0102030405
China Suppliers Factory Hot and Cold Unit - Integrated Thermal Circulator for Precise Temperature Control
Product Description
🌡️ Temperature Range: -50℃ ~ 300℃
⚡ Heating Power: 6KW – 96KW
❄️ Cooling Power: 3KW – 200KW
Basic Functions
🔥 Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- 304 stainless steel integrated pipe — reduces pipe resistance and carbon deposition
- Perfect safety protection and fault display system — no professional personnel needed for repair and maintenance
- PLC control — high reliability, strong anti-interference ability
❄️ Cooling Part
- Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- Internal copper pipe welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor — easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories — perfect safety
Core Working Principle
Its operation is based on a closed-loop circulation system:
- 1. Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
- 2. Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
- 3. Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
-
4. Temperature Regulation:
🔥 When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.❄️ When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
- 5. Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
- 🏗️ 1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
- 🌡️ 2. Broad Temperature Control Range: A single unit can cover a wide span from low to high temperatures. Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
- 🎯 3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
-
💡
4. High Efficiency and Energy Saving:Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
- 🚀 5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
- ⚗️ Chemical & Pharmaceutical: Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
- 🏭 Plastics & Rubber: Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
- 🔬 Laboratory & Testing: Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
- 🔋 New Energy: Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
- 💻 Semiconductor & Electronics: Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
- 🍫 Food Industry: Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
- 🖨️ Other Industries: Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dry Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size(LxWxH) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions (FAQ)
❓
What is the temperature control range of this combined heating and cooling machine?
The unit supports a wide temperature control range of -50°C to +300°C, depending on the model and heat transfer medium selected. Common configurations include -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C, making it suitable for both low-temperature and high-temperature process applications.
❓
What heat transfer fluids can be used in this system?
The system supports multiple heat transfer media depending on the model: thermal conductive oil is used for high-temperature oil-type models (up to 300°C), while water or glycol-water mixtures are used for water-type models (up to 120°C). The appropriate medium should be selected based on your process temperature requirements.
❓
How precise is the temperature control of this machine?
The unit uses PID intelligent control logic with a standard accuracy of ±1°C. Advanced models with optimized PID tuning can achieve temperature stability of ±0.1°C or better, meeting the stringent requirements of pharmaceutical, laboratory, and semiconductor applications.
❓
What industries and applications is this unit suitable for?
This combined heating and cooling machine is widely used across multiple industries, including chemical & pharmaceutical (reaction kettle temperature control, GMP processes), plastics & rubber (injection mold temperature control), laboratory & testing (rotary evaporators, calorimeters), new energy (battery and fuel cell testing), semiconductor & electronics (laser cooling, PCB equipment), food industry (chocolate tempering, sterilization cooling), and more.
❓
What safety protection features does the machine include?
The unit is equipped with a comprehensive safety protection and fault display system, including alarms for: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The PLC-based control system ensures high reliability and strong anti-interference performance, and no professional technician is required for routine maintenance.
❓
What is the difference between air-cooled and water-cooled condenser models?
Air-cooled models (using MCHE or finned tube condensers) do not require an external cooling water supply, making them easier to install and suitable for locations without water infrastructure. Water-cooled models (using shell-and-tube condensers) offer higher cooling efficiency and are preferred in environments with high ambient temperatures or where stable, high-capacity cooling is required. The choice depends on your facility conditions and cooling capacity needs.