0102030405
China Combined Heating and Cooling Machine Suppliers | High-Quality Thermal Circulator from Factory
Product Description
🌡️
Temperature Range
-50℃ ~ 300℃
🔥
Heating Power
6 KW ~ 96 KW
❄️
Cooling Power
3 KW ~ 200 KW
Basic Functions
🔥 Heating Part
Return oil temperature display
Start up automatic exhaust
Heating power gear adjustment
Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
PLC control, high reliability, strong anti-interference ability
❄️ Cooling Part
Using brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
Internal copper pipe welded without oxygen
High efficiency evaporator and condenser
304 SS stainless steel water tank
PC board self-optimized microprocessor, easy to operate
OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories. Perfect safety.
Core Working Principle
Its operation is based on a closed-loop circulation system:
1
Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
2
Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
3
Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
4
Temperature Regulation:
When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
5
Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
💡
Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
🏗️
1. Integrated Design, Saves Space
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
🌡️
2. Broad Temperature Control Range
A single unit can cover a wide span from low to high temperatures. Common ranges include:
-80°C ~ +200°C
-40°C ~ +200°C
-25°C ~ +200°C
0°C ~ +300°C
🎯
3. High-Precision Temperature Control
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
⚡
4. High Efficiency and Energy Saving
Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During stabilization, it can run at lower power to offset process heat more efficiently.
Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
🚀
5. Increases Production Efficiency
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
Chemical & Pharmaceutical
Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
Plastics & Rubber
Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
Laboratory & Testing
Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
New Energy
Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
Semiconductor & Electronics
Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
Food Industry
Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
Other Industries
Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
📋 Technical Parameters — Model Comparison Table
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dry Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200×1100×1250 | 1450×1250×1550 | 1200×1000×1250 | 1300×1180×1400 | 1200×1050×1250 | 1450×1200×1550 | 1200×950×1250 | 1300×1130×1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the temperature control range of this combined heating and cooling machine?
The unit supports a temperature range of -50°C to 300°C. Common configurations include -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C, making it suitable for a wide variety of industrial processes.
Q
What heat transfer media can be used with this unit?
Depending on the model, the unit supports water, glycol-water mixtures, or thermal conductive oil as the circulating heat transfer medium. Oil-based models (O-series) are suited for high-temperature applications up to 300°C, while water-based models (W-series) are ideal for processes up to 120°C.
Q
What level of temperature control accuracy can this machine achieve?
The system uses PID intelligent control logic to achieve temperature control accuracy of ±1°C (standard) and can reach ±0.1°C or better in precision configurations. This makes it ideal for sensitive chemical reactions, pharmaceutical processes, and laboratory testing.
Q
What industries and applications is this unit suitable for?
This combined unit is widely used across chemical and pharmaceutical industries (reactor temperature control), plastics and rubber (mold temperature control), laboratory and testing (rotary evaporators, calorimeters), new energy (battery thermal testing), semiconductor and electronics (laser cooling, PCB equipment), food industry, and more.
Q
Does the unit require professional technicians for maintenance?
No. The unit is equipped with a perfect safety protection and fault display system that clearly indicates any fault conditions. Combined with PLC control and brand-name components (OMRON, SIEMENS, ABB, SCHNEIDER, etc.), routine maintenance does not require specialized personnel.
Q
What safety alarm functions are built into the system?
The unit includes a comprehensive alarm system covering: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. These protections ensure safe and stable long-term operation in demanding industrial environments.