Product Description
Temperature Range: -50℃ to 300℃
Power Range: Heating 6KW-96KW / Cooling 3KW-200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability
Cooling Part
- Using brand scroll compressor (Copeland, Sanyo, Daikin, etc.)
- The internal copper pipe is welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories
Core Working Principle
Its operation is based on a closed-loop circulation system:
1. Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
2. Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
3. Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
4. Temperature Regulation:
• When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
• When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
• When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
• When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
5. Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
2. Broad Temperature Control Range: A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
4. High Efficiency and Energy Saving:
• Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient.
• Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
• Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient.
• Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
- • Field: Specific Application Scenarios
- Chemical & Pharmaceutical: Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
- Plastics & Rubber: Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
- Laboratory & Testing: Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
- New Energy: Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
- Semiconductor & Electronics: Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
- Food Industry: Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
- Other Industries: Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specifications
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dry Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m3/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size(LxWxH) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions
Q:
What is the temperature range of this combined heating and cooling machine?
The machine supports a temperature range from -50℃ to 300℃, depending on the model and the heat transfer medium selected.
Q:
What types of heat transfer mediums does the system use?
It typically uses water or thermo conductive oil as the circulation medium to regulate temperature based on specific application requirements.
Q:
How does the PID control system ensure precise temperature regulation?
The control system monitors return fluid temperature and uses PID logic to decide in real-time whether to activate heating or cooling, maintaining stability within ±0.1°C or better.
Q:
What are the main safety protections included in the machine?
It features built-in protections for pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating, complete with a clear fault display system.
Q:
What components are used in the cooling section?
The cooling system uses high-quality scroll compressors from leading brands like Copeland, Sanyo, and Daikin, along with copper pipes welded without oxygen.