0102030405
China Oil Temperature Controller Suppliers | Factory Direct Mold Temperature Machine for Precision Heating
Machine Features
- Return oil temperature display
- Heating power gear adjustment
- Start up automatic exhaust
- PC board self-optimization microprocessor, PID automatic adjustment, simple operation
- By-pass pressure relief loop for hot oil
- The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
- Imported electrical accessories: WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
- Perfect safety protection and fault display system
- Professional personnel needed for repair and maintenance
⚙ Optional Features
- Multi-point temperature control unit can be customized professionally
- RS485 communication for automatic management
- PLC control, high reliability, strong anti-interference ability
- Time switch machine, cooling shut down function
- Blow back function
- Explosion-proof design of electric control cabinet and pipeline
Core Working Principle and System Composition
Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium.
1 Operating Cycle
High-Temperature Media Circulation
A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
High-Temperature Heat Output
The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
Oil Return & Temperature Control
After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
2 Core System Components (Enhanced Design)
High-Temperature Heating System
- Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
- Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
- High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
High-Temperature Control System
- Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
- Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
Safety & Auxiliary Systems (Critical)
- Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
Auxiliary Components
- Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
- Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
- Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
| Temp control range | ℃ | Inlet water temperature +45℃–180℃ | ||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Thermo conductive oil | ||||
| Cooling method | / | Indirect Cooling | ||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m³/h | 6 | 6 | 10 | 14 | 16 |
| Pump head | m | 18 | 18 | 20 | 18 | 20 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Expansion tank capacity | L | 20 | 20 | 20 | 30 | 50 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating oil pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size (L×W×H) | mm | 850×325×700 | 850×325×700 | 850×325×700 | 1170×450×950 | 1500×500×1100 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the maximum operating temperature of this thermal oil temperature control unit?
This thermal oil temperature control unit supports a temperature control range from inlet water temperature +45°C up to 180°C (standard models). With the appropriate thermal oil selection and system configuration, operating temperatures of up to 350°C or higher can be achieved, making it suitable for high-temperature industrial processes.
Q
What type of heat transfer fluid is used, and how should it be selected?
The unit uses thermal oil (thermo conductive oil) as the heat transfer medium. The appropriate oil grade should be selected based on the maximum operating temperature, required thermal stability, and safety characteristics of your application. Common models include L-QB and L-QC series thermal oils. Please consult our technical team for specific recommendations.
Q
What safety protection features are built into the system?
The unit is equipped with a comprehensive multi-layer safety protection system, including: multiple over-temperature protections (with a mechanical thermostat independent of the main controller), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss and reverse phase protection, as well as alarm functions for pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating.
Q
Can the unit be integrated with factory automation or remote monitoring systems?
Yes. The unit supports optional RS485 communication for automatic management and remote monitoring integration. Additionally, optional PLC control is available for high reliability and strong anti-interference capability, enabling seamless integration into modern automated production environments.
Q
Is a cooling function available, and how does it work?
Yes, a cooling system is available as an optional but commonly integrated feature. It uses an indirect cooling method via an integrated oil/water heat exchanger or oil/air cooler. This enables rapid cool-down after process completion or assists in temperature control during processes that require cooling phases. The cooling water pipe connection is 1/2 inch across all standard models.
Q
Which model should I choose based on my heating power requirements?
There are five standard models available — SOS-05, SOS-10, SOS-20, SOS-30, and SOS-40 — with heating power ranging from 6 KW to 36 KW and total power input from 6.33 KW to 39 KW. Selection should be based on your required heating capacity, pump flow rate, and installation space. For customized multi-point temperature control solutions, please contact our engineering team directly.