Leave Your Message

China Oil Temperature Controller Factory - High-Precision Mold Temperature Machine Suppliers for Various Industries

The Oil Temperature Machine is a highly efficient mold temperature control solution utilizing heat-conducting oil as its medium. Also known as an oil heater, oil temperature controller, or oil circulation temperature controller, this device offers precise temperature management, making it easy to operate with a maximum temperature capability of 300℃, Manufactured in China, this product is ideal for various applications, including hot pressing dies, laminating machines, FRP production, automotive interior parts, carbon fiber manufacturing, as well as in the plastic and rubber industries. Trusted by global suppliers, our factory produces high-quality oil temperature machines that are essential for processes involving clenders, coater rollers, and kneaders. Upgrade your production efficiency with our reliable oil temperature controller solutions today!

    Machine Future

    • Return oil temperature display
    • Heating power gear adjustment
    • Start up automatic exhaust
    • PC board self-optimization microprocessor, PID automatic adjustment, simple operation
    • By-pass pressure relief loop for hot oil
    • The electric cabinet is isolated from the fuselage, with good thermal insulation effect and long service life of the appliances
    • Imported electrical accessories — WEST, ABB, CARLO, LS, SCHNEIDER, SIEMENS, OMRON, etc.
    • Perfect safety protection and fault display system
    • Professional personnel needed for repair and maintenance
    • Optional Multi-point temperature control unit can be customized professionally
    • Optional RS485 communication for automatic management
    • Optional PLC control, high reliability, strong anti-interference ability
    • Optional Time switch machine, cooling shut down function
    • Optional Blow back function
    • Optional Explosion-proof design of electric control cabinet and pipeline

    Core Working Principle and System Composition

    💡 Its operational principle is similar to that of a water temperature control unit, as both are closed-loop heating systems. However, key differences exist due to the distinct heat transfer medium.
    1 Operating Cycle

    High-Temperature Media Circulation: A high-temperature circulation pump draws thermal oil from the storage tank or system and pumps it into the high-temperature heater (e.g., flanged electric heating tubes), where it is heated to the set high temperature (up to 350°C or higher).

    High-Temperature Heat Output: The high-temperature thermal oil is delivered to the user end (e.g., high-temperature mold, platen, reactor jacket) for efficient heat exchange.

    Oil Return & Temperature Control: After releasing heat, the thermal oil returns to the unit, passes through an oil filter, and re-enters the heating cycle. A high-temperature PID temperature controller achieves precise temperature control at elevated levels (accuracy up to ±0.5~1°C) by accurately regulating heater activation/deactivation or power output.

    2 Core System Components (Enhanced Design)
    🔧 High-Temperature Heating System
    • Heater: Utilizes flanged electric heating tubes that are high-temperature resistant and dry-fire protected, featuring high power density and typically integrated into a pressure-resistant heating cylinder.
    • Heat Transfer Fluid: Thermal oil, selected based on maximum operating temperature, thermal stability, and safety (e.g., models like L-QB, L-QC).
    • High-Temperature Power System: High-temperature, corrosion-resistant coupling pumps or special mechanical seal pumps capable of providing stable, high flow rates under high-temperature, low-viscosity conditions.
    🎛️ High-Temperature Control System
    • Core: A PID temperature controller designed for high-temperature environments, featuring more complex control algorithms.
    • Key Components: High-power contactors or SCR power controllers, Type K or S thermocouples (for high-temperature measurement), pressure sensors.
    🛡️ Safety & Auxiliary Systems (Critical)
    • Safety Protections: Multiple over-temperature protections (mechanical thermostat independent of main control), low fluid level protection, pump overload protection, abnormal pressure protection, phase loss/reverse phase protection.
    • Expansion Tank (Overhead Tank): Directly connected to the system, used to compensate for thermal expansion/contraction of the oil, vent vapors, and serve as a safety oil reservoir.
    • Cooling System (Optional but Common): Integrated oil/water heat exchanger or oil/air cooler for rapid cool down after process completion or to assist in temperature control during processes requiring cooling phases.
    • Precision Filter: Removes carbon deposits and impurities from the thermal oil, protecting the pump and heater.

    Industrial Applications

    Industrial Application 1
    Industrial Application 2
    Industrial Application 3

    Flowchart

    Flowchart

    Specification

    Parameter UNIT MODEL
    SOS-05 SOS-10 SOS-20 SOS-30 SOS-40
    Temp control range ℃ Inlet water temperature +45℃–180℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil
    Cooling method / Indirect Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Heating power KW 06 09 12 24 36
    Motor power KW 0.33 0.75 1.5 2.2 3
    Pump flow m³/h 6 6 10 14 16
    Pump head m 18 18 20 18 20
    Power Input KW 6.33 9.75 13.5 26.2 39
    Expansion tank capacity L 20 20 20 30 50
    Cooling water pipe Inch 1/2" 1/2" 1/2" 1/2" 1/2"
    Circulating oil pipe Inch 3/4" 1" 1" 1-1/4" 1-1/2"
    Size (L×W×H) mm 850×325×700 850×325×700 850×325×700 1170×450×950 1500×500×1100

    Products Detail

    HG9A2109
    HG9A2110
    HG9A2117

    Frequently Asked Questions

    ❓ What is the maximum operating temperature of the thermal oil temperature control unit?
    The thermal oil temperature control unit supports a temperature control range from inlet water temperature +45°C up to 180°C (with high-temperature models capable of reaching 350°C or higher depending on the thermal oil selected). PID control ensures accuracy of ±1°C.
    ❓ What type of heat transfer fluid is used in this system?
    The system uses thermo conductive oil (thermal oil) as the heat transfer medium. The specific grade is selected based on the maximum operating temperature, thermal stability, and safety requirements — common options include L-QB and L-QC series thermal oils.
    ❓ What safety protection features are built into the unit?
    The unit is equipped with a comprehensive safety protection system including: pump reversal alarm, oil shortage alarm, overheating protection, overload protection, oil overflow alarm, abnormal heating alarm, phase loss/reverse phase protection, and independent mechanical thermostat over-temperature protection — ensuring safe and reliable operation.
    ❓ Can the unit be integrated with automation or PLC systems?
    Yes. As an optional feature, the unit supports RS485 communication for automatic management and PLC control with high reliability and strong anti-interference ability. This allows seamless integration into automated production lines and remote monitoring systems.
    ❓ What are the available heating power options and how do I choose the right model?
    Heating power ranges from 6 KW (SOS-05) to 36 KW (SOS-40). Selection depends on your application's heat load requirements, mold or equipment size, and required temperature ramp-up speed. Please refer to the specification table for detailed pump flow, pump head, and power input data for each model.
    ❓ What industries and applications is this thermal oil temperature control unit suitable for?
    This unit is widely used in industries such as rubber and plastics processing, chemical and pharmaceutical manufacturing, food processing, printing and laminating, composite materials production, and any application requiring precise high-temperature control — including high-temperature molds, platens, reactor jackets, and calendering rollers.