China Water Temperature Controller Machine - Efficient Heat Conduction, PID Control, Suppliers & Factory Direct

Introducing our state-of-the-art water temperature controller machine, designed for optimal heat conduction efficiency. Utilizing water as a heat-conduction medium, our system employs advanced PID control to automatically regulate temperature. Compared to oil-based systems, water's superior specific heat capacity ensures enhanced performance under identical temperature conditions. This user-friendly product is not only clean and eco-friendly but also ideal for various industrial applications. As a leading factory and a trusted supplier in China, we are committed to delivering high-quality solutions that meet your temperature control needs

    Product Feature

    Temperature Range
    50℃ - 180℃
    Power Range
    6KW - 96KW
    Control Method
    PC board micro-controller, PLC touch screen controls, Temperature control 4 meter. Temperature control accuracy: ±0.5℃
    Safety Features
    High/low voltage, phase sequence, pump overload, medium impurity filtration protection, explosion-proof design.
    Application Industries
    Plastic industry, rubber industry, roller temperature control, composite materials, automotive, food & pharmaceutical, etc.
    Special Features
    Remote communication (TCP/RTU), blow back water return, timed startup/shutdown, and customized functions.

    Core Working Principle and System Composition

    A water temperature control unit is essentially a closed-loop heating system:

    1. Operating Cycle

    • Media Circulation: The circulation pump draws low-temperature water from the system (or expansion tank) and forces it into the heater (e.g., electric heating tubes), where it is rapidly heated to the set temperature.
    • Heat Output: The high-temperature hot water is pumped to the user end (e.g., mold channels), transferring heat to the target object via heat exchange.
    • Return Water & Temperature Control: The return water, cooled after releasing heat, is pumped back to the heater for reheating. Temperature sensors (e.g., PT100) monitor the outlet or return water temperature in real-time, sending signals to the PID temperature controller. The controller precisely adjusts the heater's output power (e.g., via SSR solid-state relays using PID logic) to achieve high-precision constant temperature control, typically within ±0.5°C or even ±0.1°C.

    2. Core System Components

    Heating System:

    • Electric Heating (Most Common): Stainless steel electric heating tubes with segmented power control.
    • Gas/Steam Heating: Suitable for very high-power applications or sites with existing steam/gas supply.
    • Circulation Power System: High-temperature hot water pump (typically magnetic drive or mechanical seal pump) providing stable media circulation force.

    Control System:

    • Core: High-precision PID temperature controller (touch screen or digital display).
    • Key Components: Solid-state relays (SSR), contactors, temperature sensors, pressure sensors, flow switches.

    Safety & Auxiliary Systems:

    • Safety Protections: Low water/flow protection, over-temperature protection, pump overload protection, over-pressure protection, leakage/short-circuit protection.
    • Auxiliary Components: Expansion tank (compensates for media thermal expansion), filter, vent valve, piping, and insulation.

    Core Application Scenarios

    • Plastics Industry (Primary Application): Heating and temperature stabilization for molds in injection molding, extrusion molding, blow molding, and thermoforming.
    • Rubber Industry: Heating for molds in platen vulcanizing presses and rubber injection molding machines.
    • Die-Casting Industry: Preheating and temperature maintenance for molds used in magnesium, aluminum, and zinc alloy die-casting.
    • Chemical & Pharmaceutical: Temperature control and heat maintenance for reaction kettles and fermentation tanks.
    • Composite Materials: Heating for SMC/BMC molding presses and carbon fiber prepreg curing ovens.
    • Printing & Roller Applications: Temperature control for printing rolls and coating rolls.

    Typical Industrial Applications

    16
    15
    14

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter UNIT MODEL
    SWM-05 SWM-10 SWM-20 SWM-30 SWM-40
    Temp control range ℃ Inlet water temperature +15℃-120℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Water
    Cooling method / Direct Cooling
    Alarm function / Pump reversal / Water shortage / Overpressure / Overload
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m3/h 6 6 10 14 15
    Pump head m 18 18 20 18 35
    Power Input KW 6.33 9.75 13.5 26.2 39
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating water pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size(LxWxH) mm 810*325*610 810*325*610 810*325*610 1170*450*950 1500*500*1100

    Products Detail

    Industrial water mold temperature controller
    Mold temperature controller
    Mold temperature controller

    Frequently Asked Questions

    What is the temperature range of the water temperature control unit?
    The standard temperature control range of the unit spans from 50℃ to 180℃. Depending on the specific model configuration, the inlet water temperature range supports +15℃ to 120℃.
    What safety protection features are included?
    The system features comprehensive built-in safety protections, including high and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, and an explosion-proof design.
    Which industries benefit most from this temperature controller?
    It is widely utilized in the plastics industry (injection and extrusion molding), rubber industry, roller temperature control, composite materials industry, automotive manufacturing, and the food and pharmaceutical sectors.
    How does the closed-loop heating cycle achieve high precision?
    The unit circulates water through a closed loop using a high-temperature pump. Real-time temperature sensors (e.g., PT100) continuously monitor return water and output signals to a PID micro-controller, which dynamically adjusts heating power via solid-state relays (SSR) to keep accuracy within ±0.5℃.
    Does the unit support remote monitoring and system communication?
    Yes, it features remote communication functions using TCP/RTU protocols. It also supports timed startup and shutdown functions alongside other customized requirements.
    What options are available for the heating and control systems?
    The heating system utilizes stainless steel electric heating tubes with segmented power control (or optional gas/steam heating). The control system offers choices between PC board micro-controllers and PLC touch screens.