Leave Your Message

China Combined Heating and Cooling Machine - Top Suppliers & Factory for Precise Temperature Control Solutions

,

Introducing our advanced hot and cold unit, also known as a thermal circulator, designed for precise temperature control in various applications. This integrated device combines both refrigeration and heating functionalities within a compact system, ensuring stable and accurate temperature management. Ideal for laboratories and industrial processes, our thermal circulator effectively regulates the temperature of reactors, instruments, and testing chambers. As a leading supplier in China, our factory is dedicated to delivering high-quality thermal solutions that meet the demands of modern industry.

,

    Product Description
    Temperature Range: -50℃ ~ 300℃
    Heating Power: 6KW – 96KW
    Cooling Power: 3KW – 200KW

    Basic Functions
    🔥 Heating Part
    • Return oil temperature display
    • Start up automatic exhaust
    • Heating power gear adjustment
    • 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
    • Perfect safety protection and fault display system — no professional personnel needed for repair and maintenance
    • PLC control: high reliability, strong anti-interference ability
    ❄️ Cooling Part
    • Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
    • Internal copper pipe welded without oxygen
    • High efficiency evaporator and condenser
    • 304 SS stainless steel water tank
    • PC board self-optimized microprocessor, easy to operate
    • Premium brand accessories: OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS

    Core Working Principle

    Its operation is based on a closed-loop circulation system:

    1. Circulating Medium
    The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
    2. Pumping
    A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
    3. Heat Exchange
    The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
    4. Temperature Regulation
    • When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    • When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
    5. Return and Feedback
    The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
    ⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages
    🏗️ 1. Integrated Design, Saves Space
    Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
    🌡️ 2. Broad Temperature Control Range
    A single unit covers a wide span from low to high temperatures:
    • -80°C to +200°C
    • -40°C to +200°C
    • -25°C to +200°C
    • 0°C to +300°C
    🎯 3. High-Precision Temperature Control
    Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
    ⚡ 4. High Efficiency and Energy Saving
    • Refrigeration Power Utilization: Cooling system operates at full capacity for fast cooling; runs at lower power during stabilization for greater efficiency.
    • Heat Management: Advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
    🚀 5. Increases Production Efficiency
    Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields
    • ⚗️Chemical & Pharmaceutical: Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    • 🏭Plastics & Rubber: Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    • 🔬Laboratory & Testing: Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    • 🔋New Energy: Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    • 💻Semiconductor & Electronics: Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    • 🍫Food Industry: Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
    • 🖨️Other Industries: Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
    16
    15
    14

    Schematic Diagram
    Schematic Diagram

    Specification
    Parameter UNIT MODEL
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃-300℃ 5℃-120℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dny Shell And Tube Type
    Condenser type / MCHE Or Finned Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m³/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size (L×W×H) mm 1200×1100×1250 1450×1250×1550 1200×1000×1250 1300×1180×1400 1200×1050×1250 1450×1200×1550 1200×950×1250 1300×1130×1400

    Products Detail
    Combined Heating and Cooling Machine 01
    Combined Heating and Cooling Machine 02
    Combined Heating and Cooling Machine 03

    Frequently Asked Questions (FAQ)
    QWhat is the temperature control range of this combined heating and cooling machine?
    The unit supports a wide temperature control range from -50°C to 300°C, depending on the selected model and heat transfer medium. Oil-based models typically cover 5°C–300°C, while water-based models cover 5°C–120°C.
    QWhat heat transfer fluids are compatible with this unit?
    The unit is compatible with thermal conductive oil (for high-temperature oil models) and water (for water-based models). For sub-zero applications, a glycol-water mixture may also be used.
    QWhat is the temperature control accuracy of this machine?
    The unit uses PID intelligent control with a standard accuracy of ±1°C. Advanced configurations can achieve precision as tight as ±0.1°C, making it suitable for highly sensitive industrial and laboratory applications.
    QWhat industries and applications is this combined unit suitable for?
    This machine is widely used across Chemical & Pharmaceutical, Plastics & Rubber, Laboratory & Testing, New Energy (battery/motor testing), Semiconductor & Electronics, Food Industry, and other fields requiring precise and rapid temperature control of process equipment.
    QWhat safety protection features does the unit include?
    The machine is equipped with a comprehensive alarm and protection system covering: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The fault display system allows operators to identify and respond to issues without requiring specialized maintenance personnel.
    QWhat is the power supply requirement, and what heating/cooling power options are available?
    All models operate on AC 380V / 50Hz. Heating power ranges from 6KW to 96KW, and cooling capacity ranges from 3KW to 200KW, with specific values varying by model (e.g., 24KW or 36KW heating; 13.95KW to 31.8KW cooling in standard configurations).