China Suppliers Air Cooled Water Chiller – Efficient Cooling Solutions from Trusted Factory
Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Working Principle and System Components
1
Refrigeration Cycle (consistent with all compression refrigeration systems)
- Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
- The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
- The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
- The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
2
Core Difference — The Air-Cooled Condenser
- This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
- The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
3
System Composition (Highly Integrated)
- Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
- Auxiliary Components:
- Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
- Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
- Electrical Control Cabinet: Integrates control, protection, and display functions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍶
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||||||
| SC-03AS | SC-05AS | SC-08AS | SC-10AD | SC-15AD | SC-20AD | SC-25AD | SC-30AD | SC-40AD | SC-50AD | SC-60AD | |||
| Cooling Capacity | Kcal/h | 7216 | 11990 | 18748 | 24089 | 37965 | 50808.8 | 61683 | 74992 | 97678 | 116521 | 156249 | |
| KW | 8.39 | 13.95 | 21.8 | 28.01 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | ||
| Power Input | KW | 3.6 | 5.5 | 8.6 | 11 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
| Running Current | A | 8.8 | 13.4 | 20.9 | 26.7 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
| Refrigerant | / | R22 | |||||||||||
| Power Supply Type | / | 3PH-380V-50HZ | |||||||||||
| Safety Protection Device | / | Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc | |||||||||||
| Compressor | Power | KW | 2.25 | 3.75 | 3*2 | 3.75*2 | 7.5+3.75 | 7.5*2 | 9.4*2 | 7.5*3 | 7.5*4 | 9*4 | 7.5*6 |
| Current | A | 4.8 | 9.2 | 15.2 | 17.2 | 41.3 | 36 | 50 | 54 | 66 | 80 | 99 | |
| Pump | Flow | m³/h | 4 | 4 | 8 | 8 | 12 | 16 | 20 | 36 | 36 | 36 | 36 |
| Phead | m | 22 | 22 | 27 | 27 | 31 | 33 | 21 | 20 | 20 | 20 | 20 | |
| Power | KW | 0.55 | 0.55 | 1.1 | 1.3 | 1.85 | 2.6 | 2.2 | 4 | 4 | 4 | 4 | |
| Condenser | Type | / | MCHE Or Finned Tubes | ||||||||||
| Air Flow | m³/h | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
| Fan Power | KW | 0.24 | 0.4 | 0.64 | 0.8 | 1.2 | 1.6 | 2 | 2.4 | 3.2 | 3.8 | 4 | |
| Evaporator | Type | / | Submerged Coil Type | Dny Shell And Tube Type | |||||||||
| In/Out Pipe Size | Inch | DN25 | DN25 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | |
| Tank Volume | L | 45 | 50 | 110 | 110 | 200 | 260 | 310 | 220 | 255 | 280 | 350 | |
| Size | Length | mm | 960 | 1050 | 1480 | 1480 | 1880 | 2000 | 2000 | 2400 | 2100 | 2450 | 3400 |
| Width | mm | 560 | 610 | 720 | 720 | 800 | 900 | 1000 | 1100 | 1600 | 1750 | 1800 | |
| Height | mm | 1250 | 1300 | 1550 | 1550 | 1700 | 1800 | 1950 | 1950 | 1850 | 2050 | 2100 | |
Products Detail
Frequently Asked Questions
Q
What is the difference between an air-cooled chiller and a water-cooled chiller?
The core difference lies in the condenser type. An air-cooled chiller uses ambient air forced across finned coil arrays by axial fans to dissipate heat, requiring no cooling tower or external water supply. A water-cooled chiller relies on a cooling tower and circulating water to remove heat from the condenser, making it more suitable for large-scale indoor installations. Air-cooled chillers offer simpler installation, lower maintenance, and greater flexibility for outdoor or space-limited environments.
Q
What refrigerant is used in these air-cooled water chillers?
All models in the SC series use R22 refrigerant as standard. R22 provides stable performance across a wide range of operating conditions and is well-suited for industrial cooling applications. Please consult with our technical team if alternative refrigerant options are required for specific regional compliance standards.
Q
What power supply is required to operate these chillers?
All models operate on a standard 3-phase power supply: 3PH – 380V – 50Hz. This is the industrial standard in most regions. If your facility uses a different voltage or frequency, please contact us to discuss customized electrical configurations before ordering.
Q
What safety protection features are built into the chiller?
The SC series chillers are equipped with a comprehensive safety protection system, including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. These features ensure stable operation, minimize downtime, and allow maintenance to be performed without requiring specialized professional personnel.
Q
Can the chiller be integrated into an automated production management system?
Yes. The chillers support RS485 communication as an optional feature, enabling seamless integration with factory automation and building management systems (BMS). Additionally, the control mode can be configured with an imported microcomputer controller or PLC control system (optional), providing flexible and intelligent management of the cooling process.
Q
How much energy can the high-efficiency evaporator and condenser save?
The SC series is designed with high-efficiency evaporators and condensers that can achieve energy savings of more than 30% compared to conventional chiller designs. This is achieved through optimized heat transfer surfaces, oxygen-free copper pipe welding, and the use of imported high-performance components, resulting in significantly reduced operating costs over the equipment's service life.