0102030405
China TCU Temperature Controller Machine | Reliable Suppliers & Factory for Efficient Thermal Management Solutions
Product Feature
A complete Temperature Control Unit (TCU) typically consists of the following components and operates according to a specific workflow.
1. Core Components
Circulation Pump: Drives the heat transfer fluid to circulate between the TCU and the user's equipment.
Heater: Typically electric heating elements, used to precisely heat the fluid when heat is required.
Heat Exchangers:
• Cooling Heat Exchanger: Transfers excess heat from the process fluid to a cooling medium, such as cooling water or a cryogenic fluid.
• Steam Heat Exchanger: (If a steam heat source is used).
Control System: The "brain" of the unit. It includes temperature sensors, a PID controller, and a Human-Machine Interface (HMI) for setting and maintaining the target temperature.
Expansion Tank: Accommodates the volumetric expansion and contraction of the fluid due to temperature changes, thereby stabilizing system pressure.
2. Typical Workflow
🔥 Heating Mode
When the process requires heating, the TCU activates the circulation pump and the heater. The heat transfer fluid is heated to the set temperature and then pumped into the reactor jacket or coil.
❄️ Cooling Mode
When the reaction is exothermic or cooling is required, the TCU turns off the heater and opens the valve for the cooling water or cryogenic medium. The heat is removed via the heat exchanger, and the cooled fluid is pumped back to the reactor.
🎯 Temperature Maintenance Mode
The PID controller dynamically adjusts the input of both heating and cooling to maintain a constant temperature.
Key Advantages of TCUs
🎯
High-Precision Control
Capable of achieving temperature control accuracy of ±0.5°C or even higher.
🌡️
Wide Temperature Range
Operating range from -120°C (special fluids) to +400°C (thermal oil), depending on the fluid used.
🔒
High Safety
A closed-loop system prevents the fluid from contacting the atmosphere, reducing risks of oxidation and contamination.
🔄
Improved Process Reproducibility
Precise temperature control is key to ensuring product quality and batch-to-batch consistency.
⚡
Increased Efficiency
Faster response times, more stable control, and lower energy consumption compared to direct steam/cooling water feeding.
Application Scenarios
Beyond chemical reactors, TCUs are widely used in:
💊
Pharmaceutical Industry
Temperature control for synthesis reactions, crystallization, and fermenters.
Temperature control for synthesis reactions, crystallization, and fermenters.
🔋
New Energy
Battery material production and fuel cell testing.
Battery material production and fuel cell testing.
🏭
Plastics and Rubber
Mold temperature control, extruders and calenders.
Mold temperature control, extruders and calenders.
🔬
Laboratories
Precise temperature control for small-scale reactors, bioreactors, viscometers, and other equipment.
Precise temperature control for small-scale reactors, bioreactors, viscometers, and other equipment.
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| TCU-20 | TCU-30 | TCU-40 | TCU-50 | TCU-75 | ||
| Temp control range | ℃ | Based on the temperature of the heat source and cold source provided by the customer | ||||
| Temp control accuracy | ℃ | PID±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Thermo conductive oil or water | ||||
| Heating method | / | Indirect Heating or direct heating | ||||
| Cooling method | / | Indirect Cooling or direct cooling | ||||
| Alarm function | / | Pump reversal / Overload / Abnormal heating | ||||
| Heating power | m² | Non standard customization | ||||
| Cooling power | m² | Non standard customization | ||||
| Motor power | KW | 1.5 | 2.2 | 3 | 4 | 5.5 |
| Pump flow | m³/h | 6 | 10 | 12.5 | 16 | 25 |
| Pump head | m | 28 | 28 | 30 | 32 | 35 |
| Power Input | KW | 1.5 | 2.2 | 3 | 4 | 5.5 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating oil or water pipe | Inch | 1" | 1" | 1-1/4" | 1-1/2" | 2" |
| Size (L×W×H) | mm | Non-standard integrated design | ||||
Products Detail
Frequently Asked Questions (FAQ)
Q What is a Temperature Control Unit (TCU) and how does it work?
A Temperature Control Unit (TCU) is an industrial device that precisely regulates the temperature of process equipment such as reactors, molds, and bioreactors. It works by circulating a heat transfer fluid (such as thermal oil or water) through the equipment. A PID controller continuously monitors the temperature and adjusts heating or cooling input to maintain the desired setpoint.
Q What temperature range can a TCU achieve?
Depending on the heat transfer fluid selected, TCUs can operate across a very wide range — from as low as -120°C using special cryogenic fluids, up to +400°C using thermal oil. The actual range for a specific unit is determined by the heat source and cold source provided by the customer.
Q What is the temperature control accuracy of your TCU models?
Our TCU models achieve a temperature control accuracy of PID ±1°C under standard operating conditions. Advanced configurations can reach ±0.5°C or higher precision, making them suitable for highly sensitive processes in pharmaceutical and laboratory applications.
Q What industries are TCUs commonly used in?
TCUs are used across a wide range of industries including chemical processing (reactor temperature control), pharmaceutical manufacturing (synthesis, crystallization, fermentation), new energy (battery material production, fuel cell testing), plastics and rubber (mold temperature control, extruders), and laboratory research (small-scale reactors, bioreactors, viscometers).
Q Can the TCU be customized for specific heating and cooling power requirements?
Yes. The heating power and cooling power of our TCUs are offered as non-standard customizations. We work closely with customers to design a unit that meets their specific process requirements, including custom pipe sizing, fluid type selection, and integrated design dimensions.
Q What safety features are built into the TCU?
Our TCUs include multiple built-in safety and alarm functions, such as pump reversal detection, motor overload protection, and abnormal heating alerts. The closed-loop fluid circulation system also prevents the heat transfer medium from contacting the atmosphere, minimizing risks of oxidation, contamination, and fluid degradation.