- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Main Types
Industrial water-cooled chillers are primarily categorized based on their outlet water temperature and specific applications:
1 Standard Temperature Type
- Outlet Temperature: Typically > 5°C
- Applications: Cooling for injection molding machines, extruders, die-casting machines, laser equipment, welding machines, and as primary cooling for central air-conditioning systems.
2 Low-Temperature Type
- Outlet Temperature: Typically ranging from -20°C to +5°C
- Features: Employs two-stage compression or cascade refrigeration cycles, utilizing low-temperature refrigerants.
- Applications: Cooling for pharmaceutical reaction kettles, chemical crystallization processes, food quick-freezing, low-temperature laboratories, and vacuum coating.
3 Explosion-Proof Type
- Features: All electrical components (motors, switches, controllers) are designed to be explosion-proof, preventing electrical sparks from igniting hazardous atmospheres.
- Applications: Used in locations with flammable gases or dust, such as petrochemical plants, coal mines, and painting workshops.
4 Corrosion-Resistant Type
- Features: The unit's casing, heat exchangers, piping, etc., are constructed from stainless steel or special anti-corrosion materials with specific surface treatments.
- Applications: Electroplating shops, chemical plants, offshore platforms, and environments with high salinity or humidity.
Key Components & Industrial-Grade Features
Beyond standard compressors, condensers, evaporators, and expansion devices, industrial chillers place special emphasis on:
1. Compressor
- Types: Heavy use of screw compressors (stable, durable, wide modulation range) and centrifugal compressors (for very large capacities). Some large low-temperature units employ cascade systems.
- Redundancy: Multiple compressor parallel design is common, ensuring continued operation if one fails.
2. Heat Exchangers (Evaporator / Condenser)
- Design: Often feature oversized shell-and-tube heat exchangers with larger fouling factor allowances.
- Materials: May use stainless steel tubes or titanium tubes (for seawater or highly corrosive cooling water).
3. Control System
- Intelligence: Advanced PLCs with touchscreen HMIs, featuring remote monitoring, fault, data logging, and energy management.
- Integration: Capable of communicating with primary production line control systems (e.g., SCADA, DCS) for control and precise regulation.
4. Protection Systems
- Comprehensive: Includes not only standard high/low pressure and overcurrent protection, but also oil pressure differential protection, freeze protection, low-flow protection, phase protection, etc., ensuring safe operation under harsh conditions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍔
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
⚠️ All specifications are for reference only. Actual parameters may vary by configuration. Please contact us for customized solutions.
| Parameter Model | 03WS | 05WS | 06WS | 08WS | 10WD | 12WS | 15WD | 20WD | 25WS | 30WF | 40WF | 50WD | |
| Refrigeration Capacity | kW | 7.7 | 14.2 | 8.98 | 18.95 | 28.4 | 33.5 | 37.9 | 58.2 | 67 | 75.8 | 116.4 | 135.6 |
| ×10⁴kcal/hr | 0.66 | 1.22 | 1.45 | 1.63 | 2.44 | 2.88 | 3.26 | 5 | 5.76 | 6.52 | 10.01 | 11.66 | |
| Consumed Power (kW) | 2.49 | 3.81 | 4.29 | 5.29 | 7.62 | 8.78 | 10.98 | 15.34 | 17.95 | 21.96 | 30.28 | 35.50 | |
| Running Amp (A) | 4.73 | 7.79 | 7.76 | 10.9 | 15.58 | 17.1 | 22.6 | 32.38 | 33.26 | 45.2 | 64.06 | 65.82 | |
| Compressor | Number | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 4 | 4 | 2 |
| Power (kW) | 1.94 | 3.26 | 3.74 | 4.74 | 6.52 | 7.68 | 9.48 | 13.14 | 15.75 | 18.96 | 26.28 | 31.5 | |
| Current (A) | 3.63 | 6.69 | 6.66 | 9.80 | 13.38 | 14.90 | 19.6 | 27.98 | 28.86 | 39.2 | 55.96 | 57.72 | |
| Refrigerant | Type | R22 | R410A | R22 | R410A | ||||||||
| Control Mode | External Balance Type Thermal Expansion Valve | ||||||||||||
| Pump | Type | High-Efficiency Low-Noise Centrifugal Pump | |||||||||||
| Power (kW) | 0.55 | 0.55 | 0.55 | 0.55 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4 | |
| Current (A) | 1.1 | 1.1 | 1.1 | 1.1 | 2.2 | 2.2 | 3 | 4.4 | 4.4 | 6 | 8.1 | 8.1 | |
| Head (m) | 22 | 21 | 21 | 20.5 | 25.5 | 24.5 | 23.5 | 27.5 | 27 | 33 | 29 | 29 | |
| Condenser | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.73 | 3.11 | 3.70 | 4.25 | 6.22 | 7.32 | 8.51 | 12.74 | 14.99 | 17.01 | 25.47 | 29.99 | |
| Evaporator | Water Pipe | DN25 | DN40 | DN50 | DN65 | ||||||||
| Water Flow Rate (m³/h) | 1.40 | 2.55 | 3.06 | 3.44 | 5.10 | 5.99 | 6.87 | 10.47 | 12.28 | 13.75 | 20.95 | 24.56 | |
| Size | Length (mm) | 900 | 900 | 900 | 1300 | 1300 | 1450 | 1450 | 1800 | 1800 | 2200 | 2500 | 2500 |
| Width (mm) | 650 | 650 | 650 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1350 | 1350 | 1350 | |
| Height (mm) | 1090 | 1090 | 1090 | 1750 | 1750 | 1750 | 1750 | 1800 | 1800 | 1400 | 1800 | 1800 | |
| Tank Volume (L) | 50 | 75 | 90 | 120 | 120 | 160 | 160 | 250 | 300 | 300 | 500 | 500 | |
| Total Weight (kg) | 150 | 220 | 260 | 310 | 360 | 450 | 650 | 850 | 1050 | 1250 | 1350 | 1400 | |
Products Detail
Frequently Asked Questions (FAQ)
Q What is the difference between a standard temperature chiller and a low-temperature chiller?
A standard temperature chiller typically provides outlet water above 5°C and is suitable for general industrial cooling such as injection molding and laser equipment. A low-temperature chiller operates between -20°C and +5°C using two-stage compression or cascade refrigeration cycles, making it ideal for pharmaceutical processes, food quick-freezing, and low-temperature laboratories.
Q What refrigerants are used in these industrial water-cooled chillers?
Most models use R22 refrigerant, while certain models (such as the 25WS and 50WD) use R410A refrigerant. The refrigerant control mode uses an External Balance Type Thermal Expansion Valve across all models.
Q Can the chiller be integrated with our existing production line control system?
Yes. The control system supports RS485 communication and advanced PLC with touchscreen HMI. It is capable of integrating with SCADA, DCS, and other primary production line control systems for remote monitoring, fault logging, and precise energy management.
Q Is there an explosion-proof version available for hazardous environments?
Yes. The Explosion-Proof Type chiller features all electrical components — including motors, switches, and controllers — designed to prevent electrical sparks from igniting hazardous atmospheres. It is suitable for petrochemical plants, coal mines, and painting workshops where flammable gases or dust may be present.
Q What safety protection features are included in the industrial chiller?
The chiller includes a comprehensive protection system covering high/low pressure protection, overcurrent protection, oil pressure differential protection, freeze protection, low-flow protection, and phase protection. These features ensure safe and reliable operation even under harsh industrial conditions.
Q How much energy can be saved compared to conventional chillers?
Thanks to the high-efficiency evaporator and condenser design, these industrial water-cooled chillers can achieve energy savings of more than 30% compared to conventional equipment, significantly reducing long-term operating costs.