0102030405
China Water Mold Temperature Controller: Efficient PID Control from Trusted Suppliers and Factory Solutions
Product Feature
- 🌡️Temperature Range: 50℃ – 180℃
- ⚡Power Range: 6KW – 96KW
- 🖥️Control Method: PC board micro-controller, PLC touch screen controls, Temperature control meter. Temperature control accuracy: ±0.5℃
- 🛡️Safety Features: High and low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, explosion-proof design
- 🏭Application Industries: Plastic industry, rubber industry, roller temperature control, composite materials industry, automotive industry, food and pharmaceutical industry, etc.
- 🔧Special Features: Remote communication function (TCP/RTU), blow back water return function, timed startup and shutdown function, and other customized functions
Core Working Principle and System Composition
A water temperature control unit is essentially a closed-loop heating system:
1. Operating Cycle
- Media Circulation: The circulation pump draws low-temperature water from the system (or expansion tank) and forces it into the heater (e.g., electric heating tubes), where it is rapidly heated to the set temperature.
- Heat Output: The high-temperature hot water is pumped to the user end (e.g., mold channels), transferring heat to the target object via heat exchange.
- Return Water & Temperature Control: The return water, cooled after releasing heat, is pumped back to the heater for reheating. Temperature sensors (e.g., PT100) monitor the outlet or return water temperature in real-time, sending signals to the PID temperature controller. The controller precisely adjusts the heater's output power (e.g., via SSR solid-state relays using PID logic) to achieve high-precision constant temperature control, typically within ±0.5°C or even ±0.1°C.
2. Core System Components
🔥 Heating System
- Electric Heating (Most Common): Stainless steel electric heating tubes with segmented power control.
- Gas/Steam Heating: Suitable for very high-power applications or sites with existing steam/gas supply.
- Circulation Power System: High-temperature hot water pump (typically magnetic drive or mechanical seal pump) providing stable media circulation force.
🖥️ Control System
- Core: High-precision PID temperature controller (touch screen or digital display).
- Key Components: Solid-state relays (SSR), contactors, temperature sensors, pressure sensors, flow switches.
🛡️ Safety & Auxiliary Systems
- Safety Protections: Low water/flow protection, over-temperature protection, pump overload protection, over-pressure protection, leakage/short-circuit protection.
- Auxiliary Components: Expansion tank (compensates for media thermal expansion), filter, vent valve, piping, and insulation.
Core Application Scenarios
🏗️ Plastics IndustryHeating and temperature stabilization for molds in injection molding, extrusion molding, blow molding, and thermoforming.
🔩 Rubber IndustryHeating for molds in platen vulcanizing presses and rubber injection molding machines.
🪙 Die-Casting IndustryPreheating and temperature maintenance for molds used in magnesium, aluminum, and zinc alloy die-casting.
⚗️ Chemical & PharmaceuticalTemperature control and heat maintenance for reaction kettles and fermentation tanks.
🧵 Composite MaterialsHeating for SMC/BMC molding presses and carbon fiber prepreg curing ovens.
🖨️ Printing & RollerTemperature control for printing rolls and coating rolls.
Typical Industrial Applications
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | ||||
| SWM-05 | SWM-10 | SWM-20 | SWM-30 | SWM-40 | ||
| Temp control range | ℃ | Inlet water temperature +15℃–120℃ | ||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Water | ||||
| Cooling method | / | Direct Cooling | ||||
| Alarm function | / | Pump reversal / Water shortage / Overpressure / Overload | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m³/h | 6 | 6 | 10 | 14 | 15 |
| Pump head | m | 18 | 18 | 20 | 18 | 35 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating water pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size (L×W×H) | mm | 810×325×610 | 810×325×610 | 810×325×610 | 1170×450×950 | 1500×500×1100 |
Products Detail
Frequently Asked Questions (FAQ)
QWhat is the temperature control range of this water temperature control unit?
The unit supports a temperature control range of 50℃ to 180℃, with a control accuracy of ±0.5℃. For standard SWM series models, the range is inlet water temperature +15℃ up to 120℃ with PID accuracy of ±1℃.
QWhat industries is this water mold temperature controller suitable for?
It is widely used across multiple industries including plastics (injection/extrusion/blow molding), rubber, die-casting, chemical & pharmaceutical, composite materials, printing, and roller temperature control applications.
QWhat safety protections does the unit include?
The unit is equipped with comprehensive safety features including high/low voltage protection, phase sequence protection, pump overload protection, medium impurity filtration protection, over-temperature protection, over-pressure protection, low water/flow protection, and an explosion-proof design.
QWhat power supply is required, and what is the available heating power range?
The unit requires a standard AC 380V / 50Hz three-phase power supply. Heating power ranges from 6KW to 96KW depending on the model selected, covering both small and large industrial applications.
QDoes the unit support remote monitoring or communication functions?
Yes. The unit supports remote communication via TCP/RTU protocols, allowing integration with factory automation systems. It also features a timed startup/shutdown function and a blow-back water return function, with additional customized functions available upon request.
QWhat is the heat transfer medium used, and how does the cooling system work?
The heat transfer medium is water. The system uses a direct cooling method, where cooled return water is recirculated through the heater for reheating in a closed loop. An expansion tank is included to compensate for thermal expansion of the media during operation.