0102030405
China Industrial Water Cooled Chiller Suppliers | High-Efficiency Cooling Solutions from Leading Factory
Product Features
Adopt compressor imported from Europe and America.
The copper pipe adopts oxygen-free welding method.
RS485 communication function to realize automatic management (optional).
Imported advanced components with long service life.
Siemens, SCHNEIDER, LG, MOELLER, West is adopted for electrical appliances.
Control mode: imported microcomputer or PLC control (optional).
Perfect safety protection, fault display, repair and maintenance without professional personnel.
High efficiency evaporator and condenser can save energy by more than 30%.
Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
1
Standard Temperature Type
• Outlet Temperature: Typically > 5°C
• Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
2
Low-Temperature Type
• Outlet Temperature: Typically ranging from -20°C to +5°C
• Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
• Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
3
Explosion-Proof Type
• Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
• Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
4
Corrosion-Resistant Type
• Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
• Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
1
Compressor
• Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
• Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
2
Heat Exchangers (Evaporator/Condenser)
• Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
• Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
3
Control System
• Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
• Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
4
Protection Systems
• Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
Typical Industrial Applications
Plastics Industry: Cooling for injection molding machine molds, directly impacting product quality and cycle time.
Chemical & Pharmaceutical: Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
Machining & Lasers: Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
Food & Beverage: Cooling for mixing, fermentation, and packaging processes in production lines.
Electronics Industry: Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
Energy & Metallurgy: Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter / Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×10⁴ kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power (kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp (A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power (kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current (A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Control Mode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power (kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current (A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head (m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length (mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width (mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height (mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume (L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight (kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
Products Detail
Frequently Asked Questions (FAQ)
Q1
What is the difference between standard and low-temperature water-cooled chillers?
Standard temperature chillers generally supply outlet water temperatures above 5°C, making them ideal for injection molding, laser cutting, and HVAC applications. Low-temperature chillers operate between -20°C and +5°C using two-stage compression or cascade refrigeration systems for pharmaceutical reactions, crystallization, and rapid freezing.
Q2
How does the multi-compressor design improve system reliability?
Models configured with dual or multiple compressors provide built-in redundancy. If one compressor requires servicing or faults out, the remaining compressors continue operating to prevent total production shutdown while providing flexible capacity modulation under varying cooling loads.
Q3
Can this industrial chiller connect to factory automation systems (SCADA / PLC)?
Yes. The chiller supports an optional RS485 communication interface and advanced microcomputer or PLC control architectures, enabling seamless remote monitoring, real-time data logging, fault alarms, and central DCS/SCADA integration.
Q4
When should an explosion-proof or corrosion-resistant model be selected?
Explosion-proof models are essential in hazardous environments containing flammable gases or volatile chemical dust (e.g., petrochemical plants, paint shops). Corrosion-resistant models with stainless steel or titanium heat exchangers are required in marine, electroplating, and chemical settings with high salinity or acid/alkaline vapors.
Q5
What safety and protection systems are built into these chillers?
The units are equipped with comprehensive protection systems, including high/low pressure switches, overcurrent protection, oil pressure differential protection, anti-freeze detection, water flow limit safeguards, and phase reverse/loss protection to ensure safe operation.
Q6
How does the unit achieve energy savings of over 30%?
Energy savings of 30%+ are achieved through high-efficiency European/American compressors, oversized shell-and-tube evaporators and condensers, oxygen-free welded copper circuits, and external balance thermal expansion valves that ensure precise refrigerant flow matching thermal loads.