0102030405
China Oil Temperature Controller Factory | High-Quality Oil Mold Temperature Machine from Reliable Suppliers
Machine Future
Return oil temperature display
Heating power gear adjustment
Start up automatic exhaust
PC board self-optimization microprocessor, PID automatic adjustment, simple
By-pass pressure relief loop for hot oil
The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
Imported electrical accessories, WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
Perfect safety protection and fault display system
Professional personnel needed for repair and maintenance
Optional Features:
Multi-point temperature control unit can be customized professionally
RS485 communication for automatic management
PLC control, high reliability, strong anti-interference ability
Time switch machine, cooling shut down function
Blow back function
Explosion-proof design of electric control cabinet and pipeline
Core Working Principle and System Composition
Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium:
1. Operating Cycle:
- High-Temperature Media Circulation: A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).
- High-Temperature Heat Output: The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.
- Oil Return & Temperature Control: After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.
2. Core System Components (Enhanced Design):
High-Temperature Heating System:
- Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
- Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
- High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
High-Temperature Control System:
- Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
- Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
Safety & Auxiliary Systems (Critical):
- Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
-
Auxiliary Components:
- Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
- Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
- Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.
Industrial Applications
Flowchart
Specification
| Parameter | UNIT | MODEL | ||||
| SOS-05 | SOS-10 | SOS-20 | SOS-30 | SOS-40 | ||
| Temp control range | ℃ | Inlet water temperature +45℃-180℃ | ||||
| Temp control accuracy | ℃ | PID±1℃ | ||||
| Power supply | / | AC380V 50Hz | ||||
| Heat transfer medium | / | Thermo conductive oil | ||||
| Cooling method | / | Indirect Cooling | ||||
| Alarm function | / | Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating | ||||
| Heating power | KW | 06 | 09 | 12 | 24 | 36 |
| Motor power | KW | 0.33 | 0.75 | 1.5 | 2.2 | 3 |
| Pump flow | m3/h | 6 | 6 | 10 | 14 | 16 |
| Pump head | m | 18 | 18 | 20 | 18 | 20 |
| Power Input | KW | 6.33 | 9.75 | 13.5 | 26.2 | 39 |
| Expansion tank capacity | L | 20 | 20 | 20 | 30 | 50 |
| Cooling water pipe | Inch | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
| Circulating oil pipe | Inch | 3/4" | 1" | 1" | 1-1/4" | 1-1/2" |
| Size(LxWxH) | mm | 850*325*700 | 850*325*700 | 850*325*700 | 1170*450*950 | 1500*500*1100 |
Products Detail
Frequently Asked Questions
What is the temperature control range of this oil temperature control unit?
The temperature control range of this unit is from the inlet water temperature +45℃ up to 180℃, with a precise PID control accuracy of ±1℃.
What safety and alarm protections are built into the system?
The system features comprehensive safety protection and alarms, including pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating indicators.
Why does the system utilize an expansion tank?
The overhead expansion tank is directly connected to the system to safely compensate for the thermal expansion and contraction of the heat transfer oil, vent vapors, and act as an oil reservoir.
Can I customize the control system for automated industrial integration?
Yes, optional features include RS485 communication for automatic management systems, PLC control for high reliability and anti-interference, and customizable multi-point temperature control units.
How does the cooling system function in this thermal oil unit?
The unit utilizes an indirect cooling method, commonly employing an integrated oil/water heat exchanger or oil/air cooler to achieve rapid cool-down periods after process completion.
What is the purpose of the isolated electric cabinet design?
The electric cabinet is physically isolated from the main fuselage to provide optimal thermal insulation, protecting the imported electrical accessories (such as Siemens, ABB, Schneider) from high operating heat and extending their service life.