China Oil Temperature Controller for Molds - Reliable Suppliers & Factory Solution for Precision Heating
- Return oil temperature display
- Heating power gear adjustment
- Start up automatic exhaust
- PC board self-optimization microprocessor, PID automatic adjustment, simple operation
- By-pass pressure relief loop for hot oil
- The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
- Imported electrical accessories: WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
- Perfect safety protection and fault display system
- Professional personnel needed for repair and maintenance
- Multi-point temperature control unit can be customized professionally
- RS485 communication for automatic management
- PLC control, high reliability, strong anti-interference ability
- Time switch machine, cooling shut down function
- Blow back function
- Explosion-proof design of electric control cabinet and pipeline
Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium.
A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
- Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
- Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
- High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
- Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
- Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
- Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
- Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
- Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
- Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
| Temp control range | ℃ | Inlet water temperature +45℃–180℃ | ||||
| Temp control accuracy | ℃ | PID ±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Thermo conductive oil | ||||
| Cooling method | / | Indirect Cooling | ||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m³/h | 6 | 6 | 10 | 14 | 16 |
| Pump head | m | 18 | 18 | 20 | 18 | 20 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Expansion tank capacity | L | 20 | 20 | 20 | 30 | 50 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating oil pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size (L×W×H) | mm | 850×325×700 | 850×325×700 | 850×325×700 | 1170×450×950 | 1500×500×1100 |