0102030405
China Water Temperature Controller Factory Suppliers - PID Control for Efficient Heat Conduction
Product Feature
- 1 Temperature Range: 50℃ – 180℃
- 2 Power Range: 6KW – 96KW
- 3 Control Method: PC board micro-controller, PLC touch screen controls, Temperature control meter. Temperature control accuracy: ±0.5℃
- 4 Safety Features: High and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, explosion-proof design
- 5 Application Industries: Plastic industry, rubber industry, roller temperature control, composite materials industry, automotive industry, food and pharmaceutical industry, etc.
- 6 Special Features: Remote communication function (TCP/RTU), blow back water return function, timed startup and shutdown function, and other customized functions
Core Working Principle and System Composition
A water temperature control unit is essentially a closed-loop heating system:
1. Operating Cycle
Media Circulation
- The circulation pump draws low-temperature water from the system (or expansion tank) and forces it into the heater (e.g., electric heating tubes), where it is rapidly heated to the set temperature.
- The high-temperature hot water is pumped to the user end (e.g., mold channels), transferring heat to the target object via heat exchange.
- The return water, cooled after releasing heat, is pumped back to the heater for reheating. Temperature sensors (e.g., PT100) monitor the outlet or return water temperature in real-time, sending signals to the PID temperature controller. The controller precisely adjusts the heater's output power (e.g., via SSR solid-state relays using PID logic) to achieve high-precision constant temperature control, typically within ±0.5°C or even ±0.1°C.
2. Core System Components
Heating System
- Electric Heating (Most Common): Stainless steel electric heating tubes with segmented power control.
- Gas/Steam Heating: Suitable for very high-power applications or sites with existing steam/gas supply.
- Circulation Power System: High-temperature hot water pump (typically magnetic drive or mechanical seal pump) providing stable media circulation force.
- Core: High-precision PID temperature controller (touch screen or digital display).
- Key Components: Solid-state relays (SSR), contactors, temperature sensors, pressure sensors, flow switches.
- Safety Protections: Low water/flow protection, over-temperature protection, pump overload protection, over-pressure protection, leakage/short-circuit protection.
- Auxiliary Components: Expansion tank (compensates for media thermal expansion), filter, vent valve, piping, and insulation.
- Plastics Industry (Primary Application): Heating and temperature stabilization for molds in injection molding, extrusion molding, blow molding, and thermoforming.
- Rubber Industry: Heating for molds in platen vulcanizing presses and rubber injection molding machines.
- Die-Casting Industry: Preheating and temperature maintenance for molds used in magnesium, aluminum, and zinc alloy die-casting.
- Chemical & Pharmaceutical: Temperature control and heat maintenance for reaction kettles and fermentation tanks.
- Composite Materials: Heating for SMC/BMC molding presses and carbon fiber prepreg curing ovens.
- Printing & Roller Applications: Temperature control for printing rolls and coating rolls.
Typical Industrial Applications
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | ||||
| SWM-05 | SWM-10 | SWM-20 | SWM-30 | SWM-40 | ||
| Temp control range | ℃ | Inlet water temperature +15℃–120℃ | ||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Water | ||||
| Cooling method | / | Direct Cooling | ||||
| Alarm function | / | Pump reversal / Water shortage / Overpressure / Overload | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m³/h | 6 | 6 | 10 | 14 | 15 |
| Pump head | m | 18 | 18 | 20 | 18 | 35 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating water pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size (L×W×H) | mm | 810×325×610 | 810×325×610 | 810×325×610 | 1170×450×950 | 1500×500×1100 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the temperature control range of this water temperature control unit?
The unit supports a temperature control range of 50℃ to 180℃, with a control accuracy of ±0.5℃. For models with PID control, accuracy can reach ±1℃ or better, making it suitable for precision industrial processes.
Q
Which industries are water mold temperature controllers most suitable for?
These units are widely used in the plastics industry (injection molding, extrusion, blow molding), rubber industry, die-casting, chemical and pharmaceutical sectors, composite materials manufacturing, and printing and roller applications where precise temperature control is essential.
Q
What safety protections are built into the water temperature controller?
The unit includes comprehensive safety features: high and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, over-temperature and over-pressure alarms, water shortage detection, and an explosion-proof design for hazardous environments.
Q
What power supply is required, and what power range is available?
All models operate on AC 380V / 50Hz power supply. The available heating power ranges from 6KW to 96KW, with total power input ranging from 6.33KW (SWM-05) to 39KW (SWM-40) depending on the model selected.
Q
Does the unit support remote monitoring or communication functions?
Yes. The water temperature controller supports remote communication via TCP/RTU protocols, enabling integration with factory automation systems. Additional features include a blow-back water return function, timed startup and shutdown, and other customizable functions based on specific requirements.
Q
How does the PID closed-loop control system maintain temperature accuracy?
The system uses PT100 temperature sensors to monitor outlet or return water temperature in real-time. Signals are sent to a high-precision PID controller, which dynamically adjusts heater output power via SSR solid-state relays. This closed-loop feedback mechanism ensures stable temperature control, typically within ±0.5°C and in high-precision configurations within ±0.1°C.