China Suppliers and Factory for Combined Heating and Cooling Machines for Precise Temperature Control
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system — no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability
- Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- Internal copper pipe welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- Premium brand accessories: OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and more
-
1Circulating Medium
The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
-
2Pumping
A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
-
3Heat Exchange
The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
-
4Temperature Regulation
When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
-
5Return and Feedback
The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
A single unit covers a wide span: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, or 0°C to +300°C.
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
Full-capacity cooling for fast results. During stabilization, the system runs at lower power to offset process heat. Advanced models can recover waste heat from the refrigeration system for pre-heating.
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
- ⚗️ Chemical & Pharmaceutical Precise temperature control for reaction kettles, distillation condensation, bioreactor/fermenter control, GMP process temperature control.
- 🔩 Plastics & Rubber Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold, extruder roller temperature control.
- 🔬 Laboratory & Testing Cooling for rotary evaporators, reaction calorimeters, bioreactors; supporting environmental test chambers; material high/low-temperature testing.
- 🔋 New Energy Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
- 💻 Semiconductor & Electronics Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
- 🍫 Food Industry Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
- 🏭 Other Industries Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃–300℃ | 5℃–120℃ | ||||||
| Temp control accuracy | ℃ | PID ±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200×1100×1250 | 1450×1250×1550 | 1200×1000×1250 | 1300×1180×1400 | 1200×1050×1250 | 1450×1200×1550 | 1200×950×1250 | 1300×1130×1400 |