China Suppliers Factory Combined Heating and Cooling Machine for Precise Temperature Control in Laboratories and Industries
Product Description
Temperature Range
-50℃ - 300℃
Power Range
Heating Power: 6KW - 96KW
Cooling Power: 3KW - 200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability.
Cooling Part
- Using brand scroll compressor (Copeland, Sanyo, Daikin, etc.)
- The internal copper pipe is welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories Perfect safety
Core Working Principle
Its operation is based on a closed-loop circulation system:
The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
Main Features and Advantages
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.
Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m3/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size(LxWxH) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions
What is the temperature range of the combined heating and cooling machine?
The overall temperature range of the equipment is from -50℃ to 300℃. Depending on the model and the heat transfer medium used, the oil-based models support a range of 5℃ to 300℃, while the water-based models support 5℃ to 120℃.
What are the primary heat transfer mediums used?
The system uses either water or thermo conductive oil as the heat transfer medium, depending on the specific model and your required operational temperature range.
How does the integrated design benefit my production facility?
The integrated design combines both heating and chilling functions into a single unit. This eliminates the need to purchase separate units, saves valuable floor space, simplifies installation, and reduces piping connections.
What safety features are built into the system?
The machine features a comprehensive safety protection and fault display system. It includes protection alarms for pump reversal, oil shortage, overheating, motor overload, oil overflow, and abnormal heating, allowing for easy troubleshooting without specialized maintenance personnel.
How precise is the temperature regulation?
The system utilizes intelligent PID control logic to monitor and adjust the temperature in real-time. This ensures minimal temperature fluctuations, achieving high-precision control within ±1℃ (and up to ±0.1°C under stable closed-loop conditions).