Leave Your Message

China Industrial Water Cooled Chiller Suppliers - High-Efficiency Cooling Solutions from Reliable Factory

Introducing our state-of-the-art industrial water-cooled chiller, meticulously designed for demanding environments in China. As a leading supplier of industrial cooling solutions, our chillers offer unparalleled precision in process cooling. With robust construction and high-efficiency components, these systems ensure reliable temperature control for various manufacturing processes. Whether you require standard or custom configurations, our factory is equipped to meet your specific operational needs, making us your go-to choice for industrial chiller solutions in the market.

    Product Feature

    Adopt compressor imported from Europe and America;

    The copper pipe adopts oxygen free welding method;

    RS485 communication function to realize automatic management (optional);

    Imported advanced components with long service life;

    Siemens, SCHNEIDER, LG, MOELLER, West is adopted for electrical appliances;

    Control mode: imported microcomputer or PLC control (optional);

    Perfect safety protection, fault display, repair and maintenance without professional personnel;

    High efficiency evaporator and condenser can save energy by more than 30%.

    Main Types

    Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:

    1. Standard Temperature Type
    • Outlet Temperature: Typically > 5°C
    • Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
    2. Low-Temperature Type
    • Outlet Temperature: Typically ranging from -20°C to +5°C
    • Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
    • Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
    3. Explosion-Proof Type
    • Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
    • Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
    4. Corrosion-Resistant Type
    • Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
    • Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.

    Key Components & Industrial-Grade Features

    Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:

    1. Compressor
    • Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
    • Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
    2. Heat Exchangers (Evaporator/Condenser)
    • Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
    • Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
    3. Control System
    • Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
    • Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
    4. Protection Systems
    • Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.

    Typical Industrial Applications

    • Plastics Industry: Cooling for injection molding machine molds, directly impacting product quality and cycle time.
    • Chemical & Pharmaceutical: Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
    • Machining & Lasers: Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
    • Food & Beverage: Cooling for mixing, fermentation, and packaging processes in production lines.
    • Electronics Industry: Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
    • Energy & Metallurgy: Transformer oil cooling, blast furnace auxiliary system cooling.
    16
    15
    14

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter Model 03WS 05WS 06WS 08WS 10WD 12WS 15WD 20WD 25WS 30WF 40WF 50WD
    Refrigeration Capacity kW 7.7 14.2 8.98 18.95 28.4 33.5 37.9 58.2 67 75.8 116.4 135.6
    ×10⁴kcal/hr 0.66 1.22 1.45 1.63 2.44 2.88 3.26 5 5.76 6.52 10.01 11.66
    Consumed Power(kW) 2.49 3.81 4.29 5.29 7.62 8.78 10.98 15.34 17.95 21.96 30.28 35.50
    Running Amp(A) 4.73 7.79 7.76 10.9 15.58 17.1 22.6 32.38 33.26 45.2 64.06 65.82
    Compressor Number 1 1 1 1 2 1 2 2 1 4 4 2
    Power(kW) 1.94 3.26 3.74 4.74 6.52 7.68 9.48 13.14 15.75 18.96 26.28 31.5
    Current(A) 3.63 6.69 6.66 9.80 13.38 14.90 19.6 27.98 28.86 39.2 55.96 57.72
    Refrigerant Type R22 R410A R22 R410A
    Controlmode External Balance Type Thermal Expansion Valve
    Pump Type High-Efficiency Low-Noise Centrifugal Pump
    Power(kW) 0.55 0.55 0.55 0.55 1.1 1.1 1.5 2.2 2.2 3 4 4
    Current(A) 1.1 1.1 1.1 1.1 2.2 2.2 3 4.4 4.4 6 8.1 8.1
    Head(m) 22 21 21 20.5 25.5 24.5 23.5 27.5 27 33 29 29
    Condenser Water Pipe DN25 DN40 DN50 DN65
    WaterFlowRate(m³/h) 1.73 3.11 3.70 4.25 6.22 7.32 8.51 12.74 14.99 17.01 25.47 29.99
    Evaporator Water Pipe DN25 DN40 - DN50 DN65
    WaterFlowRate(m³/h) 1.40 2.55 3.06 3.44 5.10 5.99 6.87 10.47 12.28 13.75 20.95 24.56
    Size Length(mm) 900 900 900 1300 1300 1450 1450 1800 1800 2200 2500 2500
    Width(mm) 650 650 650 800 800 900 900 1000 1000 1350 1350 1350
    Height(mm) 1090 1090 1090 1750 1750 1750 1750 1800 1800 1400 1800 1800
    Tank Volume(L) 50 75 90 120 120 160 160 250 300 300 500 500
    Total Weight(kg) 150 220 260 310 360 450 650 850 1050 1250 1350 1400

    Products Detail

    Industrial Water Cooled Chiller (1)
    Industrial Water Cooled Chiller (4)
    Industrial Water Cooled Chiller (2)
    Industrial Water Cooled Chiller (3)

    Frequently Asked Questions

    Q What is the primary difference between standard and low-temperature water-cooled chillers?
    Standard temperature chillers typically provide outlet water above 5°C for general processes like plastic injection and laser cooling. Low-temperature units operate between -20°C and +5°C, using multi-stage or cascade systems with specialized refrigerants for applications like pharmaceutical reaction vessels and food quick-freezing.
    Q How does the multi-compressor parallel design benefit operation?
    Multiple parallel compressors provide operational redundancy and stepped capacity control. If one compressor requires servicing or fails, the remaining units continue running, preventing unexpected and costly production shutdowns.
    Q Can these chillers be integrated into central industrial control systems?
    Yes. With optional RS485 communication protocols and microcomputer/PLC controllers, the chillers seamlessly connect to centralized SCADA or DCS network architectures for remote monitoring, parameter logging, and automated control.
    Q What options are available for corrosive working environments?
    For corrosive or coastal environments, corrosion-resistant models are built with stainless steel or titanium heat exchanger tubes, anti-corrosive casing, and protective piping treatments to ensure long-term durability against harsh chemicals or seawater.
    Q How do high-efficiency heat exchangers reduce operating costs?
    By optimizing thermal transfer surfaces and utilizing oversized shell-and-tube designs with high fouling allowances, these evaporators and condensers enhance thermal efficiency, resulting in energy savings of over 30%.