0102030405
China Suppliers Factory Combined Heating and Cooling Machine for Precise Temperature Control in Labs and Industries
Product Description
🌡️ Temperature Range: -50℃ ~ 300℃
⚡ Heating Power: 6KW – 96KW
❄️ Cooling Power: 3KW – 200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability
Cooling Part
- Using brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- The internal copper pipe is welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories — perfect safety
Core Working Principle
Its operation is based on a closed-loop circulation system:
1
Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
2
Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
3
Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
4
Temperature Regulation:
- When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
- When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
5
Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
⚠️ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
🏗️ 1. Integrated Design, Saves Space
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
🌡️ 2. Broad Temperature Control Range
A single unit covers a wide span from low to high temperatures:
- -80°C to +200°C
- -40°C to +200°C
- -25°C to +200°C
- 0°C to +300°C
🎯 3. High-Precision Temperature Control
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
💡 4. High Efficiency and Energy Saving
The cooling system operates at full capacity for fast cooling. During stabilization, it can run at lower power to offset process heat. Advanced models can recover waste heat for pre-heating, further reducing energy consumption.
🚀 5. Increases Production Efficiency
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
⚗️
Chemical & Pharmaceutical: Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
🔧
Plastics & Rubber: Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
🔬
Laboratory & Testing: Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
🔋
New Energy: Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
💻
Semiconductor & Electronics: Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
🍫
Food Industry: Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
🏭
Other Industries: Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q What is the temperature range of this combined heating and cooling machine?
The unit supports a temperature range of -50°C to 300°C. Different models cover specific spans such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C, making it suitable for a wide variety of industrial and laboratory applications.
Q What heat transfer fluids are compatible with this system?
The system supports multiple heat transfer media depending on the model. Oil-type models use thermo conductive oil, while water-type models use water. Glycol-water mixtures can also be used depending on the operating temperature range required.
Q How accurate is the temperature control?
The system uses PID intelligent control logic for precise regulation, achieving a temperature accuracy of ±1°C under standard operation and up to ±0.1°C or better for advanced closed-loop configurations. This makes it ideal for sensitive chemical, pharmaceutical, and laboratory processes.
Q What industries can this combined heating and cooling unit be used in?
This unit is widely applied across many industries including Chemical & Pharmaceutical, Plastics & Rubber, Laboratory & Testing, New Energy (battery/motor testing), Semiconductor & Electronics, Food Industry, and other industrial sectors requiring precise temperature management.
Q What safety protections does the system include?
The unit is equipped with a comprehensive safety and fault display system covering: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The PLC-based control ensures high reliability and strong anti-interference capability, requiring no specialized personnel for routine maintenance.
Q What is the power supply requirement and available heating/cooling capacity?
All models operate on AC 380V / 50Hz. Heating power ranges from 6KW to 96KW, and cooling capacity ranges from 3KW to 200KW, with specific model outputs such as 13.95KW to 31.8KW cooling and 24KW to 36KW heating as shown in the specification table.