0102030405
China Suppliers Combined Heating and Cooling Machine - Efficient Thermal Circulator from Top Factory
Product Description
Temperature Range
-50℃ - 300℃
Power Range
Heating 6KW-96KW | Cooling 3KW-200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability.
Cooling Part
- Using brand scroll compressor, grain wheel, sanyo, daikin,etc
- The internal copper pipe is welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories Perfect safety
Core Working Principle
Its operation is based on a closed-loop circulation system:
1
Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
2
Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
3
Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
4
Temperature Regulation:
When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
5
Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
- 1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
- 2. Broad Temperature Control Range: A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
- 3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
-
4. High Efficiency and Energy Saving:
• Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.• Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
- 5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
Chemical & Pharmaceutical
Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
Plastics & Rubber
Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
Laboratory & Testing
Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
New Energy
Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
Semiconductor & Electronics
Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
Food Industry
Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
Other Industries
Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m3/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size(LxWxH) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions
What is the overall temperature control range of this equipment?
The unit supports a broad overall temperature range from -50℃ to 300℃, depending on the model specification and heat transfer medium (oil or water).
Which heat transfer media can be used in this system?
The system can utilize water, glycol-water mixtures, or thermal conductive oil as circulating media based on process temperature requirements.
How does the unit achieve high-precision temperature stabilization?
It uses PLC/PID intelligent control logic to real-time monitor temperature return feedback, dynamically toggling or modulating heating and cooling to maintain accurate stability within ±1°C or better.
What safety and fault detection features are integrated into the machine?
Built-in protections include alarms and safeguards for pump reversal, oil shortage, overheating, electrical overload, oil overflow, and abnormal heating display systems.
Why choose a combined heating and cooling unit over separate systems?
An integrated system saves valuable floor space, simplifies piping installation, improves energy management, and enables rapid alternating temperature cycles.