China Suppliers Factory Air Cooled Water Chiller for Efficient Industrial Cooling Solutions

Introducing our advanced water chiller, a compact and efficient solution that integrates a refrigeration system, water tank, and water pump into one unit. This innovative product is designed to cool circulating water to your desired low temperature, ensuring a stable supply of low-temperature water for industrial equipment. As a leading factory in China, we pride ourselves on providing high-quality products to our clients. Our water chillers are ideal for various applications, and as trusted suppliers, we guarantee exceptional performance and reliability. Upgrade your cooling system with our cutting-edge water chiller today!

    Product Feature
    • Adopt compressor imported from Europe and America
    • The copper pipe adopts oxygen free welding method
    • RS485 communication function to realize automatic management (optional)
    • Imported advanced components with long service life
    • Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
    • Control mode: imported microcomputer or PLC control (optional)
    • Perfect safety protection, fault display, repair and maintenance without professional personnel
    • High efficiency evaporator and condenser can save energy by more than 30%
    Working Principle and System Components
    1 Refrigeration Cycle (consistent with all compression refrigeration systems)
    • Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
    • The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
    • The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
    • The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
    2 Core Difference — The Air-Cooled Condenser
    • This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
    • The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
    3 System Composition (Highly Integrated)
    Main Unit:
    • The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
    Auxiliary Components:
    • Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
    • Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
    • Electrical Control Cabinet: Integrates control, protection, and display functions.
    Typical Industrial Applications
    🏭
    Plastics Industry
    Cooling for injection molding machine molds, directly impacting product quality and cycle time.
    ⚗️
    Chemical & Pharmaceutical
    Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
    🔧
    Machining & Lasers
    Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
    🍔
    Food & Beverage
    Cooling for mixing, fermentation, and packaging processes in production lines.
    💡
    Electronics Industry
    Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
    ⚡
    Energy & Metallurgy
    Transformer oil cooling, blast furnace auxiliary system cooling.
    16
    15
    14
    Schematic Diagram
    Schematic Diagram
    Specification
    Parameter UNIT MODEL
    SC-03AS SC-05AS SC-08AS SC-10AD SC-15AD SC-20AD SC-25AD SC-30AD SC-40AD SC-50AD SC-60AD
    Cooling Capacity Kcal/h 7216 11990 18748 24089 37965 50808.8 61683 74992 97678 116521 156249
    KW 8.39 13.95 21.8 28.01 44.15 59.08 71.72 87.2 113.58 135.49 181.68
    Power Input KW 3.6 5.5 8.6 11 17 22.8 27.7 33.7 42.8 51.1 68.8
    Running Current A 8.8 13.4 20.9 26.7 41.3 55.4 63.1 76.8 97.5 116.5 143.1
    Refrigerant / R22
    Power Supply Type / 3PH-380V-50HZ
    Safety Protection Device / Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc
    Compressor Power KW 2.25 3.75 3*2 3.75*2 7.5+3.75 7.5*2 9.4*2 7.5*3 7.5*4 9*4 7.5*6
    Current A 4.8 9.2 15.2 17.2 41.3 36 50 54 66 80 99
    Pump Flow m³/h 4 4 8 8 12 16 20 36 36 36 36
    Phead m 22 22 27 27 31 33 21 20 20 20 20
    Power KW 0.55 0.55 1.1 1.3 1.85 2.6 2.2 4 4 4 4
    Condenser Type / MCHE Or Finned Tubes
    Air Flow m³/h 3000 5000 8000 10000 15000 20000 25000 30000 40000 50000 60000
    Fan Power KW 0.24 0.4 0.64 0.8 1.2 1.6 2 2.4 3.2 3.8 4
    Evaporator Type / Submerged Coil Type Dny Shell And Tube Type
    In/Out Pipe Size Inch DN25 DN25 DN40 DN50 DN50 DN50 DN65 DN65 DN80 DN80 DN80
    Tank Volume L 45 50 110 110 200 260 310 220 255 280 350
    Size Length mm 960 1050 1480 1480 1880 2000 2000 2400 2100 2450 3400
    Width mm 560 610 720 720 800 900 1000 1100 1600 1750 1800
    Height mm 1250 1300 1550 1550 1700 1800 1950 1950 1850 2050 2100
    Products Detail
    air cooled water chiller
    industrial water chiller
    Water chiller
    Frequently Asked Questions
    Q What is the main difference between an air-cooled chiller and a water-cooled chiller?
    The fundamental difference lies in how the condenser rejects heat. An air-cooled chiller uses ambient air forced across finned coil arrays by axial fans to dissipate heat, requiring no cooling tower or additional water supply. A water-cooled chiller uses a water circuit and cooling tower to reject heat, making it more efficient but more complex to install and maintain.
    Q What refrigerant is used in these air-cooled water chillers?
    All models in the SC series use R22 refrigerant. The system operates on a standard vapor-compression refrigeration cycle, with the refrigerant cycling through the evaporator, compressor, condenser, and expansion valve.
    Q What power supply is required for these chillers?
    All models in the SC series require a 3-phase power supply at 380V, 50Hz (3PH-380V-50HZ). Please ensure your facility's electrical infrastructure meets this requirement before installation.
    Q What safety protection features are built into the chiller?
    The chillers are equipped with comprehensive safety protection including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. The fault display system allows maintenance to be performed without requiring specialized professional personnel.
    Q Can the chiller be integrated into an automated management system?
    Yes. The chillers optionally support RS485 communication, enabling integration with building management systems (BMS) or factory automation platforms for remote monitoring and automatic management. The control mode can also be configured with an imported microcomputer or PLC control system (optional).
    Q How much energy can these chillers save compared to conventional systems?
    Thanks to the high-efficiency evaporator and condenser design, these chillers can save energy by more than 30% compared to conventional systems. The use of imported compressors and advanced components also contributes to long service life and reduced operating costs.