0102030405
Electric Thermal Oil Heater from China Suppliers - Efficient Heating Solutions by Leading Factory
Part I: Working Principle
-
1HeatingElectrical energy is converted into thermal energy via electric heating elements, which directly transfer heat to the organic heat transfer fluid (thermal oil).
-
2CirculationThe high-temperature thermal oil is driven by a circulating pump and flows through the piping system.
-
3Heat ReleaseThe high-temperature thermal oil passes through the user's heat-consuming equipment (e.g., reaction kettles, heated platens, drying ovens), transferring its heat to the process medium.
-
4ReturnThe cooled thermal oil returns to the heater to be reheated, thus beginning the next cycle.
Part II: Core System Components
⚡ 1. Heating System
- Electric Heating Elements: The core heating components, typically made of stainless steel or high-temperature resistant alloy, directly immersed in the oil.
- Electrical Control Cabinet: Contains circuit breakers, contactors, SCR power regulators (for power modulation), protective devices, etc., for controlling and distributing electrical power.
🔄 2. Thermal Oil Circulation System
- Circulating Pump: Provides the motive force to ensure forced circulation of the thermal oil throughout the system.
- Expansion Tank: Accommodates the volumetric expansion of the thermal oil when heated and isolates it from air to prevent oxidation.
- Storage Tank: Used for storing the thermal oil during system maintenance.
🛡 3. Control and Safety Protection Systems
- Temperature Control: Utilizes PID intelligent temperature controllers for precise control of the outlet oil temperature.
-
Multiple Safety Protections:
- Over-temperature Protection: Monitors oil temperature and automatically cuts power if it exceeds the set value.
- Low Oil Level Protection: Prevents dry-firing of the heating elements.
- Flow/Pressure Protection: Monitors the operating status of the circulating pump; alarms and stops heating in case of insufficient flow.
- Overpressure Protection: Relieves pressure via a safety valve.
- Electrical Protection: Over current, short circuit, phase loss, and leakage protection.
Part III: Main Advantages
🌿 Environmentally Friendly & Clean
Zero emissions, no combustion exhaust, smoke, dust, or noise pollution. Suitable for areas with strict environmental regulations and for indoor installation.
⚡ High Thermal Efficiency
Direct conversion of electrical energy to thermal energy results in high equipment efficiency, often exceeding 95%.
🎯 Precise Temperature Control
Advanced PID control enables temperature regulation accuracy within ±1°C, allowing for smooth heating and stable temperature holding.
⚙️ Stable Operation
Fully automatic control, simple operation, and relatively low maintenance workload.
🏗️ Simple Installation
No need for a boiler room, chimney, or fuel storage facilities. Requires a small footprint and has low infrastructure costs.
✅ Good Safety Profile
Operates at atmospheric or low pressure, eliminating explosion risks compared to steam boilers.
Part V: Typical Application Industries
🧪
Chemical Industry
Heating for reaction kettles, distillation, concentration, polymerization.
🏭
Plastics & Rubber Industry
Heating for hot pressing, extrusion, vulcanization molding.
🧵
Textile & Dyeing Industry
Heat supply for heat setting machines, dryers, dyeing machines.
🍽️
Food Industry
Heat supply for ovens, fryers, sterilizers.
🧱
Building Materials Industry
Asphalt heating, concrete curing.
🪵
Wood Processing
Timber drying, hot platen heating.
Specification
| Parameter | UNIT | MODEL | ||||||
|---|---|---|---|---|---|---|---|---|
| YWDR0.12 | YWDR0.18 | YWDR0.24 | YWDR0.4 | YWDR0.6 | YWDR0.8 | YWDR1.2 | ||
| Temp control range | ℃ | Inlet water temperature +45℃–300℃ | ||||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||||
| Power supply | / | AC380V 50Hz | ||||||
| Heat transfer medium | / | Thermo conductive oil | ||||||
| Cooling method | / | Indirect Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | ||||||
| Heating power | KW | 120 | 180 | 240 | 400 | 600 | 800 | 1200 |
| Motor power | KW | 5.5 | 7.5 | 7.5 | 11 | 22 | 22 | 37 |
| Pump flow | m³/h | 25 | 30 | 30 | 45 | 100 | 100 | 160 |
| Pump head | m | 35 | 48 | 48 | 40 | 55 | 55 | 50 |
| Power Input | KW | 125.5 | 187.5 | 247.5 | 411 | 622 | 822 | 1237 |
| Circulating oil pipe | Inch | 2" (DN50) | 2.5" (DN65) | 2.5" (DN65) | 3" (DN80) | 4" (DN100) | 4" (DN125) | 6" (DN150) |
| Distribution Cabinet Installation Formats | Integration | Integration | Integration | Single | Single | Single | Single | |
| Size (L×W×H) | mm | 2400×1150×1800 | 2400×1200×2000 | 2400×1250×2000 | 2900×1500×2600 | 2900×1900×2900 | 3000×2000×3100 | 2600×1900×2900 |
| 3000×1900×1600 | ||||||||
Flowchart
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the maximum operating temperature of an electric heating thermal oil boiler?
The electric heating thermal oil boiler supports a temperature control range from inlet water temperature +45°C up to 300°C, with PID precision control accuracy of ±1°C, making it suitable for a wide range of industrial heating processes.
Q
How does the electric thermal oil heater ensure safe operation?
The system is equipped with multiple safety protection mechanisms, including over-temperature protection, low oil level protection, flow/pressure protection, overpressure relief via safety valve, and comprehensive electrical protections (over current, short circuit, phase loss, and leakage). These systems work together to ensure safe and reliable continuous operation.
Q
What are the main advantages of an electric thermal oil heater compared to a steam boiler?
Unlike steam boilers, electric thermal oil heaters operate at atmospheric or low pressure, eliminating explosion risks. They produce zero emissions, require no boiler room or chimney, have a smaller footprint, and offer precise temperature control within ±1°C. Thermal efficiency typically exceeds 95%, making them a cleaner and more cost-effective solution.
Q
Which industries are best suited for electric heating thermal oil boilers?
Electric heating thermal oil boilers are widely used across many industries, including chemical processing (reaction kettles, distillation), plastics and rubber (extrusion, vulcanization), textile and dyeing (heat setting, drying), food processing (ovens, fryers), building materials (asphalt heating, concrete curing), and wood processing (timber drying, hot platen heating).
Q
What heating power options are available, and how do I choose the right model?
Available models range from 120 KW (YWDR0.12) to 1200 KW (YWDR1.2), covering a wide spectrum of industrial requirements. Model selection should be based on your required heating capacity, process temperature, circulating flow rate, and available electrical supply. Our technical team can assist you in selecting the most suitable model for your specific application.
Q
What type of thermal oil (heat transfer fluid) should be used, and how is it maintained?
The system uses thermo-conductive oil as the heat transfer medium. It is recommended to use high-quality, heat-stable thermal oil rated for the required operating temperature. The expansion tank isolates the oil from air to prevent oxidation and degradation. Regular oil sampling and analysis are advised to monitor oil quality, and the storage tank allows safe drainage during system maintenance or oil replacement.