0102030405
China Suppliers and Factory for Combined Heating and Cooling Machine – Precision Temperature Control Solution
Product Description
Temperature Range: -50℃ ~ 300℃
Heating Power: 6KW – 96KW
Cooling Power: 3KW – 200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- 304 stainless steel integrated pipe — reduces pipe resistance and carbon deposition
- Perfect safety protection & fault display system — no professional personnel needed for repair
- PLC control — high reliability, strong anti-interference ability
Cooling Part
- Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- Internal copper pipe welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor — easy to operate
- Premium brand accessories: OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and more
Core Working Principle
Its operation is based on a closed-loop circulation system:
- 1. Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
- 2. Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
- 3. Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
-
4. Temperature Regulation:
- When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
- When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
- 5. Return and Feedback: The fluid returns to the unit and passes a temperature sensor. The PID control system compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling — ensuring output fluid temperature remains constant within ±0.1°C or better.
⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features & Advantages
-
🏗️
1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
-
🌡️
2. Broad Temperature Control Range: A single unit covers a wide span from low to high temperatures. Common ranges: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
-
🎯
3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
-
⚡
4. High Efficiency and Energy Saving:
- Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at lower power to offset it — more efficient than cooling alone.
- Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
-
🚀
5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
⚗️ Chemical & Pharmaceutical
Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
🔩 Plastics & Rubber
Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
🔬 Laboratory & Testing
Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
🔋 New Energy
Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
💻 Semiconductor & Electronics
Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
🍫 Food Industry
Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
🏭 Other Industries
Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200*1100*1250 | 1450*1250*1550 | 1200*1000*1250 | 1300*1180*1400 | 1200*1050*1250 | 1450*1200*1550 | 1200*950*1250 | 1300*1130*1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q What is the temperature control range of this combined heating and cooling machine?
The unit supports a temperature range of -50°C to 300°C. Specific models cover ranges such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C, making it suitable for both low-temperature and high-temperature industrial processes.
Q What heat transfer media can this unit use?
Depending on the model, the unit supports thermo conductive oil (for high-temperature oil models, 5°C–300°C) or water (for water models, 5°C–120°C). Some configurations also support glycol-water mixtures for sub-zero applications.
Q How precise is the temperature control?
The system uses PID intelligent control with a standard accuracy of ±1°C. Advanced configurations can achieve ±0.1°C or better, making it ideal for precision processes in pharmaceuticals, semiconductors, and laboratory environments.
Q What industries is this machine suitable for?
This combined heating and cooling unit is widely applied across chemical & pharmaceutical, plastics & rubber, laboratory & testing, new energy (battery testing), semiconductor & electronics, food industry, and other manufacturing sectors requiring precise temperature management.
Q Does the unit have built-in safety protection features?
Yes. The machine is equipped with a comprehensive alarm and protection system covering: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The PLC-based control system ensures high reliability with strong anti-interference capability, requiring no specialized personnel for routine maintenance.
Q What is the power supply requirement and available heating/cooling capacity?
All models operate on AC 380V / 50Hz. Heating power ranges from 6KW to 96KW, and cooling capacity ranges from 3KW to 200KW, covering a broad spectrum of industrial load requirements.