Leave Your Message

China Suppliers Factory Combined Heating and Cooling Machine for Precise Temperature Control in Laboratories and Industries

,

Introducing our advanced hot and cold unit, also known as a thermal circulator, designed for optimal temperature control in various applications. This innovative system integrates both refrigeration and heating functionalities, ensuring precise and stable temperature management. Ideal for laboratories and industrial processes, our thermal circulators are perfect for maintaining the temperature of reactors, instruments, and testing chambers. As a leading factory in China, we are dedicated to providing high-quality temperature control solutions tailored to meet the needs of suppliers and industries worldwide.

,

    Product Description

    Temperature Range

    -50℃ - 300℃

    Power Range

    Heating Power: 6KW - 96KW
    Cooling Power: 3KW - 200KW

    Basic Functions

    Heating Part

    • Return oil temperature display
    • Start up automatic exhaust
    • Heating power gear adjustment
    • Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
    • Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
    • PLC control, high reliability, strong anti-interference ability.

    Cooling Part

    • Using brand scroll compressor (Copeland, Sanyo, Daikin, etc.)
    • The internal copper pipe is welded without oxygen
    • High efficiency evaporator and condenser
    • 304 SS stainless steel water tank
    • PC board self-optimized microprocessor, easy to operate
    • OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories Perfect safety

    Core Working Principle

    Its operation is based on a closed-loop circulation system:

    1. Circulating Medium

    The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).

    2. Pumping

    A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).

    3. Heat Exchange

    The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.

    4. Temperature Regulation

    When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.

    5. Return and Feedback

    The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.

    Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages

    1. Integrated Design, Saves Space

    Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.

    2. Broad Temperature Control Range

    A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.

    3. High-Precision Temperature Control

    Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.

    4. High Efficiency and Energy Saving

    Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.
    Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.

    5. Increases Production Efficiency

    Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields

    Field
    Specific Application Scenarios
    Chemical & Pharmaceutical
    Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    Plastics & Rubber
    Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    Laboratory & Testing
    Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    New Energy
    Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    Semiconductor & Electronics
    Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    Food Industry
    Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
    Other Industries
    Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
    16
    15
    14

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter UNIT MODEL
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃-300℃ 5℃-120℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dny Shell And Tube Type
    Condenser type / MCHE Or Finned Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m3/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size(LxWxH) mm 1200*1100*1250 1450*1250*1550 1200*1000*1250 1300*1180*1400 1200*1050*1250 1450*1200*1550 1200*950*1250 1300*1130*1400

    Products Detail

    Combined Heating and Cooling Machine01
    Combined Heating and Cooling Machine 02
    Combined Heating and Cooling Machine 03

    Frequently Asked Questions

    What is the temperature range of the combined heating and cooling machine?

    The overall temperature range of the equipment is from -50℃ to 300℃. Depending on the model and the heat transfer medium used, the oil-based models support a range of 5℃ to 300℃, while the water-based models support 5℃ to 120℃.

    What are the primary heat transfer mediums used?

    The system uses either water or thermo conductive oil as the heat transfer medium, depending on the specific model and your required operational temperature range.

    How does the integrated design benefit my production facility?

    The integrated design combines both heating and chilling functions into a single unit. This eliminates the need to purchase separate units, saves valuable floor space, simplifies installation, and reduces piping connections.

    What safety features are built into the system?

    The machine features a comprehensive safety protection and fault display system. It includes protection alarms for pump reversal, oil shortage, overheating, motor overload, oil overflow, and abnormal heating, allowing for easy troubleshooting without specialized maintenance personnel.

    How precise is the temperature regulation?

    The system utilizes intelligent PID control logic to monitor and adjust the temperature in real-time. This ensures minimal temperature fluctuations, achieving high-precision control within ±1℃ (and up to ±0.1°C under stable closed-loop conditions).