Leave Your Message

China Combined Heating and Cooling Machines: Reliable Temperature Control Solutions from Leading Suppliers and Factory

Introducing our advanced hot and cold unit, an integrated thermal circulator designed for precise temperature control. This state-of-the-art device combines refrigeration and heating functions in one seamless system, ensuring stable and accurate temperature management. Ideal for use in laboratories and industrial processes, it effectively regulates the temperature of reactors, instruments, and testing chambers. As leading suppliers in China, our factory is committed to delivering high-quality temperature control solutions tailored to meet your specific needs. Experience reliability and efficiency with our hot and cold units, designed to enhance your operational performance

    Product Description

    Temperature Range: -50℃ ~ 300℃  |  Heating Power: 6KW – 96KW  |  Cooling Power: 3KW – 200

    Basic Functions

    🔥 Heating Part
    • Return oil temperature display
    • Start up automatic exhaust
    • Heating power gear adjustment
    • 304 stainless steel integrated pipe — reduces pipe resistance and carbon deposition
    • Perfect safety protection and fault display system — no professional personnel needed for repair and maintenance
    • PLC control — high reliability, strong anti-interference ability
    ❄️ Cooling Part
    • Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
    • Internal copper pipe welded without oxygen
    • High efficiency evaporator and condenser
    • 304 SS stainless steel water tank
    • PC board self-optimized microprocessor — easy to operate
    • OMRON, FUJI, TE, LG, AB, SCHNEIDER, SIEMENS and other brand accessories

    Core Working Principle

    Its operation is based on a closed-loop circulation system:

    1
    Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
    2
    Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
    3
    Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
    4
    Temperature Regulation:
    • When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    • When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
    5
    Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often±0.1°C or better.
    ⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages

    🏗️1. Integrated Design, Saves Space

    Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing ping connections.

    🌡️2. Broad Temperature Control Range

    A single unit covers a wide span from low to high temperatures. Common ranges: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.

    🎯3. High-Precision Temperature Control

    Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.

    ⚡4. High Efficiency and Energy Saving

    The cooling system operates at full capacity for fast cooling. During stabilization, it can run at lower power to offset process heat. Advanced models can recover waste heat from the refrigeration system for pre-heating.

    🚀5. Increases Production Efficiency

    Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields

    Industry / Field Specific Application Scenarios
    ⚗️ Chemical & Pharmaceutical Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    🏭 Plastics & Rubber Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    🔬 Laboratory & Testing Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    🔋 New Energy Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    💻 Semiconductor & Electronics Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    🍫 Food Industry Food production line temperature control, chocolatering, rapid cooling after can sterilization.
    🖨️ Other Industries Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
    Application 1
    Application 2
    Application 3

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter Unit Model
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃ – 300℃ 5℃ – 120℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dry Shell And Tube Type
    Condenser type / MCHE Or Fined Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m³/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size (L×W×H) mm 1200×1100×1250 1450×1250×1550 1200×1000×1250 1300×1180×1400 1200×1050×1250 1450×1200×1550 1200×950×1250 1300×1130×1400

    Products Detail

    Combined Heating and Cooling Machine 01
    Combined Heating and Cooling Machine 02
    Combined Heating and Cooling Machine 03

    Frequently Asked Questions (FAQ)

    Q  What is the temperature control range of this combined heating and cooling machine?
    The unit supports a temperature control range of -50°C to +300°C, depending on the model and heat transfer medium selected. Models using thermal oil can reach up to 300°C, while water-based models typically cover 5°C to 120°C. Common configurations include -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C.
    Q  What is the temperature control accuracy of this unit?
    The unit uses PID intelligent closed-loop control to achieve a temperature control accuracy of ±1°C standard, with high-precision models capable of reaching ±0.1°C or better. This makes it suitable for stringent laboratory and industrial process requirements.
    Q  What heat transfer mediums are compatible with this system?
    The system supports multiple heat transfer mediums depending on the model: thermally conductive oil (for high-temperature models up to 300°C) and water or glycol-water mixtures (for water-based models). The choice of medium affects the temperature range, cooling method (indirect vs. direct), and pipe connection specifications.
    Q  What industries and applications is this machine suitable for?
    This combined heating and cooling machine is widely used across multiple industries, including Chemical & Pharmaceutical (reaction kettles, bioreactors), Plastics & Rubber (injection molds, extruders), Laboratory & Testing (rotary evaporators, environmental chambers), New Energy (battery and motor testing), Semiconductor & Electronics (laser and PCB equipment cooling), Food Industry (chocolate tempering, sterilization cooling), and more.
    Q  What safety protection features does the unit include?
    The unit is equipped with a comprehensive safety protection and fault display system, including alarms for: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The PLC-based control system ensures high reliability and strong anti-interference capability, and no professional technician is required for routine maintenance.
    Q  What are the available heating and cooling power options?
    The heating power ranges from 6KW to 96KW, and the cooling capacity ranges from 3KW to 200KW, covering a wide range of industrial process demands. Standard models in the SCR series offer heating powers of 24KW or 36KW, with cooling capacities ranging from approximately 13.95KW to 31.8KW. Custom configurations are available for specific application requirements.