Introducing our advanced hot and cold unit, designed for precise temperature control in various applications. This thermal circulator is a cutting-edge solution that integrates refrigeration and heating functions into a single, efficient system. Ideal for laboratories and industrial processes, it expertly manages the temperature of reactors, instruments, and testing chambers. As a reliable supplier from China, our factory ensures the highest quality standards, making this thermal circulator an essential tool for temperature management in any professional setting. Optimize your operations with our innovative temperature control solution today!

    Product Description

    Temperature Range
    -50℃ - 300℃
    Power Range
    Heating 6KW-96KW | Cooling 3KW-200KW

    Basic Functions

    Heating Part
    • Return oil temperature display
    • Start up automatic exhaust
    • Heating power gear adjustment
    • Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
    • Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
    • PLC control, high reliability, strong anti-interference ability.
    Cooling Part
    • Using brand scroll compressor, grain wheel, sanyo, daikin,etc
    • The internal copper pipe is welded without oxygen
    • High efficiency evaporator and condenser
    • 304 SS stainless steel water tank
    • PC board self-optimized microprocessor, easy to operate
    • OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories Perfect safety

    Core Working Principle

    Its operation is based on a closed-loop circulation system:
    1
    Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
    2
    Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
    3
    Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
    4
    Temperature Regulation:
    When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
    5
    Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
    Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages

    • 1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
    • 2. Broad Temperature Control Range: A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
    • 3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
    • 4. High Efficiency and Energy Saving:
      • Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.
      • Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
    • 5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields

    Chemical & Pharmaceutical
    Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    Plastics & Rubber
    Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    Laboratory & Testing
    Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    New Energy
    Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    Semiconductor & Electronics
    Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    Food Industry
    Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
    Other Industries
    Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
    16
    15
    14

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter UNIT MODEL
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃-300℃ 5℃-120℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dny Shell And Tube Type
    Condenser type / MCHE Or Finned Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m3/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size(LxWxH) mm 1200*1100*1250 1450*1250*1550 1200*1000*1250 1300*1180*1400 1200*1050*1250 1450*1200*1550 1200*950*1250 1300*1130*1400

    Products Detail

    Combined Heating and Cooling Machine01
    Combined Heating and Cooling Machine 02
    Combined Heating and Cooling Machine 03

    Frequently Asked Questions

    What is the overall temperature control range of this equipment?
    The unit supports a broad overall temperature range from -50℃ to 300℃, depending on the model specification and heat transfer medium (oil or water).
    Which heat transfer media can be used in this system?
    The system can utilize water, glycol-water mixtures, or thermal conductive oil as circulating media based on process temperature requirements.
    How does the unit achieve high-precision temperature stabilization?
    It uses PLC/PID intelligent control logic to real-time monitor temperature return feedback, dynamically toggling or modulating heating and cooling to maintain accurate stability within ±1°C or better.
    What safety and fault detection features are integrated into the machine?
    Built-in protections include alarms and safeguards for pump reversal, oil shortage, overheating, electrical overload, oil overflow, and abnormal heating display systems.
    Why choose a combined heating and cooling unit over separate systems?
    An integrated system saves valuable floor space, simplifies piping installation, improves energy management, and enables rapid alternating temperature cycles.