Leave Your Message

China Water Temperature Controller: Superior Heat Conduction, Eco-Friendly, PID Controlled - Reliable Suppliers & Factory

The water temperature controller machine, a leading product from China, utilizes water as a highly efficient heat-conduction medium. Through advanced PID control, it automatically regulates temperature, resulting in enhanced performance compared to oil-based systems. With water's superior specific heat capacity, this machine ensures exceptional heat conduction efficiency under identical temperature regulation conditions. Additionally, this user-friendly solution is clean and pollution-free, making it an ideal choice for various applications. As a trusted factory and supplier, we are committed to delivering high-quality temperature control solutions to meet your needs

    Product Feature
    • 🌡️ Temperature Range: 50℃ – 180℃
    • ⚡ Power Range: 6KW – 96KW
    • 🖥️ Control Method: PC board micro-controller, PLC touch screen controls, Temperature control meter. Temperature control accuracy: ±0.5℃
    • 🛡️ Safety Features: High and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, explosion-proof design
    • 🏭 Application Industries: Plastic industry, rubber industry, roller temperature control, composite materials industry, automotive industry, food and pharmaceutical industry, etc.
    • 🔧 Special Features: Remote communication function (TCP/RTU), blow back water return function, timed startup and shutdown function, and other customized functions
    Core Working Principle and System Composition
    💡 A water temperature control unit is essentially a closed-loop heating system.
    1. Operating Cycle
    • Media Circulation: The circulation pump draws low-temperature water from the system (or expansion tank) and forces it into the heater (e.g., electric heating tubes), where it is rapidly heated to the set temperature.
    • Heat Output: The high-temperature hot water is pumped to the user end (e.g., mold channels), transferring heat to the target object via heat exchange.
    • Return Water & Temperature Control: The return water, cooled after releasing heat, is pumped back to the heater for reheating. Temperature sensors (e.g., PT100) monitor the outlet or return water temperature in real-time, sending signals to the PID temperature controller. The controller precisely adjusts the heater's output power (e.g., via SSR solid-state relays using PID logic) to achieve high-precision constant temperature control, typically within ±0.5°C or even ±0.1°C.
    2. Core System Components
    🔥 Heating System
    • Electric Heating (Most Common): Stainless steel electric heating tubes with segmented power control.
    • Gas/Steam Heating: Suitable for very high-power applications or sites with existing steam/gas supply.
    • Circulation Power System: High-temperature hot water pump (typically magnetic drive or mechanical seal pump) providing stable media circulation force.
    🎛️ Control System
    • Core: High-precision PID temperature controller (touch screen or digital display).
    • Key Components: Solid-state relays (SSR), contactors, temperature sensors, pressure sensors, flow switches.
    🔒 Safety & Auxiliary Systems
    • Safety Protections: Low water/flow protection, over-temperature protection, pump overload protection, over-pressure protection, leakage/short-circuit protection.
    • Auxiliary Components: Expansion tank (compensates for media thermal expansion), filter, vent valve, piping, and insulation.
    🏗️ Core Application Scenarios
    • Plastics Industry (Primary Application): Heating and temperature stabilization for molds in injection molding, extrusion molding, blow molding, and thermoforming.
    • Rubber Industry: Heating for molds in platen vulcanizing presses and rubber injection molding machines.
    • Die-Casting Industry: Preheating and temperature maintenance for molds used in magnesium, aluminum, and zinc alloy die-casting.
    • Chemical & Pharmaceutical: Temperature control and heat maintenance for reaction kettles and fermentation tanks.
    • Composite Materials: Heating for SMC/BMC molding presses and carbon fiber prepreg curing ovens.
    • Printing & Roller Applications: Temperature control for printing rolls and coating rolls.
    Typical Industrial Applications
    16
    15
    14
    Schematic Diagram
    Schematic Diagram
    Specification
    Parameter UNIT MODEL
    SWM-05 SWM-10 SWM-20 SWM-30 SWM-40
    Temp control range ℃ Inlet water temperature +15℃–120℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Water
    Cooling method / Direct Cooling
    Alarm function / Pump reversal / Water shortage / Overpressure / Overload
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m³/h 6 6 10 14 15
    Pump head m 18 18 20 18 35
    Power Input KW 6.33 9.75 13.5 26.2 39
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating water pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size (L×W×H) mm 810×325×610 810×325×610 810×325×610 1170×450×950 1500×500×1100
    Products Detail
    Industrial water mold temperature controller
    Mold temperature controller
    Mold temperature controller
    Frequently Asked Questions (FAQ)
    ❓ What is the temperature control accuracy of this water temperature control unit?
    The unit delivers high-precision temperature control with an accuracy of ±0.5℃ under standard operating conditions. With advanced PID control logic and SSR solid-state relays, certain configurations can achieve up to ±0.1°C, making it suitable for demanding industrial applications.
    ❓ What industries is this water mold temperature controller suitable for?
    This unit is widely used across plastics injection molding, rubber vulcanizing, die-casting (aluminum, magnesium, zinc alloys), chemical and pharmaceutical reaction kettles, composite material molding (SMC/BMC/carbon fiber), printing rolls, and food processing industries.
    ❓ What safety protections are built into the unit?
    The system is equipped with comprehensive safety features including high and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, low water/flow protection, over-temperature and over-pressure protection, and leakage/short-circuit protection. An explosion-proof design is also available.
    ❓ Does the unit support remote monitoring or communication?
    Yes. The unit supports remote communication functions via TCP/RTU protocols, enabling integration with factory automation systems or remote monitoring platforms. Timed startup/shutdown functions and customized communication interfaces are also available upon request.
    ❓ What is the available power range and how do I choose the right model?
    The heating power ranges from 6KW to 96KW across different models (SWM-05 to SWM-40 and beyond). Selection depends on your required temperature range, mold volume, heat loss, and cycle time. For example, the SWM-05 offers 6KW heating with a pump flow of 6 m³/h, while the SWM-40 provides 36KW with a pump flow of 15 m³/h. Please contact us for a tailored recommendation.
    ❓ What is the heat transfer medium used, and can it be customized?
    The standard heat transfer medium is water, suitable for temperature ranges up to 120℃ above the inlet water temperature. For applications requiring higher temperatures (up to 180℃), specialized thermal oil or pressurized water systems may be considered. Please consult with our technical team for customized solutions based on your specific process requirements.