Leave Your Message

China Combined Heating and Cooling Machine Suppliers - Advanced Thermal Circulator Factory for Precise Temperature Control

A hot and cold unit, also known as a thermal circulator, is an advanced integrated temperature control device widely utilized in laboratories and industrial processes. This innovative system combines both refrigeration and heating capabilities, ensuring precise and stable temperature management for reactors, instruments, and testing chambers. As a leading supplier in China, our factory specializes in manufacturing high-quality thermal circulators that meet the diverse needs of various industries. Whether for research or production, our reliable temperature control solutions are designed to optimize performance and efficiency.

    Product Description

    Temperature Range: -50℃ to 300℃
    Power Range: Heating Power 6KW–96KW, Cooling Power 3KW–200KW

    Basic Functions

    Heating Part
    • Return oil temperature display
    • Start up automatic exhaust
    • Heating power gear adjustment
    • Adopt 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
    • Perfect safety protection and fault display system, no professional personnel needed for repair and maintenance
    • PLC control, high reliability, strong anti-interference ability
    Cooling Part
    • Using brand scroll compressor, grain wheel, Sanyo, Daikin, etc.
    • The internal copper pipe is welded without oxygen
    • High efficiency evaporator and condenser
    • 304 SS stainless steel water tank
    • PC board self-optimized microprocessor, easy to operate
    • OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories, perfect safety

    Core Working Principle

    Its operation is based on a closed-loop circulation system:

    1. Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
    2. Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
    3. Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
    4. Temperature Regulation:
    • When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    • When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
    5. Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within a high precision, often ±0.1°C or better.
    Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages

    1. Integrated Design, Saves Space: Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
    2. Broad Temperature Control Range: A single unit can cover a wide span from low temperatures (e.g., -80°C) to high temperatures (e.g., +200°C). Common ranges include: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
    3. High-Precision Temperature Control: Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
    4. High Efficiency and Energy Saving:
    • Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at a lower power to offset it, which is more efficient than cooling alone.
    • Heat Management: Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
    5. Increases Production Efficiency: Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields

    • Field: Specific Application Scenarios

    • Chemical & Pharmaceutical: Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    • Plastics & Rubber: Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    • Laboratory & Testing: Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    • New Energy: Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    • Semiconductor & Electronics: Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    • Food Industry: Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
    • Other Industries: Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.

    Schematic Diagram

    Schematic Diagram

    Specification

    Parameter UNIT MODEL
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃-300℃ 5℃-120℃
    Temp control accuracy ℃ PID±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal/Oil shortage/Overheating/Overload/Oil overflow/Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dny Shell And Tube Type
    Condenser type / MCHE Or Finned Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m3/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size(LxWxH) mm 1200*1100*1250 1450*1250*1550 1200*1000*1250 1300*1180*1400 1200*1050*1250 1450*1200*1550 1200*950*1250 1300*1130*1400

    Products Detail

    Frequently Asked Questions

    What temperature range does this combined machine cover?
    The equipment covers a wide temperature range between -50℃ and 300℃, with models supporting specific spans such as 5℃ to 300℃ (thermal oil) and 5℃ to 120℃ (water).
    What heat transfer media are supported?
    Depending on the model and required operating temperature range, water, a glycol-water mixture, or thermo conductive oil can be utilized.
    How does the unit maintain high temperature control precision?
    It uses an intelligent PID logic control system that continuously compares real-time fluid return temperatures against set points, achieving rapid heating/cooling adjustments with PID ±1℃ precision.
    What safety and alarm protections are included?
    The unit includes comprehensive fault alarms for pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating, all managed via PLC control for easy operation.
    What are the advantages of an integrated heating and cooling system?