Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
1. Standard Temperature Type
Outlet Temperature: Typically > 5°C
Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
2. Low-Temperature Type
Outlet Temperature: Typically ranging from -20°C to +5°C
Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
3. Explosion-Proof Type
Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
4. Corrosion-Resistant Type
Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
1. Compressor
Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
2. Heat Exchangers (Evaporator / Condenser)
Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
3. Control System
Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
4. Protection Systems
Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍔
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×10⁴ kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power (kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp (A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power (kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current (A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Control Mode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power (kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current (A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head (m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length (mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width (mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height (mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume (L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight (kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
Products Detail
Frequently Asked Questions (FAQ)
What is the difference between a standard temperature and a low-temperature industrial water-cooled chiller?
A standard temperature chiller delivers outlet water above 5°C and is suitable for general industrial cooling such as injection molding and laser equipment. A low-temperature chiller operates between -20°C and +5°C using two-stage compression or cascade refrigeration cycles, making it ideal for pharmaceutical reactions, food quick-freezing, and low-temperature laboratory applications.
What type of compressor is used in industrial water-cooled chillers?
Industrial water-cooled chillers primarily use screw compressors for their stability, durability, and wide modulation range. Centrifugal compressors are used for very large capacities. Many units feature a multiple-compressor parallel design to ensure continued operation even if one compressor fails.
What refrigerants are used in these chillers?
The chillers use R22 refrigerant for most standard models, while select models such as the 25WS and 50WD utilize R410A refrigerant. Refrigerant flow is controlled via an External Balance Type Thermal Expansion Valve across all models.
Can the industrial water-cooled chiller be used in hazardous or corrosive environments?
Yes. The explosion-proof type is specifically engineered for environments with flammable gases or dust, such as petrochemical plants and painting workshops. The corrosion-resistant type features stainless steel or anti-corrosion material construction, making it suitable for electroplating shops, chemical plants, and offshore platforms.
What control and communication options are available?
The chillers support imported microcomputer or PLC control (optional), and feature RS485 communication for automatic management. Advanced models include touchscreen HMIs with remote monitoring, fault diagnosis, data logging, and energy management. Integration with SCADA and DCS production line systems is also supported.
What safety protections are built into the industrial water-cooled chiller?
These chillers are equipped with comprehensive protection systems including high/low pressure protection, overcurrent protection, oil pressure differential protection, freeze protection, low-flow protection, and phase protection. Fault display functionality allows for maintenance without the need for specialized personnel.