0102030405
China Industrial Water Cooled Screw Chiller - Top Suppliers and Reliable Factory Solutions
Machine Future
- Temperature Range: -80℃ ~ 35℃
- Power Range: Cooling Power 100KW – 1500KW
- Compressor: High efficiency imported high quality screw compressor, such as Hanbell, Bitzer, etc.
- Heat Exchanger: Shell and tube evaporator and condenser — high efficiency, stable operation
- Brand Accessories: OMRON, FUJI, TE, LG, ABB, SIEMENS and other brand accessories
- Safety System: Perfect safety protection and fault display system — no professional person needed for repair and maintenance
- Control: PLC control, high reliability, strong anti-interference ability; Explosion-proof design of electric control cabinet and pipeline
- Safety Features: High and low voltage protection, phase sequence protection, overload protection, medium liquid level monitoring, etc.
- Special Features: Remote communication function (TCP/RTU), Explosion-proof design
Core Features & Advantages
Compared to centrifugal and scroll compressors, screw compressors demonstrate irreplaceable advantages in industrial applications:
🔩 1. Outstanding Reliability and Durability
Robust Construction
The meshing movement of the twin screw rotors involves pure metal contact. With no reciprocating parts, wear is minimal, vibration is low, and service life is extended.
High Tolerance to Liquid Slugging
Insensitive to minor liquid flood-back, capable of adapting to rapid load changes — suitable for industrial sites with significant load fluctuations.
⚙️ 2. Wide-Ranging and Efficient Capacity Modulation
Continuous Modulation
Utilizing a sliding vane (slide valve) mechanism, it enables continuous capacity control from 10% to 100%, offering high efficiency at part-load conditions — ideal for matching the variable thermal loads of industrial production lines.
Excellent Start-Up Characteristics
Typically equipped with star-delta or soft starters, minimizing grid impact.
🌡️ 3. Superior Stability and Adaptability
Smooth Operation
Continuous compression ensures stable output and high precision in water temperature control.
Broad Refrigerant Compatibility
Suitable not only for conventional R134a and R410A but also for natural working fluids like Ammonia (R717) and Propane (R290), meeting special industrial requirements.
🛠️ 4. Ease of Maintenance
Fewer major moving parts result in longer maintenance intervals. Core components (e.g., bearings, shaft seals) can be serviced on-site without factory return, minimizing downtime.
Typical System Composition
A typical industrial water-cooled screw chiller features a system enhanced beyond standard configurations:
🔧 Core Four Components
1. Screw Compressor
Typically employs twin-screw, semi-hermetic, or open-type designs. Industrial units often feature multiple compressor circuits in parallel (e.g., 2, 3, or 4 compressors) for redundancy and finer capacity control.
2. Water-Cooled Shell-and-Tube Condenser
Utilizes high-efficiency heat transfer tubes for enhanced heat dissipation. Industrial designs incorporate a larger fouling factor allowance.
3. Dry-Expansion or Flooded Evaporator
- Dry-Expansion Evaporator: Commonly used for standard temperature ranges, easier to maintain.
- Flooded Evaporator: Offers higher heat transfer efficiency (typically 5–8% higher than dry-expansion), often used in large or high-efficiency units, but demands more sophisticated oil return design.
4. Expansion Device
Electronic Expansion Valves (EXV) are mainstream, providing precise control. Large units may use orifice plates or thermal expansion valve assemblies.
🏭 Industrial-Grade Auxiliary Systems
- High-Efficiency Oil Separator and Oil Management System: Multi-stage, high-efficiency oil separators ensure reliable oil return, which is critical for stable screw compressor operation.
- Enhanced Electrical Control System: Employs industrial-grade PLC controllers with comprehensive sensor monitoring (pressure, temperature, oil level, current), fault diagnostics, integration capabilities, and remote communication interfaces (Modbus, BACnet).
- Multi-Layer Protection System: Beyond basic protections, special emphasis is placed on oil pressure differential protection, oil temperature protection, and motor winding over-temperature protection.
🏗️ Primary Application Scenarios
Covers virtually all industrial sectors requiring stable, continuous, and high-capacity process cooling:
Application Industries
🏭 Industrial refrigeration | ❄️ Central air conditioning systems | 💻 Data centers | 🚢 Ship building industry
Schematic Diagram
Specification
| ITEM | UNIT | TCS-140WS | TCS-180WS | TCS-260WS | TCS-340WS | TCS-410WS | TCS-470WS | TCS-510WS | TCS-580WS | TCS-710WS | TCS-790WS | TCS-830WS | TCS-930WS | |
| Cooling Capacity | kcal/h | 103458 | 135794 | 197800 | 269524 | 321124 | 382184 | 403512 | 478504 | 5788608 | 746571 | 805141 | 298474 | |
| kW | 120.3 | 157.9 | 230 | 313.4 | 373.4 | 444.4 | 469.2 | 556.4 | 672.8 | 868 | 936 | 1045 | ||
| Total Power Input | kW | 28.5 | 36.1 | 52.4 | 67.7 | 83 | 96.4 | 101.7 | 118.7 | 142.5 | 157 | 167 | 185 | |
| Maximum Running Current | A | 91 | 121 | 171 | 220 | 268 | 310 | 336 | 377 | 453 | 498 | 534 | 620 | |
| Refrigerant | R22 / R407C | |||||||||||||
| Steps Control | % | 0/33/66/100 | 0/25/50/75/100 | |||||||||||
| Temperature Control Range | ℃ | +5 ~ +35 | ||||||||||||
| Control Type | Siemens PLC Automatic Control, Color LCD Touch Screen | |||||||||||||
| Power Supply Type | 3N, 380V, 50Hz | |||||||||||||
| Safety Protection Device | Overload, Inverse Phase, High/Low Pressure, Safety Valve, Water Flow, Oil Level, Exhaust Temperature, Antifreeze Protection, etc. | |||||||||||||
| Compressor | Type | / | Semi-hermetic Screw | |||||||||||
| Start Type | / | Y-△ | ||||||||||||
| Amount | Sets | 1 | ||||||||||||
| Condenser | Type | / | Shell And Tube Type | |||||||||||
| Water Flow | m³/h | 26 | 34 | 49 | 67 | 80 | 98 | 100 | 118 | 143 | 187 | 201 | 225 | |
| Water Pressure Drop | kPa | 95 | 95 | 98 | 35 | 35 | 35 | 35 | 35 | 35 | 95 | 95 | 95 | |
| In/Out Pipe Size | DN | 65 | 80 | 80 | 100 | 125 | 125 | 125 | 125 | 150 | 150 | 200 | 200 | |
| Evaporator | Type | / | Dry Shell And Tube Type | Flood Type | ||||||||||
| Water Flow | m³/h | 21 | 27 | 40 | 54 | 64 | 76 | 81 | 96 | 116 | 149 | 161 | 180 | |
| Water Pressure Drop | kPa | 85 | 85 | 85 | 32 | 32 | 32 | 32 | 32 | 32 | 90 | 90 | 90 | |
| In/Out Pipe Size | DN | 86 | 80 | 80 | 130 | 125 | 125 | 125 | 125 | 150 | 150 | 200 | 200 | |
| L×W×H | cm | 266*71*142 | 267*78*154 | 292*81*169 | 297*91*184 | 328*91*189 | 330*99*195 | 330*99*201 | 356*108*210 | 358*113*225 | 376*118*230 | 379*127*238 | ||
| Net Weight | kg | 970 | 1130 | 1460 | 1790 | 2060 | 2320 | 2490 | 2770 | 3310 | 3392 | 3050 | 2060 | |
| Refrigerant Charge | kg | 23 | 30 | 43 | 59 | 70 | 84 | 89 | 105 | 127 | 156 | 168 | 187 | |
* Specifications subject to change without prior notice. Please consult our technical team for the latest data.
Products Detail
Frequently Asked Questions (FAQ)
What is the cooling capacity range of your industrial water-cooled screw chiller?
Our industrial water-cooled screw chillers cover a cooling power range from 100KW to 1500KW, with temperature ranges from -80℃ to +35℃, making them suitable for a wide variety of industrial process cooling requirements.
What refrigerants are compatible with these screw chillers?
The units are compatible with R22, R407C, R134a, R410A, as well as natural refrigerants such as Ammonia (R717) and Propane (R290), providing flexibility to meet different environmental and industrial standards.
How is the capacity of the screw chiller controlled?
Capacity is controlled via a sliding vane (slide valve) mechanism, enabling continuous modulation from 10% to 100%. Step control options (0/25/50/75/100% or 0/33/66/100%) are also available depending on the model, ensuring efficient operation under varying load conditions.
What safety protection features are included?
The chillers are equipped with comprehensive multi-layer protection including: high/low voltage protection, phase sequence protection, overload protection, oil pressure differential protection, oil temperature protection, medium liquid level monitoring, antifreeze protection, exhaust temperature protection, and safety valve protection, ensuring safe and reliable continuous operation.
Can the chiller be integrated with building management or industrial control systems?
Yes. The units feature an industrial-grade Siemens PLC control system with a color LCD touch screen, and support remote communication interfaces including Modbus (RTU/TCP) and BACnet, enabling seamless integration with SCADA, BMS, and other industrial automation platforms.
What industries and applications are these chillers most suitable for?
These chillers are designed for a broad range of industrial applications, including plastic injection molding & extrusion, die-casting, automotive manufacturing, chemical & pharmaceutical processing, food & beverage production, data centers, central air conditioning systems, and shipbuilding. Any application requiring stable, continuous, and high-capacity process cooling can benefit from this solution.