, or noise pollution. Suitable for indoor installation within workshops.
⚡
High Thermal Efficiency
Direct conversion of electrical energy to thermal energy results in equipment efficiency often exceeding 95%.
🎯
Precise Temperature Control
Advanced PID control enables temperature regulation accuracy within ±1°C, with smooth heating and stable temperature holding.
🔧
Stable Operation
Fully automatic control, simple operation, and relatively low maintenance workload.
🏗️
Simple Installation
No boiler room, chimney, or fuel storage needed. Small footprint and low infrastructure costs.
🛡️
Good Safety Profile
Operates at atmospheric or low pressure, eliminating explosion risks compared to steam boilers.
Part V: Typical Application Industries
🧪
Chemical Industry
Heating for reaction kettles, distillation, concentration, polymerization.
🏭
Plastics & Rubber Industry
Heating for hot pressing, extrusion, vulcanization molding.
🧵
Textile & Dyeing Industry
Heat supply for heat setting machines, dryers, dyeing machines.
🍞
Food Industry
Heat supply for ovens, fryers, sterilizers.
🧱
Building Materials Industry
Asphalt heating, concrete curing.
🪵
Wood Processing
Timber drying, hot platen heating.
Specification
| Parameter | UNIT | MODEL | ||||||
| YWDR0.12 | YWDR0.18 | YWDR0.24 | YWDR0.4 | YWDR0.6 | YWDR0.8 | YWDR1.2 | ||
| Temp control range | ℃ | Inlet water temperature +45℃–300℃ | ||||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||||
| Power supply | / | AC380V 50Hz | ||||||
| Heat transfer medium | / | Thermo conductive oil | ||||||
| Cooling method | / | Indirect Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | ||||||
| Heating power | KW | 120 | 180 | 240 | 400 | 600 | 800 | 1200 |
| Motor power | KW | 5.5 | 7.5 | 7.5 | 11 | 22 | 22 | 37 |
| Pump flow | m³/h | 25 | 30 | 30 | 45 | 100 | 100 | 160 |
| Pump head | m | 35 | 48 | 48 | 40 | 55 | 55 | 50 |
| Power Input | KW | 125.5 | 187.5 | 247.5 | 411 | 622 | 822 | 1237 |
| Circulating oil pipe | Inch | 2"(DN50) | 2.5"(DN65) | 2.5"(DN65) | 3"(DN80) | 4"(DN100) | 4"(DN125) | 6"(DN150) |
| Distribution Cabinet Installation Formats | Integration | Integration | Integration | Single | Single | Single | Single | |
| Size (L×W×H) | mm | 2400×1150×1800 | 2400×1200×2000 | 2400×1250×2000 | 2900×1500×2600 | 2900×1900×2900 | 3000×2000×3100 | 2600×1900×2900 |
| 3000×1900×1600 | ||||||||
Flowchart
Products Detail
Frequently Asked Questions (FAQ)
Q What is the maximum operating temperature of the electric heating thermal oil boiler?
The electric heating thermal oil boiler supports a temperature control range from inlet water temperature +45°C up to 300°C, with a PID control accuracy of ±1°C, making it suitable for a wide range of industrial heating applications.
Q Is the electric heating thermal oil boiler safe to operate?
Yes. The system is equipped with multiple safety protections including over-temperature protection, low oil level protection, flow/pressure monitoring, overpressure relief via safety valve, and full electrical protection (over current, short circuit, phase loss, and leakage). It operates at atmospheric or low pressure, eliminating explosion risks associated with steam boilers.
Q What power supply is required for this system?
The electric heating thermal oil boiler requires an AC 380V, 50Hz power supply. Total power input ranges from 125.5 KW (YWDR0.12 model) up to 1,237 KW (YWDR1.2 model), depending on the selected model.
Q What industries are best suited for using an electric heating thermal oil boiler?
This system is widely used across multiple industries including chemical, plastics & rubber, textile & dyeing, food processing, building materials, and wood processing. Any industry requiring precise, clean, and stable high-temperature heat supply can benefit from this equipment.
Q Does the installation require a boiler room or special infrastructure?
No. One of the key advantages of the electric heating thermal oil boiler is its simple installation requirements. There is no need for a dedicated boiler room, chimney, or fuel storage facilities. The compact footprint and low infrastructure cost make it ideal for workshop or indoor installation.
Q How does the system achieve such high thermal efficiency?
The system directly converts electrical energy into thermal energy through immersed electric heating elements, eliminating combustion losses. This direct energy conversion method achieves an inherent equipment efficiency that often exceeds 95%, ensuring minimal energy waste during operation.