0102030405
China Industrial Water Cooled Chiller Suppliers - Heavy-Duty Factory Refrigeration Solutions
⚙️ Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
🗂️ Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
🌡️1. Standard Temperature Type
- Outlet Temperature: Typically > 5°C
- Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
❄️2. Low-Temperature Type
- Outlet Temperature: Typically ranging from -20°C to +5°C
- Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
- Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
🔒3. Explosion-Proof Type
- Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
- Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
🛡️4. Corrosion-Resistant Type
- Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
- Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
🔧 Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
1. Compressor
- Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
- Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
2. Heat Exchangers (Evaporator / Condenser)
- Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
- Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
3. Control System
- Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
- Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
4. Protection Systems
- Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
🏭 Typical Industrial Applications
🧴
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔩
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🥤
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💻
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
📐 Schematic Diagram
📋 Specification
| Parameter Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×10⁴kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power (kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp (A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power (kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current (A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Control Mode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power (kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current (A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head (m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length (mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width (mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height (mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume (L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight (kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
🖼️ Products Detail
❓ Frequently Asked Questions
Q What is an industrial water-cooled chiller and how does it work?
An industrial water-cooled chiller is a refrigeration system that removes heat from process water using a refrigeration cycle. Warm process water enters the evaporator, where it transfers heat to the refrigerant. The refrigerant is then compressed and the heat is rejected through the condenser using a separate cooling water circuit (typically connected to a cooling tower). The chilled water is then recirculated to cool industrial equipment or processes.
Q What is the difference between a standard temperature and a low-temperature industrial chiller?
A standard temperature chiller typically delivers outlet water above 5°C, suitable for general industrial cooling such as injection molding or laser equipment. A low-temperature chiller can produce outlet water as low as -20°C, using two-stage compression or cascade refrigeration cycles with special low-temperature refrigerants. Low-temperature units are used in pharmaceutical, food quick-freezing, and chemical crystallization applications.
Q What refrigerants are used in these industrial water-cooled chillers?
The chillers in this range use R22 for most standard models and R410A for selected models (25WS and 50WD). The refrigerant flow is controlled via an External Balance Type Thermal Expansion Valve, ensuring precise and efficient refrigerant metering across all operating conditions.
Q What safety protection features are built into these chillers?
These industrial chillers are equipped with comprehensive protection systems including high/low pressure protection, overcurrent protection, oil pressure differential protection, freeze protection, low-flow protection, and phase protection. Fault codes are displayed on the control panel, allowing maintenance without requiring specialized technicians.
Q Can the chiller be integrated with a factory automation or SCADA system?
Yes. These chillers support RS485 communication (optional) and are equipped with advanced PLC control systems with touchscreen HMIs. They can communicate with SCADA, DCS, or other production line control systems, enabling remote monitoring, data logging, fault alerts, and precise energy management.
Q How do I select the right chiller model for my application?
Chiller selection depends on several factors: required cooling capacity (kW), desired outlet water temperature, process fluid type, available cooling water supply, installation space, and whether special features (explosion-proof, corrosion-resistant, low-temperature) are needed. Refer to the specification table for refrigeration capacity, power consumption, pump head, and unit dimensions for each model. Our technical team can assist with a customized selection based on your specific process requirements.