China Oil Temperature Controller Factory - Reliable Suppliers of Mold Temperature Machines for Various Industries

The Oil Temperature Machine is an advanced mold temperature controller that utilizes heat-conducting oil as its medium. Often referred to as an oil heater, oil temperature heater, or oil circulation temperature controller, this device is essential for precise temperature management in various industries. With an impressive maximum temperature capacity of 300℃, it provides easy operation and reliable performance, This versatile oil temperature controller is widely utilized in applications such as hot pressing dies, laminating machines, FRP production, automotive interior parts, carbon fiber processing, composite materials, and in the plastic and rubber industries. As one of the leading China suppliers and factories, we ensure that our oil temperature machines meet the highest quality standards while delivering optimal efficiency in thermal management for your production needs

    Machine Future
    • Return oil temperature display
    • Heating power gear adjustment
    • Start up automatic exhaust
    • PC board self-optimization microprocessor, PID automatic adjustment, simple operation
    • By-pass pressure relief loop for hot oil
    • The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
    • Imported electrical accessories: WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
    • Perfect safety protection and fault display system
    • Professional personnel needed for repair and maintenance
    ⚙ Optional Features
    • Multi-point temperature control unit can be customized professionally
    • RS485 communication for automatic management
    • PLC control, high reliability, strong anti-interference ability
    • Time switch machine, cooling shut down function
    • Blow back function
    • Explosion-proof design of electric control cabinet and pipeline
    Core Working Principle and System Composition

    Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium.

    1 Operating Cycle
    High-Temperature Media Circulation

    A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).

    High-Temperature Heat Output

    The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.

    Oil Return & Temperature Control

    After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.

    2 Core System Components (Enhanced Design)
    High-Temperature Heating System
    • Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
    • Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
    • High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
    High-Temperature Control System
    • Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
    • Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
    🛡️Safety & Auxiliary Systems (Critical)
    Safety Protections:
    • Multiple over-temperature protections (mechanical thermostat independent of main control)
    • Low fluid level protection
    • Pump overload protection
    • Abnormal pressure protection
    • Phase loss / reverse phase protection
    Auxiliary Components:
    • Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
    • Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
    • Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
    Industrial Applications
    Industrial Application 1
    Industrial Application 2
    Industrial Application 3
    Flowchart
    Flowchart
    Specification
    Parameter UNIT MODEL
    SOS-05 SOS-10 SOS-20 SOS-30 SOS-40
    Temp control range ℃ Inlet water temperature +45℃–180℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m³/h 6 6 10 14 16
    Pump head m 18 18 20 18 20
    Power Input KW 6.33 9.75 13.5 26.2 39
    Expansion tank capacity L 20 20 20 30 50
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size (L×W×H) mm 850×325×700 850×325×700 850×325×700 1170×450×950 1500×500×1100
    Products Detail
    HG9A2109
    HG9A2110
    HG9A2117
    Frequently Asked Questions (FAQ)
    Q What is the maximum operating temperature of this thermal oil temperature control unit?
    This unit supports a temperature control range from inlet water temperature +45°C up to 180°C, with PID precision control accuracy of ±1°C. The high-temperature heating system can handle thermal oil heated up to 350°C or higher depending on the selected heat transfer fluid and model configuration.
    Q What type of heat transfer fluid (thermal oil) should be used with this unit?
    The unit uses thermo-conductive oil as the heat transfer medium. The specific thermal oil grade should be selected based on the maximum operating temperature, thermal stability requirements, and safety considerations. Commonly used grades include L-QB and L-QC. Please consult the manufacturer for the most suitable oil specification for your application.
    Q What safety protection features does the unit include?
    The unit is equipped with a comprehensive safety protection and fault display system, including: pump reversal protection, oil shortage alarm, overheating protection (with independent mechanical thermostat), overload protection, oil overflow alarm, abnormal heating alarm, low fluid level protection, abnormal pressure protection, and phase loss/reverse phase protection.
    Q Can the unit be integrated into an automated production management system?
    Yes. The unit offers optional RS485 communication for automatic management and PLC control with high reliability and strong anti-interference ability. These features allow seamless integration into automated production lines and remote monitoring systems for centralized management.
    Q What are the typical industrial applications for this thermal oil temperature control unit?
    This unit is widely used in industries requiring precise high-temperature process control, including plastic injection molding (high-temperature molds), rubber vulcanization, chemical reactor heating (jacket heating), composite material pressing, laminating machines, and other applications involving platens, molds, or reactors that require stable and accurate high-temperature heat supply.
    Q What are the power supply requirements, and which models are available?
    All models operate on AC 380V, 50Hz power supply. Five standard models are available — SOS-05, SOS-10, SOS-20, SOS-30, and SOS-40 — with heating power ranging from 6 KW to 36 KW and pump flow rates from 6 m³/h to 16 m³/h, suitable for a wide range of industrial process scales.